Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

被引:3
|
作者
D'Oria, Francesco [1 ]
Nowrouzi, Ali [2 ]
del Barrio, Jorge Alio L. [3 ]
Versaci, Francesco [4 ]
Alio, Jorge L. [3 ]
机构
[1] Univ Bari, Dept Basic Med Sci Neurosci & Sense Organs, Sect Ophthalmol, I-70124 Bari, Italy
[2] Hosp Quironsalud, Ophthalmol Dept, Marbella 29670, Spain
[3] Miguel Hernandez Univ, Dept Ophthalmol, Alicante 03015, Spain
[4] Costruz Strumenti Oftalmici CSO, R&D Dept, I-50018 Florence, Italy
关键词
retinal image quality; multifocal refractive IOL; monofocal IOL; pyramidal aberrometer; PERFORMANCE; OUTCOMES; LIFE;
D O I
10.3390/photonics8120559
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations' RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 +/- 0.11 and 0.28 +/- 0.07) followed by LENTIS Mplus 15 (group C, 0.35 +/- 0.1 and 0.21 +/- 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 +/- 0.08 and 0.18 +/- 0.06) and Precizon Presbyopic (group D, 0.27 +/- 0.07 and 0.17 +/- 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Retinal straylight in patients with monofocal and multifocal intraocular lenses
    Cervino, Alejandro
    Hosking, Sarah L.
    Montes-Mico, Robert
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 441 - 446
  • [2] Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses
    Altemir-Gomez, Irene
    Millan, Maria S.
    Vega, Fidel
    Bartol-Puyal, Francisco
    Gimenez-Calvo, Galadriel
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    Garcia-Martin, Elena
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 299 - 306
  • [3] MULTIFOCAL VERSUS MONOFOCAL INTRAOCULAR LENSES VISUAL AND REFRACTIVE COMPARISONS
    ELMAGHRABY, A
    MARZOUKY, A
    GAZAYERLI, E
    VANDERKARR, M
    DELUCA, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02): : 147 - 152
  • [4] Optical performance of monofocal versus multifocal intraocular lenses
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1817 - 1818
  • [5] Clinical Results of Diffractive, Refractive, Hybrid Multifocal, and Monofocal Intraocular Lenses
    Dyrda, Agnieszka
    Martinez-Palmer, Ana
    Martin-Moral, Daniel
    Rey, Amanda
    Morilla, Antonio
    Castilla-Marti, Miguel
    Arones-Santivanez, Janny
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [6] Optical performance of monofocal versus multifocal intraocular lenses REPLY
    Ortiz, Dolores
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1818 - 1818
  • [7] Optical performance of monofocal and multifocal intraocular lenses in the human eye
    Ortiz, Dolores
    Alio, Jorge L.
    Bernabeu, Gonzalo
    Pongo, Vanessa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 755 - 762
  • [8] In Vitro Evaluation of the Optical Quality of Segmental Refractive Multifocal Intraocular Lenses
    Yildirim, Timur Mert
    Auffarth, Gerd Uwe
    Tandogan, Tamer
    Liebing, Stephanie
    Labuz, Grzegorz
    Choi, Chul Young
    Khoramnia, Ramin
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (08) : 983 - 989
  • [9] Binocular function after bilateral implantation of monofocal and refractive multifocal intraocular lenses
    Arens, B
    Freudenthaler, N
    Quentin, CD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03): : 399 - 404
  • [10] Influence of astigmatism on multifocal and monofocal intraocular lenses
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 477 - 482