Blue-Light Filtering Monofocal Intraocular Lenses: A Study on Optical Function and Tolerance to Misalignment

被引:3
|
作者
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Univ Hosp Heidelberg, David J Apple Ctr Vis Res, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
SPHERICAL-ABERRATION; CATARACT-SURGERY; VISUAL-ACUITY; IMAGE QUALITY; MODEL; DECENTRATION; FOCUS; PERFORMANCE; IMPACT; DEPTH;
D O I
10.3928/1081597X-20240112-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the optical performance and toler- ance to misalignment of blue -light filtering monofocal intra- ocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5 -mm pu- pils. In addition, each IOL's tolerance to misalignment was ex- amined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested us- ing a 3 -mm aperture and an SA -neutral corneal model, indi- cated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic ab- erration, the CT Lucia 621 PY maintained its minimally bet- ter performance. When assessed with a 4.5 -mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration -free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal sim- ulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, display- ing a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79 -e88.]
引用
收藏
页码:e79 / e88
页数:10
相关论文
共 50 条
  • [41] Blue light-filtering intraocular lenses: Review of potential benefits and side effects
    Cuthbertson, Fiona M.
    Peirson, Stuart N.
    Wulff, Katharina
    Foster, Russell G.
    Downes, Susan M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1281 - 1297
  • [42] Influence of Blue-Light-Filtering Intraocular Lenses on Color Perception and Contrast Acuity
    Wirtitsch, Matthias G.
    Schmidinger, Gerald
    Prskavec, Martin
    Rubey, Martin
    Skorpik, Florian
    Heinze, Georg
    Findl, Oliver
    Karnik, Nadja
    OPHTHALMOLOGY, 2009, 116 (01) : 39 - 45
  • [43] Refractive tolerance in the use of monofocal intraocular lenses enhanced with new aspheric design
    Toyama, Naoki
    Kuwabara, Naoto
    Ogata, Miyuki
    Mori, Yosai
    Minami, Keiichiro
    Miyata, Kazunori
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [44] Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses
    Altemir-Gomez, Irene
    Millan, Maria S.
    Vega, Fidel
    Bartol-Puyal, Francisco
    Gimenez-Calvo, Galadriel
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    Garcia-Martin, Elena
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 299 - 306
  • [45] Effect of illumination on visual function in patients with monofocal and multifocal intraocular lenses
    Elgohary, MAH
    Beckingsale, AB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U306 - U306
  • [46] Psychophysical Measurements of Luminance Contrast Sensitivity and Color Discrimination with Transparent and Blue-Light Filter Intraocular Lenses
    da Costa M.F.
    Júnior A.P.
    Lottenberg C.L.
    Castro L.C.
    Ventura D.F.
    Ophthalmology and Therapy, 2017, 6 (2) : 301 - 312
  • [47] Transmission spectrums and retinal blue-light irradiance values of untinted and yellow-tinted intraocular lenses
    Tanito, Masaki
    Okuno, Tsutomu
    Ishiba, Yoshihisa
    Ohira, Akihiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 299 - 307
  • [48] A comparison of blue-light transmissions through blue-control lenses
    Carlson, Anthony S.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2019, 78 (01):
  • [49] Blue Light Filtration in Intraocular Lenses: Effects on Visual Function and Systemic Health
    Kohnen, Thomas
    Hammond, Billy R.
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1575 - 1586
  • [50] Laboratory Evaluation of Optical Performance of Aspheric Monofocal Intraocular Lenses With Various Anti-misalignment Designs Under the Influence of Decentration and Tilt
    Ren, Zhichao
    Liu, Xiaomin
    Zhang, Ying
    Li, Wenfeng
    Huang, Yusen
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (07) : 446 - +