Comparison of standard T2-weighted turbo spin echo and volumetric interpolated breath-hold examination magnetic resonance imaging sequences in the assessment of articular process dysplasia in Pug dogs with thoracolumbar myelopathy

被引:1
|
作者
Gilbert, Emma [1 ]
Rose, Jeremy [1 ]
Arrol, Lorna [1 ]
Driver, Colin J. [1 ]
机构
[1] Lumbry Pk Vet Specialists, Neurol Dept, Alton, England
关键词
Pug dog; CAP dysplasia; VIBE sequence; thoracolumbar myelopathy; T2W turbo spin echo; MRI; GUIDES;
D O I
10.3389/fvets.2023.1265665
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
IntroductionA retrospective study to compare the classification, as normal, hypoplastic or aplastic, of thoracic (T10-T13) caudal articular process (CAP) morphology in Pug dogs with a thoracolumbar myelopathy as normal, hypoplastic or aplastic, between T2 weighted Turbo Spin Echo (T2W-TSE), in sagittal and transverse planes, and Volumetric Interpolated Breath-hold Examination (VIBE) Magnetic Resonance Imaging (MRI) sequences, in comparison to Computed Tomography (CT). We hypothesized a stronger agreement for VIBE in comparison to T2W-TSE.ResultsDiagnostic accuracy of T2W-TSE was inferior to VIBE for aplastic (60%, 95% CI 0.561-0.639 vs. 78%, 95%CI 0.744-0.815) hypoplastic (44%, 95%CI 0.427-0.452 vs. 62.5%, 95%CI 0.595-0.655) and normal CAP (70%, 95%CI 0.655-0.744 vs. 87%, 95%CI 0.848-0.892). Superior accuracy of classification using VIBE vs. T2W-TSE sequences using the McNemar Chi squared test was significant for aplastic (p = 0.0002) and normal CAP (p = 0.004). VIBE sequences had a sensitivity of 96% and specificity of 75% to detect CAP abnormality and with T2W-TSE imaging sensitivity 81% and specificity of 75%.DiscussionThree-dimensionally reconstructable VIBE sequences were significantly more accurate than traditional T2W-TSE MRI sequences in classifying CAP morphology, which should reduce the need for CT for pre-operative assessment.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    Soyer, P
    LeNormand, S
    deGivry, SC
    Gueye, C
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 593 - 597
  • [32] Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences
    Meindl, T.
    Wirth, S.
    Weckbach, S.
    Dietrich, O.
    Reiser, M.
    Schoenberg, S. O.
    EUROPEAN RADIOLOGY, 2009, 19 (03) : 713 - 721
  • [33] Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences
    T. Meindl
    S. Wirth
    S. Weckbach
    O. Dietrich
    M. Reiser
    S. O. Schoenberg
    European Radiology, 2009, 19 : 713 - 721
  • [34] Detection of focal fiver lesions in unenhanced and ferucarbotran-enhanced magnetic resonance imaging: a comparison of T2-weighted breath-hold and respiratory-triggered sequences
    Rief, Matthias
    Wagner, Moritz
    Franiel, Tobias
    Bresan, Viola
    Taupitz, Matthias
    Klessen, Christian
    Hamm, Bernd
    Asbach, Patrick
    MAGNETIC RESONANCE IMAGING, 2009, 27 (09) : 1223 - 1229
  • [35] Fat-suppressed T2-weighted MRI of the liver: Comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Takahashi, M
    Sakahara, H
    Nozaki, A
    Kabasawa, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 439 - 449
  • [36] Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity
    Vogt, FM
    Antoch, G
    Hunold, P
    Maderwald, S
    Ladd, ME
    Debatin, JF
    Ruehm, SG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) : 376 - 382
  • [37] Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
    Tanabe, Masahiro
    Kawano, Yosuke
    Ihara, Kenichiro
    Miyoshi, Keisuke
    Ishii, Jo
    Nomura, Kanako
    Morooka, Ryoko
    Higashi, Mayumi
    Ito, Katsuyoshi
    ABDOMINAL RADIOLOGY, 2024, : 2312 - 2320
  • [38] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [40] Non-Contrast-Enhanced Magnetic Resonance Angiography Using T2-Weighted 3-Dimensional Fat-Suppressed Turbo Spin Echo (SPACE): Diagnostic Performance and Comparison With Contrast-Enhanced Magnetic Resonance Angiography Using Volume Interpolated Breath-Hold Examination in the Detection of Portosystemic and Portohepatic Collaterals
    Song, Qiong
    Zeng, Mengsu
    Chen, Caizhong
    Ma, Jing
    Yun, Hong
    Rao, Shengxiang
    Yao, Xiuzhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (06) : 675 - 680