CUFF PRESSURE OF ENDOTRACHEAL TUBES AFTER CHANGES IN BODY POSITION IN CRITICALLY ILL PATIENTS TREATED WITH MECHANICAL VENTILATION

被引:73
|
作者
Lizy, Christelle [1 ]
Swinnen, Walter [2 ]
Labeau, Sonia [3 ]
Poelaert, Jan [4 ]
Vogelaers, Dirk [1 ]
Vandewoude, Koenraad [1 ]
Dulhunty, Joel [5 ,6 ]
Blot, Stijn [1 ]
机构
[1] Univ Ghent, Fac Med & Healthcare, Dept Internal Med, B-9000 Ghent, Belgium
[2] Gen Hosp Sint Blasius, Intens Care Unit, Dendermonde, Belgium
[3] Univ Coll Ghent, Fac Educ Hlth & Social Work, Ghent, Belgium
[4] Free Univ Brussels, Dept Anesthesiol, Brussels, Belgium
[5] Univ Queensland, Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[6] Univ Queensland, Burns Trauma & Crit Care Res Ctr, Brisbane, Qld, Australia
关键词
SUCTIONING TECHNIQUES; INTRACUFF PRESSURES; RISK-FACTORS; TRACHEAL; MANAGEMENT; PNEUMONIA; LESIONS; VOLUME; SCALE; SHAPE;
D O I
10.4037/ajcc2014489
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In order to avoid microaspiration and tracheal injury, the target for endotracheal tube cuff pressure is 20 to 30 cm H2O. Objective To assess the effect of changes in body position on cuff pressure in adult patients. Methods Twelve orally intubated and sedated patients received neuromuscular blockers and were positioned in a neutral starting position (backrest, head-of-bed elevation 30 degrees, head in neutral position) with cuff pressure at 25 cm H2O. Then, 16 changes in position were performed: anteflexion head, hyper extension head, left and right lateral flexion of head, left and right rotation of the head, semirecumbent position (head-of-bed elevation 45), recumbent position (head-of-bed elevation 10), horizontal backrest, Trendelenburg position (10), and left and right lateral positioning over 30, 45, and 90. Once a patient was correctly positioned, cuff pressure was recorded during an end-expiratory ventilatory hold. The pressure observed was compared with the cuff pressure at the starting position. Values outside the target range (20-30 cm H2O) were considered clinically relevant. Results A total of 192 measurements were performed (12 subjects x 16 positions). A significant deviation in cuff pressure occurred with all 16 changes (P < .05). No pressures were less than the lower limit (20 cm H2O). Pressures were greater than the upper limit (30 cm H2O) in 40.6% of the measurements. In each position, the upper target limit was exceeded at least once. Within-patient variability was substantial (P = .02). Conclusion Simple changes in patients' positioning can result in potentially harmful cuff pressures.
引用
收藏
页码:E1 / E8
页数:8
相关论文
共 50 条
  • [1] Relationship of Endotracheal Tube Cuff Pressures with Changes in Body Positions of Critically Ill Patients on Mechanical Ventilation: An Observational Study
    Roy, Oendrila
    Dasgupta, Sugata
    Chandra, Atanu
    Biswas, Puspendu
    Choudhury, Arpita
    Ghosh, Shrestha
    Chatterjee, Prithvijit
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2024, 28 (01) : 36 - 40
  • [2] Effect of patient position on endotracheal cuff pressure in mechanically ventilated critically ill patients
    Alcan, Aliye Okgun
    van Giersbergen, Meryem Yavuz
    Dincarslan, Gulin
    Hepcivici, Ziynet
    Kaya, Erdem
    Uyar, Mehmet
    AUSTRALIAN CRITICAL CARE, 2017, 30 (05) : 267 - 272
  • [3] Variations of endotracheal cuff pressure in intubated critically ill patients
    Nseir, Saad
    Brisson, Helene
    Marquette, Charles-Hugo
    Chaud, Pascal
    Durocher, Alain
    Di Pompeo, Christophe
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A148 - A148
  • [4] Effect of body position changes on endotracheal tube cuff pressure in ventilated patients
    C Lizy
    W Swinnen
    S Labeau
    S Blot
    Critical Care, 17 (Suppl 2):
  • [5] A NEW DEVICE TO REMOVE OBSTRUCTION FROM ENDOTRACHEAL-TUBES DURING MECHANICAL VENTILATION IN CRITICALLY ILL PATIENTS
    CONTI, G
    ROCCO, M
    DEBLASI, RA
    LAPPA, A
    ANTONELLI, M
    BUFI, M
    GASPARETTO, A
    INTENSIVE CARE MEDICINE, 1994, 20 (08) : 573 - 576
  • [6] COMPARISON OF TWO AUTOMATED ENDOTRACHEAL CUFF PRESSURE REGULATORS DEVICES IN INTUBATED CRITICALLY ILL PATIENTS: MECHANICAL AND ELECTRONIC
    Brisson, H.
    Bouhemad, B.
    Lu, Q.
    Rouby, J-J
    INTENSIVE CARE MEDICINE, 2011, 37 : S79 - S79
  • [7] Variations in endotracheal cuff pressure in intubated critically ill patients: prevalence and risk factors
    Nseir, Saad
    Brisson, Helene
    Marquette, Charles-Hugo
    Chaud, Pascal
    Di Pompeo, Christophe
    Diarra, Maimouna
    Durocher, Alain
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (03) : 229 - 234
  • [8] MEASUREMENTS OF CUFF PRESSURE OF DIFFERENT LOW-PRESSURE CUFFED ENDOTRACHEAL-TUBES UNDER MECHANICAL VENTILATION
    HOVENER, B
    ANAESTHESIST, 1977, 26 (12): : 651 - 658
  • [9] Tolerance of endotracheal tubes in patients on mechanical ventilation
    Nydahl, P.
    Hermes, C.
    Dubb, R.
    Kaltwasser, A.
    Schuchhardt, D.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (01) : 68 - 76
  • [10] The changes of cuff pressure from endotracheal intubation for long-term mechanical ventilation
    Jung, BH
    Kim, MA
    Koh, Y
    CHEST, 2004, 126 (04) : 900S - 900S