Intra and inter-rater reliability of skin fold measurements in university men

被引:0
|
作者
de Oliveira Filho, Aluizio Picanco [1 ]
de Brito, Alex Lima [1 ]
Viana, Albert da Silva [1 ]
de Sousa de Lima Deniur, Jose Rodrigo [1 ]
de Azevedo Albuquerque, Ana Paula [1 ]
Pureza, Demilto Yamaguchida [1 ]
Materko, Wollner [1 ]
机构
[1] Univ Fed Amapa UNIFAP, Escola Educ Fis, Lab Biodinam Movimento Humano, Macapa, AP, Brazil
来源
关键词
Inter-rater; Skin folds; Intra-rater; Reliability;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the present study was to compare the intra and inter-rater reliability of skin fold thickness pectoral (STP), abdomen (STA) and thigh (STT) in university men. It was a sample of 17 men (18 until 41 years old) and physically active. All volunteers were submitted to an anthropometric evaluation and measurement of the three skin folds by a same evaluator to study the intra-rater reliability through Anova by repetitive measures and Bonferroni pos hoc test and the intra-rater reliability based in the value of the mean of the three measures for each skin fold by Anova one-way and the Tukey post hoc test. All tests assumed = 0.05. The results of the skin fold values obtained for the same evaluator in three attempts in STP (12.0 +/- 1.7 mm, 12.0 +/- 1.6 mm and 11.9 +/- 1.6 mm), STA (21, 7 +/- 2.5 mm, 20.4 +/- 2.5 mm and 20.3 +/- 2.4 mm) and STT (15.0 +/- 1.6 mm, 15.4 +/- 1.7 mm and 14.7 +/- 1.5 mm), showing no significant difference in all skin folds. When comparing the results mean difference between the evaluators of 1.2 mm, 1.4 mm and 0.4 mm, respectively, for STP, STA and STT, no showing significant difference. In conclusion, the results in the comparison of skin fold measurements in the intra-rater and inter-rater evaluation, a high correlation (r = 0.91-0.99, p < 0.01) could be observed for all skin folds. In conclusion, the results of the present study showed a good intra-rater reliability and inter-rater in the measurements of skin folds in university men.
引用
收藏
页码:1079 / 1085
页数:7
相关论文
共 50 条
  • [31] Intra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system
    Maynard, V
    Bakheit, AMO
    Oldham, J
    Freeman, J
    GAIT & POSTURE, 2003, 17 (01) : 59 - 67
  • [32] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [33] Introducing a new definition of a near fall: Intra-rater and inter-rater reliability
    Maidan, I.
    Freedman, T.
    Tzemah, R.
    Giladi, N.
    Mirelman, A.
    Hausdorff, J. M.
    GAIT & POSTURE, 2014, 39 (01) : 645 - 647
  • [34] A study to investigate the intra-rater and inter-rater reliability of goniometric measurements of dart throwers motion of asymptomatic wrists
    Cliff, Nicola J.
    Rust, Philippa A.
    HAND THERAPY, 2016, 21 (02) : 58 - 64
  • [35] THE INTER-RATER AND INTRA-RATER RELIABILITY ANALYSIS OF WORKPLACE ERGONOMIC RISK ASSESSMENT
    Rohani, Jafri Mohd.
    Adeyemi, Ademola James
    Abd Aziz, Roseni
    Rani, Mat Rebi Abdul
    JURNAL TEKNOLOGI, 2018, 80 (01): : 53 - 59
  • [36] Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton
    Jennifer A. Semrau
    Troy M. Herter
    Stephen H. Scott
    Sean P. Dukelow
    Journal of NeuroEngineering and Rehabilitation, 14
  • [37] INTER-RATER RELIABILITY OF SONOGRAPHIC MEASUREMENTS OF THE INFERIOR VENA CAVA
    Saul, Turandot
    Lewiss, Resa E.
    Langsfeld, Alexis
    Radeos, Michael S.
    Del Rios, Marina
    JOURNAL OF EMERGENCY MEDICINE, 2012, 42 (05): : 600 - 605
  • [38] Comparison between Inter-rater Reliability and Inter-rater Agreement in Performance Assessment
    Liao, Shih Chieh
    Hunt, Elizabeth A.
    Chen, Walter
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2010, 39 (08) : 613 - 618
  • [39] Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography
    Dysli, Muriel
    Kanku, Madeleine
    Traber, Ghislaine L.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (04) : 420 - 423
  • [40] Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton
    Semrau, Jennifer A.
    Herter, Troy M.
    Scott, Stephen H.
    Dukelow, Sean P.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14