Comparison of standard T2-weighted turbo spin echo and volumetric interpolated breath-hold examination magnetic resonance imaging sequences in the assessment of articular process dysplasia in Pug dogs with thoracolumbar myelopathy

被引:1
|
作者
Gilbert, Emma [1 ]
Rose, Jeremy [1 ]
Arrol, Lorna [1 ]
Driver, Colin J. [1 ]
机构
[1] Lumbry Pk Vet Specialists, Neurol Dept, Alton, England
关键词
Pug dog; CAP dysplasia; VIBE sequence; thoracolumbar myelopathy; T2W turbo spin echo; MRI; GUIDES;
D O I
10.3389/fvets.2023.1265665
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
IntroductionA retrospective study to compare the classification, as normal, hypoplastic or aplastic, of thoracic (T10-T13) caudal articular process (CAP) morphology in Pug dogs with a thoracolumbar myelopathy as normal, hypoplastic or aplastic, between T2 weighted Turbo Spin Echo (T2W-TSE), in sagittal and transverse planes, and Volumetric Interpolated Breath-hold Examination (VIBE) Magnetic Resonance Imaging (MRI) sequences, in comparison to Computed Tomography (CT). We hypothesized a stronger agreement for VIBE in comparison to T2W-TSE.ResultsDiagnostic accuracy of T2W-TSE was inferior to VIBE for aplastic (60%, 95% CI 0.561-0.639 vs. 78%, 95%CI 0.744-0.815) hypoplastic (44%, 95%CI 0.427-0.452 vs. 62.5%, 95%CI 0.595-0.655) and normal CAP (70%, 95%CI 0.655-0.744 vs. 87%, 95%CI 0.848-0.892). Superior accuracy of classification using VIBE vs. T2W-TSE sequences using the McNemar Chi squared test was significant for aplastic (p = 0.0002) and normal CAP (p = 0.004). VIBE sequences had a sensitivity of 96% and specificity of 75% to detect CAP abnormality and with T2W-TSE imaging sensitivity 81% and specificity of 75%.DiscussionThree-dimensionally reconstructable VIBE sequences were significantly more accurate than traditional T2W-TSE MRI sequences in classifying CAP morphology, which should reduce the need for CT for pre-operative assessment.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [22] Flip Angle for the Optimal T1-weighted Image in the 3-D Volumetric Interpolated Breath-hold Examination Abdominal Magnetic Resonance Imaging Technique
    Goo, Eun-Hoe
    Kweon, Dae Cheol
    Dong, Kyung-Rae
    Lee, Jae-Seung
    Chung, Woon-Kwan
    Choi, Jiwon
    Lee, Jong-Woong
    Choe, Chong-Hwan
    APPLIED MAGNETIC RESONANCE, 2011, 40 (02) : 221 - 229
  • [23] Flip Angle for the Optimal T1-weighted Image in the 3-D Volumetric Interpolated Breath-hold Examination Abdominal Magnetic Resonance Imaging Technique
    Eun-Hoe Goo
    Dae Cheol Kweon
    Kyung-Rae Dong
    Jae-Seung Lee
    Woon-Kwan Chung
    Jiwon Choi
    Jong-Woong Lee
    Chong-Hwan Choe
    Applied Magnetic Resonance, 2011, 40 : 221 - 229
  • [24] T2-weighted MR imaging of hepatic hemangiomas: Comparison of breath-hold and conventional turbo SE pulse sequences with the phased-array coil
    Choi, BI
    Wang, WC
    Kim, TK
    Han, JK
    Han, MC
    RADIOLOGY, 1996, 201 : 476 - 476
  • [25] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [26] Breath-hold T2-weighted imaging of hepatic lesions by using fast recovery, fast spin-echo sequence
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Takamura, M
    Nakamura, H
    RADIOLOGY, 2001, 221 : 304 - 305
  • [27] Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors
    Kim, YK
    Kim, CS
    Chung, GH
    Bin Jeon, S
    Lee, JM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 497 - 504
  • [28] Fat-Suppressed 3D T1-Weighted Gradient-Echo Imaging of the Cartilage With a Volumetric Interpolated Breath-Hold Examination
    Zheng, Zhuo-Zhao
    Shan, Han
    Li, Xuan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W414 - W419
  • [29] Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breath-hold T2-weighted imaging
    Parikh, Tejas
    Drew, Stephen J.
    Lee, Vivian S.
    Wong, Samson
    Hecht, Elizabeth M.
    Babb, James S.
    Taouli, Bachir
    RADIOLOGY, 2008, 246 (03) : 812 - 822
  • [30] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859