Blue-Light Filtering Monofocal Intraocular Lenses: A Study on Optical Function and Tolerance to Misalignment

被引:3
|
作者
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Univ Hosp Heidelberg, David J Apple Ctr Vis Res, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
SPHERICAL-ABERRATION; CATARACT-SURGERY; VISUAL-ACUITY; IMAGE QUALITY; MODEL; DECENTRATION; FOCUS; PERFORMANCE; IMPACT; DEPTH;
D O I
10.3928/1081597X-20240112-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the optical performance and toler- ance to misalignment of blue -light filtering monofocal intra- ocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5 -mm pu- pils. In addition, each IOL's tolerance to misalignment was ex- amined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested us- ing a 3 -mm aperture and an SA -neutral corneal model, indi- cated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic ab- erration, the CT Lucia 621 PY maintained its minimally bet- ter performance. When assessed with a 4.5 -mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration -free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal sim- ulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, display- ing a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79 -e88.]
引用
收藏
页码:e79 / e88
页数:10
相关论文
共 50 条
  • [31] A comparison of clinical outcomes and optical performance between monofocal and new monofocal with enhanced intermediate function intraocular lenses: a case-control study
    Huh, Jungah
    Eom, Youngsub
    Yang, Seul Ki
    Choi, Young
    Kim, Hyo Myung
    Song, Jong Suk
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [32] The Effect of Blue-light Filtering Intraocular Lenses on the Development and Progression of Macular Atrophy in Eyes With Neovascular Age-related Macular Degeneration
    Achiron, Asaf
    Trivizki, Omer
    Knyazer, Boris
    Elbaz, Uri
    Hecht, Idan
    Jeon, Sohee
    Kanclerz, Piotr
    Tuuminen, Raimo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 266 : 135 - 143
  • [33] Comparative visual performance of ultraviolet light-filtering and violet light-filtering monofocal intraocular lenses of the same material and basic design
    Tanabe, Hirotaka
    Tabuchi, Hitoshi
    Shojo, Tomohiro
    Yamauchi, Tomofusa
    Takase, Kosuke
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [34] Influence of blue-light-filtering intraocular lenses on daytime levels of melatonin (BluMel-Study)
    Kubista, Katharina E.
    Brunner, Simon
    Glittenberg, Carl G.
    Hochwarter, Anelia
    Binder, Susanne
    SPEKTRUM DER AUGENHEILKUNDE, 2013, 27 (04) : 176 - 180
  • [35] Blue light-filtering intraocular lenses and post-operative mood: a pilot clinical study
    Stephanie Leruez
    Cedric Annweiler
    Benedicte Gohier
    Olivier Beauchet
    Jean-Marc Ebran
    Philippe Gohier
    Dan Milea
    International Ophthalmology, 2015, 35 : 249 - 256
  • [36] Blue light-filtering intraocular lenses and post-operative mood: a pilot clinical study
    Leruez, Stephanie
    Annweiler, Cedric
    Gohier, Benedicte
    Beauchet, Olivier
    Ebran, Jean-Marc
    Gohier, Philippe
    Milea, Dan
    INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (02) : 249 - 256
  • [37] Blue-light filtering spectacle lenses for visual performance, sleep, and macular health in adults (Review)
    Singh, Sumeer
    Keller, Peter R.
    Busija, Ljoudmila
    McMillan, Patrick
    Makrai, Eve
    Lawrenson, John G.
    Hull, Christopher C.
    Downie, Laura E.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2023, (08):
  • [38] Blue light-filtering and violet light-filtering hydrophobic acrylic foldable intraocular lenses: Intraindividual comparison
    Nakano, Shinichiro
    Miyata, Akira
    Kizawa, Junya
    Kurosaka, Daijiro
    Miyata, Kazunori
    Oshika, Tetsuro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1393 - 1403
  • [39] Effects of blue-light-filtering intraocular lenses on contrast sensitivity in patients with glaucoma
    Kitnarong, Naris
    Udomwech, Lunla
    Chongthurakit, Nisarate
    Phongsuphan, Theerajate
    Petchyim, Sakaorat
    MEDICINE, 2023, 102 (52) : E36821
  • [40] Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses
    Nagai, Hiroyuki
    Hirano, Yoshio
    Yasukawa, Tsutomu
    Morita, Hiroshi
    Nozaki, Miho
    Wolf-Schnurrbusch, Ute
    Wolf, Sebastian
    Ogura, Yuichiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (09): : 1855 - 1859