IntroductionA retrospective study to compare the classification, as normal, hypoplastic or aplastic, of thoracic (T10-T13) caudal articular process (CAP) morphology in Pug dogs with a thoracolumbar myelopathy as normal, hypoplastic or aplastic, between T2 weighted Turbo Spin Echo (T2W-TSE), in sagittal and transverse planes, and Volumetric Interpolated Breath-hold Examination (VIBE) Magnetic Resonance Imaging (MRI) sequences, in comparison to Computed Tomography (CT). We hypothesized a stronger agreement for VIBE in comparison to T2W-TSE.ResultsDiagnostic accuracy of T2W-TSE was inferior to VIBE for aplastic (60%, 95% CI 0.561-0.639 vs. 78%, 95%CI 0.744-0.815) hypoplastic (44%, 95%CI 0.427-0.452 vs. 62.5%, 95%CI 0.595-0.655) and normal CAP (70%, 95%CI 0.655-0.744 vs. 87%, 95%CI 0.848-0.892). Superior accuracy of classification using VIBE vs. T2W-TSE sequences using the McNemar Chi squared test was significant for aplastic (p = 0.0002) and normal CAP (p = 0.004). VIBE sequences had a sensitivity of 96% and specificity of 75% to detect CAP abnormality and with T2W-TSE imaging sensitivity 81% and specificity of 75%.DiscussionThree-dimensionally reconstructable VIBE sequences were significantly more accurate than traditional T2W-TSE MRI sequences in classifying CAP morphology, which should reduce the need for CT for pre-operative assessment.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [2] Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE)
    Coates, GG
    Borrello, JA
    McFarland, EG
    Mirowitz, SA
    Brown, JJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 642 - 649
  • [3] T2-weighted breath-hold MRI of the liver at 1.0 T: Comparison of turbo spin-echo and HASTE sequences with and without fat suppression
    Kim, TK
    Lee, HJ
    Jang, HJ
    Kim, AY
    Han, JK
    Choi, BI
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1213 - 1218
  • [4] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    T. K. Kim
    W. C. Wang
    J. K. Han
    S. G. Cho
    B. I. Choi
    Abdominal Imaging, 1998, 23 : 422 - 426
  • [5] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    Kim, TK
    Wang, WC
    Han, JK
    Cho, SG
    Choi, BI
    ABDOMINAL IMAGING, 1998, 23 (04): : 422 - 426
  • [6] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    Lee, MG
    Jeong, YK
    Kim, JC
    Kang, EM
    Kim, PN
    Auh, YH
    Chien, D
    Laub, G
    ABDOMINAL IMAGING, 2000, 25 (01): : 93 - 99
  • [7] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    M.-G. Lee
    Y. K. Jeong
    J. C. Kim
    E. M. Kang
    P. N. Kim
    Y. H. Auh
    D. Chien
    G. Laub
    Abdominal Imaging, 2000, 25 : 93 - 99
  • [8] Recognition of sacroiliac joint structural lesions: Comparison of volumetric interpolated breath-hold examination (VIBE) sequences with different slice thicknesses to T1-weighted turbo-echo
    Xie, Ruyi
    Sun, Dong
    Morelli, John N.
    Yin, Cuilin
    Xiong, Yan
    Li, Xiaoming
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [9] COMPARISON OF RESPIRATORY-TRIGGERED T2-WEIGHTED TURBO SPIN-ECHO IMAGING VERSUS BREATH-HOLD T2-WEIGHTED TURBO SPIN-ECHO IMAGING: DISTINGUISHING BENIGN FROM MALIGNANT LIVER LESIONS IN PATIENTS WITH COLORECTAL CANCER
    Coenegrachts, K.
    ter Beek, L.
    Haspeslagh, M.
    Bipat, S.
    Stoker, J.
    Rigauts, H.
    JBR-BTR, 2009, 92 (04): : 195 - 201
  • [10] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437