Comparison of voltammetric methods used in the interrogation of electrochemical aptamer-based sensors

被引:6
|
作者
Verrinder, Elsi [1 ,4 ]
Leung, Kaylyn K. [1 ,4 ]
Erdal, Murat Kaan [5 ]
Sepunaru, Lior [1 ,2 ]
Plaxco, Kevin W. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Biomol Sci & Engn Grad Program, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biol Engn Grad Program, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[5] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
来源
SENSORS & DIAGNOSTICS | 2024年 / 3卷 / 01期
基金
美国国家卫生研究院;
关键词
RESOLVED MOLECULAR MEASUREMENTS; POLAROGRAPHY; REAGENTLESS;
D O I
10.1039/d3sd00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (EAB) sensors are the first continuous molecular measurement technology that is both (1) able to function in situ in the living body and (2) independent of the chemical reactivity of its targets, rendering it generalizable to a wide range of analytes. Comprised of an electrode-bound, redox-reporter-modified aptamer, signal generation in EAB sensors arises when binding to this target-recognizing aptamer causes a conformation change that, in turn, alters the rate of electron transfer to and from the redox reporter to the electrode surface. A range of electrochemical approaches, including both voltammetric (e.g., cyclic, square wave, and alternating current voltammetry) and non-voltammetric (e.g., chronoamperometry, electrochemical phase interrogation) methods have been used to monitor this change in transfer rate, with square wave voltammetry having dominated recent reports. To date, however, the literature has seen few direct comparisons of the performance of these various approaches. In response we describe here comparisons of EAB sensors interrogated using square wave, differential pulse, and alternating current voltammetry. We find that, while the noise associated with AC voltammetry (in vitro in 37 degrees C whole blood) is exceptionally low, neither this approach nor differential pulse voltammetry support accurate drift correction under these same conditions, suggesting that neither approach is suitable for deployment in vivo. Square wave voltammetry, in contrast, matches or surpasses the gain achieved by the other two approaches, achieves good signal-to-noise, and supports high-accuracy drift correction in 37 degrees C whole blood. Taken together, these results finally confirm that square wave voltammetry is the preferred pulsed voltammetric method for interrogating EAB sensors in complex biological fluids. Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [1] Single Voltammetric Sweep Calibration-Free Interrogation of Electrochemical Aptamer-Based Sensors Employing Continuous Square Wave Voltammetry
    Abeykoon, Sanduni W.
    White, Ryan J.
    ANALYTICAL CHEMISTRY, 2024, 96 (18) : 6958 - 6967
  • [2] Improved calibration of electrochemical aptamer-based sensors
    Alex M. Downs
    Julian Gerson
    Kaylyn K. Leung
    Kevin M. Honeywell
    Tod Kippin
    Kevin W. Plaxco
    Scientific Reports, 12
  • [3] Subsecond-Resolved Molecular Measurements Using Electrochemical Phase Interrogation of Aptamer-Based Sensors
    Downs, Alex M.
    Gerson, Julian
    Ploense, Kyle L.
    Plaxco, Kevin W.
    Dauphin-Ducharme, Philippe
    ANALYTICAL CHEMISTRY, 2020, 92 (20) : 14063 - 14068
  • [4] Improved calibration of electrochemical aptamer-based sensors
    Downs, Alex M.
    Gerson, Julian
    Leung, Kaylyn K.
    Honeywell, Kevin M.
    Kippin, Tod
    Plaxco, Kevin W.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Recent Advances in Electrochemical Aptamer-Based Sensors
    Ferapontova, Elena E.
    Gothelf, Kurt V.
    CURRENT ORGANIC CHEMISTRY, 2011, 15 (04) : 498 - 505
  • [6] Aptamer-Based Optical and Electrochemical Sensors: A Review
    Farid, Sidra
    Ghosh, Shreya
    Dutta, Mitra
    Stroscio, Michael A.
    CHEMOSENSORS, 2023, 11 (12)
  • [7] Engineering New Aptamer Geometries for Electrochemical Aptamer-Based Sensors
    White, Ryan J.
    Plaxco, Kevin W.
    BIO-INSPIRED/BIOMIMETIC SENSOR TECHNOLOGIES AND APPLICATIONS, 2009, 7321
  • [8] Fast interrogation of electrochemical, aptamer-based (E-AB) sensors for the characterization of small molecule-aptamer binding kinetics
    Cancel, Mirelis Santos
    Lazenby, Robert
    White, Ryan J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [9] Electrochemical and optical aptamer-based sensors for detection of tetracyclines
    Jalalian, Seyed Hamid
    Karimabadi, Niloofar
    Ramezani, Mohammad
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2018, 73 : 45 - 57
  • [10] Codeposition Enhances the Performance of Electrochemical Aptamer-Based Sensors
    Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara
    CA
    93106, United States
    不详
    CA
    93106, United States
    不详
    CA
    93106, United States
    不详
    CA
    93106, United States
    不详
    CA
    93106, United States
    Langmuir, 16 (8703-8710):