Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope

被引:0
|
作者
江晓芸 [1 ]
丁翼晨 [1 ]
王文耀 [2 ]
黄智宇 [1 ]
王志茹 [3 ,4 ]
Elie de Lestrange Anginieur [1 ]
俞玥 [1 ]
李军 [3 ]
濮鸣亮 [2 ]
任秋实 [1 ]
李长辉 [1 ]
机构
[1] Department of Biomedical Engineering, Peking University
[2] Department of Anatomy, School of Basic Medical Sciences, Peking University
[3] Laboratory Animal Center, Peking University
[4] School of Public Health, Jilin University
基金
美国国家科学基金会;
关键词
Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope;
D O I
暂无
中图分类号
R314 [医用仿生学];
学科分类号
0831 ; 0836 ;
摘要
Since significant ocular differences in both anatomical structure and optical properties exist between rodents and humans, clinical imaging devices for human use are not suitable for use on rodents. In this study, we develop a contact probe with a flexible surface that can closely fit the rodent cornea for fundus imaging with a confocal scanning laser ophthalmoscope. Both Zemax simulation and in vivo fundus imaging demonstrate that this contact probe can significantly improve both the imaging quality and the operational convenience.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 50 条
  • [1] Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope
    Jiang, Xiaoyun
    Ding, Yichen
    Wang, Wenyao
    Huang, Zhiyu
    Wang, Zhiru
    Anginieur, Elie de Lestrange
    Yu, Yue
    Li, Jun
    Pu, Mingliang
    Ren, Qiushi
    Li, Changhui
    [J]. CHINESE OPTICS LETTERS, 2016, 14 (03)
  • [2] CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE
    WOON, WH
    FITZKE, FW
    BIRD, AC
    MARSHALL, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) : 470 - 474
  • [3] CONFOCAL FUNDUS IMAGING WITH A SCANNING LASER OPHTHALMOSCOPE IN EYES WITH CATARACT
    BECKMAN, C
    BONDTAYLOR, L
    LINDBLOM, B
    SJOSTRAND, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) : 900 - 904
  • [4] Topography of fundus autofluorescence using a confocal scanning laser ophthalmoscope
    Bellmann, C
    Holt, FG
    Schapp, O
    Volcker, HE
    Otto, TP
    [J]. OPHTHALMOLOGE, 1997, 94 (06): : 385 - 391
  • [5] Fundus autofluorescence mapping using a confocal scanning laser ophthalmoscope
    Bindewald, A
    Schmitz-Valckenberg, S
    Holz, FG
    [J]. MACULA: DIAGNOSIS, TREATMENT AND FUTURE TRENDS, 2004, : 239 - 245
  • [6] Imaging a child's fundus without dilation using a handheld confocal scanning laser ophthalmoscope
    Kelly, JP
    Weiss, AH
    Zhou, Q
    Schmode, S
    Dreher, AW
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (03) : 391 - 396
  • [7] DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE
    MANIVANNAN, A
    SHARP, PF
    PHILLIPS, RP
    FORRESTER, JV
    [J]. PHYSIOLOGICAL MEASUREMENT, 1993, 14 (01) : 43 - 56
  • [8] IMAGING RETINAL DENSITOMETRY WITH A CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    VANNORREN, D
    VANDEKRAATS, J
    [J]. VISION RESEARCH, 1989, 29 (12) : 1825 - 1830
  • [9] CONFOCAL SCANNING LASER OPHTHALMOSCOPE
    WEBB, RH
    HUGHES, GW
    DELORI, FC
    [J]. APPLIED OPTICS, 1987, 26 (08): : 1492 - 1499
  • [10] Altered fundus appearance resulting from autofluorescence imaging with the confocal scanning laser ophthalmoscope (cSLO) in cats
    Occelli, Laurence M.
    Petersen-Jones, Simon M.
    [J]. VETERINARY OPHTHALMOLOGY, 2014, 17 (05) : 385 - 388