A SERS Composite Hydrogel Device for Point-of-Care Analysis of Neurotransmitter in Whole Blood

被引:6
|
作者
Wu, Lei [1 ]
Liu, Xuefeng [1 ]
Zong, Shenfei [1 ]
Wang, Zhuyuan [1 ]
Cui, Yiping [1 ]
机构
[1] Southeast Univ, Adv Photon Ctr, Sch Elect Sci & Engn, Nanjing 210096, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 06期
基金
中国国家自然科学基金;
关键词
surface enhanced Raman spectroscopy (SERS); hydrogel; neurotransmitter; point-of-care test;
D O I
10.3390/bios13060611
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Point-of-care analysis of neurotransmitters in body fluids plays a significant role in healthcare improvement. Conventional approaches are limited by time-consuming procedures and usually require laboratory instruments for sample preparation. Herein, we developed a surface enhanced Raman spectroscopy (SERS) composite hydrogel device for the rapid analysis of neurotransmitters in whole blood samples. The PEGDA/SA composite hydrogel enabled fast separation of small molecules from the complex blood matrix, while the plasmonic SERS substrate allowed for the sensitive detection of target molecules. 3D printing was employed to integrate the hydrogel membrane and the SERS substrate into a systematic device. The sensor achieved highly sensitive detection of dopamine in whole blood samples with a limit of detection down to 1 nM. The whole detection process from sample preparation to SERS readout can be finished within 5 min. Due to the simple operation and rapid response, the device shows great potential in point-of-care diagnosis and the monitoring of neurological and cardiovascular diseases and disorders.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A novel point-of-care device accurately measures thyrotropin in whole blood, capillary blood and serum
    Kahaly, George J.
    Lotz, Johannes
    Walder, Sara
    Hammad, Cara
    Kraemer, Rebecca
    Frommer, Lara
    Koenig, Jochem
    Wolf, Jan
    Gottwald-Hostalek, Ulrike
    Urgatz, Bogumila
    Lackner, Karl J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (10) : 1607 - 1616
  • [2] Sampling for point-of-care analysis of lithium in whole blood with chip based CE
    Vrouwe, E
    Luttge, R
    van den Berg, A
    Micro Total Analysis Systems 2004, Vol 1, 2005, (296): : 503 - 505
  • [3] Hemolysis Rates in Whole Blood Samples for Blood Gas/Electrolyte Analysis by Point-of-Care Testing
    Wilson, Amanda
    Sweeney, Maranna
    Lynch, P. L. Mark
    O'Kane, Maurice J.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2018, 3 (01): : 144 - 145
  • [4] Novel Point-of-Care Whole Blood Thrombin Generation Assay
    Stephens, Daniel
    Butenas, Saulius
    Mann, Kenneth G.
    Ferrara, Micheal J.
    Joseph, Immermann M.
    Spears, Grant M.
    Bailey, Kent R.
    Jenkins, Donald
    Kozar, Rosemary
    Ashrani, Aneel A.
    Park, Myung S.
    TRANSFUSION, 2019, 59 : 114A - 114A
  • [5] Evaluation of a whole blood point-of-care coagulation analyzer in dogs
    Conroy, Elizabeth M.
    Lyons, Bridget M.
    Koenig, Amie
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024, 34 (05) : 446 - 454
  • [6] Clinical evaluation of the first medical whole blood, point-of-care testing device for detection of myocardial infarction
    Apple, FS
    Anderson, FP
    Collinson, P
    Jesse, RL
    Kontos, MC
    Levitt, MA
    Miller, EA
    Murakami, MM
    CLINICAL CHEMISTRY, 2000, 46 (10) : 1604 - 1609
  • [7] Fibrinogen measurement by a novel point-of-care device with whole blood: comparison of values against Clauss method
    Shoko Okahara
    Tetsuya Handoh
    Mitsuru Wakita
    Takamasa Yamamoto
    Shigeki Misawa
    Takashi Miida
    Hiroyuki Sumikura
    Journal of Anesthesia, 2021, 35 : 757 - 760
  • [8] A Gel-Based Separation-Free Point-of-Care Device for Whole Blood Glucose Detection
    Dai, Jing
    Zhang, Han
    Huang, Can
    Chen, Zheyuan
    Han, Arum
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 16122 - 16129
  • [9] Fibrinogen measurement by a novel point-of-care device with whole blood: comparison of values against Clauss method
    Okahara, Shoko
    Handoh, Tetsuya
    Wakita, Mitsuru
    Yamamoto, Takamasa
    Misawa, Shigeki
    Miida, Takashi
    Sumikura, Hiroyuki
    JOURNAL OF ANESTHESIA, 2021, 35 (05) : 757 - 760
  • [10] A point-of-care microfluidic channel-based device for rapid and direct detection of fibrinogen in whole blood
    Ban, Qinan
    Zhang, Yulong
    Li, Yuxuan
    Cao, Daye
    Ye, Weifeng
    Zhan, Linsheng
    Wang, Daming
    Wang, Xiaohui
    LAB ON A CHIP, 2022, 22 (14) : 2714 - 2725