Imaging a child's fundus without dilation using a handheld confocal scanning laser ophthalmoscope

被引:15
|
作者
Kelly, JP
Weiss, AH
Zhou, Q
Schmode, S
Dreher, AW
机构
[1] Childrens Hosp & Med Ctr, Dept Ophthalmol, Seattle, WA 98105 USA
[2] LDT Inc, San Diego, CA USA
关键词
D O I
10.1001/archopht.121.3.391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Images of the fundus were acquired in children without pupil dilation using a prototype handheld confocal scanning laser ophthalmoscope (SLO). A 780-nm laser beam imaged a 20degrees X 20degrees area of the fundus while a 645-nm beam scanned a fixation target. Scorable images of the optic nerve, macula, and vessels were obtained in 67 (72%) of 93 eyes from pediatric patients with nystagmus, amblyopia, media opacities, or optic nerve or macular abnormalities. Images were obtained in all eyes of pediatric and adult controls. Unsuccessful imaging was associated with media opacities, high refractive error, and poor cooperation. Disadvantages of the SLO were the inability to detect optic nerve pallor or consistently image the periphery. Advantages of the SLO were seen in children with nystagmus, photophobia, eccentric fixation, cone dystrophy, and mild papilledema.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [1] CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE
    WOON, WH
    FITZKE, FW
    BIRD, AC
    MARSHALL, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) : 470 - 474
  • [2] CONFOCAL FUNDUS IMAGING WITH A SCANNING LASER OPHTHALMOSCOPE IN EYES WITH CATARACT
    BECKMAN, C
    BONDTAYLOR, L
    LINDBLOM, B
    SJOSTRAND, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) : 900 - 904
  • [3] Fundus imaging in children without dilation by a hand-held scanning laser ophthalmoscope (SLO).
    Kelly, JP
    Weiss, AH
    Zhou, Q
    Schmode, S
    Dreher, AW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S383 - S383
  • [4] Topography of fundus autofluorescence using a confocal scanning laser ophthalmoscope
    Bellmann, C
    Holt, FG
    Schapp, O
    Volcker, HE
    Otto, TP
    [J]. OPHTHALMOLOGE, 1997, 94 (06): : 385 - 391
  • [5] Fundus autofluorescence mapping using a confocal scanning laser ophthalmoscope
    Bindewald, A
    Schmitz-Valckenberg, S
    Holz, FG
    [J]. MACULA: DIAGNOSIS, TREATMENT AND FUTURE TRENDS, 2004, : 239 - 245
  • [6] DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE
    MANIVANNAN, A
    SHARP, PF
    PHILLIPS, RP
    FORRESTER, JV
    [J]. PHYSIOLOGICAL MEASUREMENT, 1993, 14 (01) : 43 - 56
  • [7] Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope
    Jiang, Xiaoyun
    Ding, Yichen
    Wang, Wenyao
    Huang, Zhiyu
    Wang, Zhiru
    Anginieur, Elie de Lestrange
    Yu, Yue
    Li, Jun
    Pu, Mingliang
    Ren, Qiushi
    Li, Changhui
    [J]. CHINESE OPTICS LETTERS, 2016, 14 (03)
  • [8] Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope
    江晓芸
    丁翼晨
    王文耀
    黄智宇
    王志茹
    Elie de Lestrange Anginieur
    俞玥
    李军
    濮鸣亮
    任秋实
    李长辉
    [J]. Chinese Optics Letters, 2016, 14 (03) : 80 - 83
  • [9] True colour imaging of the fundus using a scanning laser ophthalmoscope
    Vieira, P
    Manivannan, A
    Sharp, PF
    Forrester, JV
    [J]. PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) : 1 - 10
  • [10] Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope
    Lois, N
    Halfyard, AS
    Bunce, C
    Bird, AC
    Fitzke, FW