Blue-Light Filtering Monofocal Intraocular Lenses: A Study on Optical Function and Tolerance to Misalignment

被引:3
|
作者
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Univ Hosp Heidelberg, David J Apple Ctr Vis Res, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
SPHERICAL-ABERRATION; CATARACT-SURGERY; VISUAL-ACUITY; IMAGE QUALITY; MODEL; DECENTRATION; FOCUS; PERFORMANCE; IMPACT; DEPTH;
D O I
10.3928/1081597X-20240112-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the optical performance and toler- ance to misalignment of blue -light filtering monofocal intra- ocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5 -mm pu- pils. In addition, each IOL's tolerance to misalignment was ex- amined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested us- ing a 3 -mm aperture and an SA -neutral corneal model, indi- cated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic ab- erration, the CT Lucia 621 PY maintained its minimally bet- ter performance. When assessed with a 4.5 -mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration -free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal sim- ulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, display- ing a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79 -e88.]
引用
收藏
页码:e79 / e88
页数:10
相关论文
共 50 条
  • [21] Evaluation of visual performance and eye movements in patients with blue light-filtering intraocular lenses versus ultraviolet light-filtering intraocular lenses
    Liu, Yan
    Ren, Xiaotong
    Wan, Yu
    Yang, Luling
    Zhang, Rong
    Li, Xuemin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [22] Comparison of visual performance with blue light-filtering and ultraviolet light-filtering intraocular lenses
    Neumaier-Ammerer, Beatrix
    Felke, Stefan
    Hagen, Stefan
    Haas, Paulina
    Zeiler, Florian
    Mauler, Harald
    Binder, Susanne
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2073 - 2079
  • [23] Contrast sensitivity and higher order aberrations with aspheric and blue-light filter intraocular lenses
    Wohlfart, C.
    Tschuschnig, K.
    Fellner, P.
    Weiss, K.
    Vidic, B.
    El-Shabrawi, Y.
    Ardjomand, N.
    SPEKTRUM DER AUGENHEILKUNDE, 2006, 20 (06) : 260 - 263
  • [24] A comparison of clinical outcomes and optical performance between monofocal and new monofocal with enhanced intermediate function intraocular lenses: a case-control study
    Jungah Huh
    Youngsub Eom
    Seul Ki Yang
    Young Choi
    Hyo Myung Kim
    Jong Suk Song
    BMC Ophthalmology, 21
  • [25] Optical performance of monofocal versus multifocal intraocular lenses REPLY
    Ortiz, Dolores
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1818 - 1818
  • [26] Optical performance of monofocal and multifocal intraocular lenses in the human eye
    Ortiz, Dolores
    Alio, Jorge L.
    Bernabeu, Gonzalo
    Pongo, Vanessa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 755 - 762
  • [27] Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses
    D'Oria, Francesco
    Nowrouzi, Ali
    del Barrio, Jorge Alio L.
    Versaci, Francesco
    Alio, Jorge L.
    PHOTONICS, 2021, 8 (12)
  • [28] Exploring associations between blue light filtering intraocular lenses and dementia risk
    Lee, Cecilia S.
    Li, Pei-Ru
    Blazes, Marian
    Lee, Jiahn-Shing
    See, Lai-Chu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (08) : 1214 - 1215
  • [29] Clinical results of the blue-light filtering AcrySof Natural foldable acrylic intraocular lens
    Marshall, J
    Cionni, RJ
    Davison, J
    Ernest, P
    Lehmann, R
    Maxwell, A
    Solomon, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12): : 2319 - 2323
  • [30] Blue-light filtering intraocular lens in patients with diabetes:: Contrast sensitivity and chromatic discrimination
    Rodríguez-Galietero, A
    Montés-Micó, R
    Muñoz, G
    Albarrán-Diego, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11): : 2088 - 2092