Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

被引:3
|
作者
D'Oria, Francesco [1 ]
Nowrouzi, Ali [2 ]
del Barrio, Jorge Alio L. [3 ]
Versaci, Francesco [4 ]
Alio, Jorge L. [3 ]
机构
[1] Univ Bari, Dept Basic Med Sci Neurosci & Sense Organs, Sect Ophthalmol, I-70124 Bari, Italy
[2] Hosp Quironsalud, Ophthalmol Dept, Marbella 29670, Spain
[3] Miguel Hernandez Univ, Dept Ophthalmol, Alicante 03015, Spain
[4] Costruz Strumenti Oftalmici CSO, R&D Dept, I-50018 Florence, Italy
关键词
retinal image quality; multifocal refractive IOL; monofocal IOL; pyramidal aberrometer; PERFORMANCE; OUTCOMES; LIFE;
D O I
10.3390/photonics8120559
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations' RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 +/- 0.11 and 0.28 +/- 0.07) followed by LENTIS Mplus 15 (group C, 0.35 +/- 0.1 and 0.21 +/- 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 +/- 0.08 and 0.18 +/- 0.06) and Precizon Presbyopic (group D, 0.27 +/- 0.07 and 0.17 +/- 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparative visual performance with monofocal and multifocal intraocular lenses
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1979 - 1985
  • [22] Halos in refractive multifocal intraocular lenses
    Pieh, S
    Zöhrer, R
    Backner, B
    Hanselmayer, G
    Ruhswurm, I
    Scholz, U
    Weghaupt, H
    Skorpik, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S298 - S298
  • [23] Comparative Analysis of Optical Quality of Monofocal, Enhanced Monofocal, Multifocal, and Extended Depth of Focus Intraocular Lenses: A Mobile Model Eye Study
    Kim, Eun Chul
    Cho, Soo Yeon
    Kang, Ji Eon
    Nam, Gahee
    Yoon, Young Chae
    Whang, Woong-Joo
    Na, Kyung-Sun
    Kim, Hyun-Seung
    Hwang, Ho Sik
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (07):
  • [24] Outcomes of Rhegmatogenous Retinal Detachment Repair in Pseudophakic Eyes With Multifocal vs Monofocal Intraocular Lenses
    Shahlaee, Abtin
    Israilevich, Rachel N.
    Mahmoudzadeh, Raziyeh
    Salabati, Mirataollah
    Wakabayashi, Taku
    Yonekawa, Yoshihiro
    Klufas, Michael A.
    JOURNAL OF VITREORETINAL DISEASES, 2024, 8 (06) : 675 - 680
  • [25] Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted
    Guirao, A
    Redondo, M
    Geraghty, E
    Piers, P
    Norrby, S
    Artal, P
    ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (09) : 1143 - 1151
  • [26] Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison
    Ye, Pan-Pan
    Li, Xia
    Yao, Ke
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (03) : 300 - 306
  • [27] Cost-effectiveness of multifocal intraocular lenses compared to monofocal intraocular lenses in cataract surgery
    Hu, Jenny Qin
    Sarkar, Reith
    Murphy, James
    Afshari, Natalie A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [28] Multifocal versus monofocal intraocular lenses after cataract extraction
    Calladine, Daniel
    Evans, Jennifer R.
    Shah, Sweata
    Leyland, Martin
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (09):
  • [29] Comparing the Effect of Monofocal and Multifocal Intraocular Lenses on Macular Surgery
    Altun, A.
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [30] Multifocal versus monofocal intraocular lenses after cataract extraction
    Leyland, M.
    Pringle, E.