共 50 条
Comparison of the effect of pressure control and volume control ventilation on endotracheal tube cuff pressure in patients undergoing general anesthesia and mechanical ventilation: a parallel randomized clinical trial
被引:1
|作者:
Nasrolahzadeh, Shahram
[1
]
Nourian, Javad
[2
]
Khosravi, Ahmad
[3
]
Ghasempour, Saeed
[4
]
Abbasi, Ali
[5
]
Ebrahimi, Hossein
[6
]
机构:
[1] Shahroud Univ Med Sci, Imam Hossein Hosp, Shahroud, Iran
[2] Shahroud Univ Med Sci, Imam Hossein Hosp, Clin Res Dev Unit, Shahroud, Iran
[3] Shahroud Univ Med Sci, Ctr Hlth Related Social & Behav Sci Res, Dept Epidemiol, Shahroud, Iran
[4] Shahroud Univ Med Sci, Student Res Comm, Sch Nursing & Midwifery, Shahroud, Iran
[5] Shahroud Univ Med Sci, Sch Nursing & Midwifery, Dept Nursing, Shahroud, Iran
[6] Shahroud Univ Med Sci, Ctr Hlth Related Social & Behav Sci Res, Shahroud, Iran
关键词:
Volume control ventilation;
Pressure control ventilation;
Endotracheal tube cuff pressure;
Mechanical ventilation;
TIDAL VOLUMES;
BODY POSITION;
D O I:
10.1186/s12871-023-02263-1
中图分类号:
R614 [麻醉学];
学科分类号:
100217 ;
摘要:
Background Endotracheal intubation and mechanical ventilation are prevalent interventions in the operating room and intensive care unit. Recently, the complications of endotracheal tube cuff pressure have been a topic of interest. Therefore, this study compared the effect of pressure control and volume control ventilation modes on the endotracheal cuff pressure rate in patients undergoing general anesthesia and mechanical ventilation. Methods In this triple-blinded randomized clinical trial, 50 patients undergoing open limb surgery and inguinal hernia were allocated to two groups of 25 based on inclusion criteria. After intubation, one group underwent ventilation on the pressure control ventilation mode, and the other underwent ventilation on the volume control ventilation mode. In both groups, using a manometer, the cuff's pressure was first adjusted in the range of 25-30 cm of water. Then, the cuff pressure was measured at 10, 20, and 30 min intervals. The data were statistically analyzed using independent t-test, and two-way repeated measures ANOVA. Results The present study's findings showed that cuff pressure has significantly decreased over time in both study groups (F = 117.7, P < 0.001). However, a repeated measures ANOVA with a Greenhouse-Geisser correction showed no interaction between time and groups (F = 0.019, P = 0.98). The two groups had no significant difference in cuff pressure (F = 0.56, P = 0.458). Conclusion Since the cuff pressure has been significantly reduced in both groups over time, continuous monitoring of endotracheal tube cuff pressure in patients undergoing mechanical ventilation is essential. Therefore, it is suggested to keep the cuff pressure within the recommended range to prevent complications resulting from cuff pressure reduction, such as aspiration and ventilation decrease. Trial registration The study was registered in the Iranian Registry of Clinical Trial on 23/02/2019 (trial registration number: IRCT20181018041376N1).
引用
收藏
页数:7
相关论文