A SERS Composite Hydrogel Device for Point-of-Care Analysis of Neurotransmitter in Whole Blood

被引:6
|
作者
Wu, Lei [1 ]
Liu, Xuefeng [1 ]
Zong, Shenfei [1 ]
Wang, Zhuyuan [1 ]
Cui, Yiping [1 ]
机构
[1] Southeast Univ, Adv Photon Ctr, Sch Elect Sci & Engn, Nanjing 210096, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 06期
基金
中国国家自然科学基金;
关键词
surface enhanced Raman spectroscopy (SERS); hydrogel; neurotransmitter; point-of-care test;
D O I
10.3390/bios13060611
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Point-of-care analysis of neurotransmitters in body fluids plays a significant role in healthcare improvement. Conventional approaches are limited by time-consuming procedures and usually require laboratory instruments for sample preparation. Herein, we developed a surface enhanced Raman spectroscopy (SERS) composite hydrogel device for the rapid analysis of neurotransmitters in whole blood samples. The PEGDA/SA composite hydrogel enabled fast separation of small molecules from the complex blood matrix, while the plasmonic SERS substrate allowed for the sensitive detection of target molecules. 3D printing was employed to integrate the hydrogel membrane and the SERS substrate into a systematic device. The sensor achieved highly sensitive detection of dopamine in whole blood samples with a limit of detection down to 1 nM. The whole detection process from sample preparation to SERS readout can be finished within 5 min. Due to the simple operation and rapid response, the device shows great potential in point-of-care diagnosis and the monitoring of neurological and cardiovascular diseases and disorders.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Smart Point-of-care Systems for Molecular Diagnostics based on Nanotechnology; Whole Blood Glucose Analysis
    Devadhasan, Jasmine P.
    Kim, Sanghyo
    INTERNATIONAL CONFERENCE ON NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY 2015, 2015, 9523
  • [22] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687
  • [23] Optoelectronic microfluidic device for point-of-care blood plasma viscosity measurement
    Bakhtiaridoost, Somayyeh
    Musuroi, Cristian
    Volmer, Marius
    Florescu, Monica
    LAB ON A CHIP, 2024, 24 (13) : 3305 - 3314
  • [24] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [25] Point-of-care device: a word of caution
    Bhagwat, A. G.
    Taneja, S.
    Singal, N.
    Narang, S.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (01) : 138 - 139
  • [26] Combined Impedance and Dielectrophoresis Portable Device for Point-of-Care Analysis
    del Moral Zamora, B.
    Colomer-Farrarons, J.
    Mir-Llorente, M.
    Homs-Corbera, A.
    Miribel-Catala, P.
    Samitier-Marti, J.
    BIOELECTRONICS, BIOMEDICAL, AND BIOINSPIRED SYSTEMS V AND NANOTECHNOLOGY V, 2011, 8068
  • [27] Quantitative hematocrit measurement of whole blood in a point-of-care lateral flow device using a smartphone flow tracking app
    Frantz, Eric
    Li, Hua
    Steckl, Andrew J.
    BIOSENSORS & BIOELECTRONICS, 2020, 163 (163):
  • [28] Use of Citrated Whole Blood for Point-of-Care Viscoelastic Coagulation Testing in Dogs
    York, Whitney
    Smith, M. Ryan
    Liu, Chin-Chi
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [29] Rapid analysis of whole blood by paper spray mass spectrometry for point-of-care therapeutic drug monitoring
    Espy, Ryan D.
    Manicke, Nicholas E.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2012, 137 (10) : 2344 - 2349
  • [30] Use of Stabilized Whole Blood for Glucose Proficiency Testing at Point-of-Care Sites
    Liang, Shu-Ling
    Schmith, Eric
    Hunsley, Bradford
    Sornson, Hal
    Clarke, William
    POINT OF CARE, 2008, 7 (02): : 64 - 68