Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

被引:3
|
作者
D'Oria, Francesco [1 ]
Nowrouzi, Ali [2 ]
del Barrio, Jorge Alio L. [3 ]
Versaci, Francesco [4 ]
Alio, Jorge L. [3 ]
机构
[1] Univ Bari, Dept Basic Med Sci Neurosci & Sense Organs, Sect Ophthalmol, I-70124 Bari, Italy
[2] Hosp Quironsalud, Ophthalmol Dept, Marbella 29670, Spain
[3] Miguel Hernandez Univ, Dept Ophthalmol, Alicante 03015, Spain
[4] Costruz Strumenti Oftalmici CSO, R&D Dept, I-50018 Florence, Italy
关键词
retinal image quality; multifocal refractive IOL; monofocal IOL; pyramidal aberrometer; PERFORMANCE; OUTCOMES; LIFE;
D O I
10.3390/photonics8120559
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations' RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 +/- 0.11 and 0.28 +/- 0.07) followed by LENTIS Mplus 15 (group C, 0.35 +/- 0.1 and 0.21 +/- 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 +/- 0.08 and 0.18 +/- 0.06) and Precizon Presbyopic (group D, 0.27 +/- 0.07 and 0.17 +/- 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison
    Pan-Pan Ye
    Xia Li
    Ke Yao
    International Journal of Ophthalmology, 2013, (03) : 300 - 306
  • [32] Refraction and defocus curves in eyes with monofocal and multifocal intraocular lenses
    Rodriguez-Vallejo, Manuel
    Burguera, Noemi
    Rocha-de-Lossada, Carlos
    Aramberri, Jaime
    Fernandez, Joaquin
    JOURNAL OF OPTOMETRY, 2023, 16 (03) : 236 - 243
  • [33] Multifocal versus monofocal intraocular lenses after cataract extraction
    de Silva, Samantha R.
    Evans, Jennifer R.
    Kirthi, Varo
    Ziaei, Mohammed
    Leyland, Martin
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (12):
  • [34] Multifocal intraocular lenses and retinal diseases
    Grzybowski, Andrzej
    Kanclerz, Piotr
    Tuuminen, Raimo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (04) : 805 - 813
  • [35] Multifocal intraocular lenses and retinal diseases
    Andrzej Grzybowski
    Piotr Kanclerz
    Raimo Tuuminen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 805 - 813
  • [36] VISUAL AND REFRACTIVE RESULTS OF MULTIFOCAL INTRAOCULAR LENSES
    GIMBEL, HV
    SANDERS, DR
    RAANAN, MG
    OPHTHALMOLOGY, 1991, 98 (06) : 881 - 888
  • [37] Refractive technology to improve intermediate vision in monofocal intraocular lenses
    Alarcon, Aixa
    Canovas, Carmen
    Koopman, Bram
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [38] Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal Lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Amparo, Francisco
    Jimenez, Ramon
    Rodriguez-Prats, Jose L.
    Javaloy, Jaime
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) : 570 - 581
  • [39] Cost-Effectiveness Analysis of Multifocal Intraocular Lenses Compared to Monofocal Intraocular Lenses in Cataract Surgery
    Hu, Jenny Q.
    Sarkar, Reith
    Sella, Ruti
    Murphy, James D.
    Afshari, Natalie A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 305 - 312
  • [40] Cost effectiveness of foldable multifocal intraocular lenses compared to foldable monofocal intraocular lenses for cataract surgery
    Dolders, MGT
    Nijkamp, MD
    Nuijts, RMMA
    van den Borne, B
    Hendrikse, F
    Ament, A
    Groot, W
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (09) : 1163 - 1168