Using Capillary Whole Blood to Quantitatively Measure Ferritin: A Validation Trial of a Point-of-Care System

被引:2
|
作者
Fiddler, Joanna L. [1 ,2 ]
McBurney, Michael I. [3 ,4 ]
Haas, Jere D. [1 ]
机构
[1] Cornell Univ, Div Nutr Sci, Ithaca, NY 14853 USA
[2] Clemson Univ, Dept Food Nutr & Packaging Sci, Clemson, SC 29634 USA
[3] Univ Guelph, Dept Human Hlth & Nutr Sci, Guelph, ON N1G 2W1, Canada
[4] Tufts Univ, Friedman Sch Nutr Policy & Sci, Boston, MA 02111 USA
关键词
ferritin; diagnostic device; finger stick; blood; capillary; venous; nutritional deficiency; IRON-DEFICIENCY; DONORS; PREVALENCE;
D O I
10.3390/nu15061305
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Iron deficiency is a public health problem with devastating health, developmental and behavioral effects which often exacerbated due to affordability and access to screening and diagnosis. Using IronScan (TM) a portable, point-of-care diagnostic system capable of quantitatively measuring ferritin in blood, we validated IronScan (TM) ferritin measurements using whole blood and serum with a lab-based, regulator-approved analytical device for measuring ferritin in venous serum. Capillary (finger stick) and venous whole blood samples were obtained from 44 male and female volunteers. Venous serum (vSer) ferritin concentrations were measured on Immulite 2000 Xpi (gold standard). Capillary whole blood (cWB), venous whole blood (vWB), and vSer ferritin levels were measured by IronScan (TM). cWB ferritin concentrations from IronScan (TM) were significantly correlated (R-2 = 0.86) with vSer measured with the FDA-approved Immulite system. The results from the multiple regression analysis indicate that 10% of the variability was due to the method of blood collection (venous vs. capillary) and 6% was due to the form of blood analysis (whole blood vs. serum). The sensitivity of diagnosing iron deficiency using the WHO cutoff of <30 ng/mL is 90%, with a specificity of 96%. In conclusion, IronScan (TM) is a rapid viable option for measuring ferritin as a point-of-care system.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Reliability of Point-of-Care Capillary Blood Glucose Measurements in the Critical Value Range
    Schifman, Ron B.
    Nguyen, Tan T.
    Page, Susan T.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2014, 138 (07) : 962 - 966
  • [32] RELIABILITY OF PREHOSPITAL POINT-OF-CARE CAPILLARY BLOOD GLUCOSE MEASUREMENT IN STROKE CODE
    Savia, A.
    Camerlingo, S.
    Sanchez De Paz, M. P.
    Esterkies, G.
    Clementel, C.
    Iriarte, C.
    Huerta, S.
    INTERNATIONAL JOURNAL OF STROKE, 2020, 15 (1_SUPPL) : 216 - 216
  • [33] Fluorescent capillary fill device: a quantitative, whole blood assay system suited to point of care use
    Daniels, PB
    Vessey, JP
    Fletcher, JE
    O'Neill, PM
    Stafford, CG
    Cope, A
    Bacarese-Hamilton, T
    Cookson, AD
    SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 28 - 39
  • [34] Use of Citrated Whole Blood for Point-of-Care Viscoelastic Coagulation Testing in Dogs
    York, Whitney
    Smith, M. Ryan
    Liu, Chin-Chi
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [35] Use of Stabilized Whole Blood for Glucose Proficiency Testing at Point-of-Care Sites
    Liang, Shu-Ling
    Schmith, Eric
    Hunsley, Bradford
    Sornson, Hal
    Clarke, William
    POINT OF CARE, 2008, 7 (02): : 64 - 68
  • [36] A SERS Composite Hydrogel Device for Point-of-Care Analysis of Neurotransmitter in Whole Blood
    Wu, Lei
    Liu, Xuefeng
    Zong, Shenfei
    Wang, Zhuyuan
    Cui, Yiping
    BIOSENSORS-BASEL, 2023, 13 (06):
  • [37] Toward development of a point-of-care assay of enoxaparin anticoagulant activity in whole blood
    Inchiosa, Mario A., Jr.
    Pothula, Suryanarayana
    Kubal, Keshar
    Sanchala, Vajubhai T.
    Navarro, Iris
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2011, 32 (01) : 47 - 53
  • [38] Sampling for point-of-care analysis of lithium in whole blood with chip based CE
    Vrouwe, E
    Luttge, R
    van den Berg, A
    Micro Total Analysis Systems 2004, Vol 1, 2005, (296): : 503 - 505
  • [39] Whole Blood Point-of-Care Testing for Incomplete Reversal With Idarucizumab in Supratherapeutic Dabigatran
    Takeshita, Shusuke
    Tanaka, Kenichi A.
    Sawa, Teiji
    Sanda, Masashi
    Mizobe, Toshiki
    Ogawa, Satoru
    ANESTHESIA AND ANALGESIA, 2020, 130 (02): : 535 - 541
  • [40] Toward development of a point-of-care assay of enoxaparin anticoagulant activity in whole blood
    Mario A. Inchiosa
    Suryanarayana Pothula
    Keshar Kubal
    Vajubhai T. Sanchala
    Iris Navarro
    Journal of Thrombosis and Thrombolysis, 2011, 32 : 47 - 53