DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE

被引:39
|
作者
MANIVANNAN, A
SHARP, PF
PHILLIPS, RP
FORRESTER, JV
机构
[1] UNIV ABERDEEN,DEPT OPHTHALMOL,ABERDEEN AB9 2ZD,SCOTLAND
[2] ROYAL PERTH HOSP,PERTH,WA 6001,AUSTRALIA
关键词
D O I
10.1088/0967-3334/14/1/006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While many systemic diseases have ophthalmic manifestations with visible pathological features affecting the fundus, diabetic eye disease is of particular interest. There are many advantages in using digital image analysis to quantify the extent of retinal pathology in diabetes particularly to monitor its progression. However, the usual method of imaging involves photographing the retina using a fundus camera. Not only does this require that the photographs be digitized prior to analysis, but the resulting illumination across the image is non-uniform and this creates problems in digital image analysis. This paper describes the construction of a scanning laser ophthalmoscope interfaced to a computer, which has a number of significant advantages for digital retinal imaging. Firstly, it has better uniformity of illumination than the fundus camera and operates at much lower light levels. Secondly, it permits imaging at various wavelengths with no consequent degradation in image quality; in particular, the value of imaging at infrared wavelengths to give greater tissue penetration is demonstrated. Finally, by introducing the capability for confocal imaging, tomographic images can be taken, improving the perceptibility of features situated deep in the retina. Typical images are shown to demonstrate the potential of this instrument.
引用
收藏
页码:43 / 56
页数:14
相关论文
共 50 条
  • [1] CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE
    WOON, WH
    FITZKE, FW
    BIRD, AC
    MARSHALL, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) : 470 - 474
  • [2] True colour imaging of the fundus using a scanning laser ophthalmoscope
    Vieira, P
    Manivannan, A
    Sharp, PF
    Forrester, JV
    [J]. PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) : 1 - 10
  • [3] CONFOCAL FUNDUS IMAGING WITH A SCANNING LASER OPHTHALMOSCOPE IN EYES WITH CATARACT
    BECKMAN, C
    BONDTAYLOR, L
    LINDBLOM, B
    SJOSTRAND, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) : 900 - 904
  • [4] FUNDUS TRACKING WITH THE SCANNING LASER OPHTHALMOSCOPE
    WORNSON, DP
    HUGHES, GW
    WEBB, RH
    [J]. APPLIED OPTICS, 1987, 26 (08): : 1500 - 1504
  • [5] FUNDUS LASER COAGULATION USING A VIDEO SYSTEM OF SCANNING LASER OPHTHALMOSCOPE
    PEYMAN, GA
    KHOOBEHI, B
    SHAMSNIA, S
    NAVARRO, GC
    [J]. LASERS IN SURGERY AND MEDICINE, 1993, 13 (06) : 680 - 684
  • [6] Topography of fundus autofluorescence using a confocal scanning laser ophthalmoscope
    Bellmann, C
    Holt, FG
    Schapp, O
    Volcker, HE
    Otto, TP
    [J]. OPHTHALMOLOGE, 1997, 94 (06): : 385 - 391
  • [7] Fundus autofluorescence mapping using a confocal scanning laser ophthalmoscope
    Bindewald, A
    Schmitz-Valckenberg, S
    Holz, FG
    [J]. MACULA: DIAGNOSIS, TREATMENT AND FUTURE TRENDS, 2004, : 239 - 245
  • [8] DISTRIBUTION OF FUNDUS AUTOFLUORESCENCE WITH A SCANNING LASER OPHTHALMOSCOPE
    VONRUCKMANN, A
    FITZKE, FW
    BIRD, AC
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (05) : 407 - 412
  • [9] Imaging a child's fundus without dilation using a handheld confocal scanning laser ophthalmoscope
    Kelly, JP
    Weiss, AH
    Zhou, Q
    Schmode, S
    Dreher, AW
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (03) : 391 - 396
  • [10] KINETIC FUNDUS PERIMETRY WITH THE SCANNING LASER OPHTHALMOSCOPE
    ROHRSCHNEIDER, K
    BECKER, M
    FENDRICH, T
    VOLCKER, HE