Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope

被引:0
|
作者
江晓芸 [1 ]
丁翼晨 [1 ]
王文耀 [2 ]
黄智宇 [1 ]
王志茹 [3 ,4 ]
Elie de Lestrange Anginieur [1 ]
俞玥 [1 ]
李军 [3 ]
濮鸣亮 [2 ]
任秋实 [1 ]
李长辉 [1 ]
机构
[1] Department of Biomedical Engineering, Peking University
[2] Department of Anatomy, School of Basic Medical Sciences, Peking University
[3] Laboratory Animal Center, Peking University
[4] School of Public Health, Jilin University
基金
美国国家科学基金会;
关键词
Developing a contact probe for rodent fundus imaging in a confocal scanning laser ophthalmoscope;
D O I
暂无
中图分类号
R314 [医用仿生学];
学科分类号
0831 ; 0836 ;
摘要
Since significant ocular differences in both anatomical structure and optical properties exist between rodents and humans, clinical imaging devices for human use are not suitable for use on rodents. In this study, we develop a contact probe with a flexible surface that can closely fit the rodent cornea for fundus imaging with a confocal scanning laser ophthalmoscope. Both Zemax simulation and in vivo fundus imaging demonstrate that this contact probe can significantly improve both the imaging quality and the operational convenience.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 50 条
  • [31] CONFOCAL SCANNING LASER OPHTHALMOSCOPE WITH A SLIT APERTURE
    KOBAYASHI, K
    NAKANO, H
    MATSUI, H
    AKIYAMA, K
    ASAKURA, T
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (04) : 287 - 292
  • [32] Optimization of confocal scanning laser ophthalmoscope design
    LaRocca, Francesco
    Dhalla, Al-Hafeez
    Kelly, Michael P.
    Farsiu, Sina
    Izatt, Joseph A.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (07)
  • [33] Spectrally encoded confocal scanning laser ophthalmoscope
    Tao, Yuankai K.
    Izatt, Joseph A.
    [J]. OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [34] COMPUTERIZED STEREOIMAGE BY CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    FUNATSU, H
    MISHIMA, HK
    KIUCHI, Y
    KANEDA, K
    YAMASHITA, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1506 - 1506
  • [35] Normal values for fundus perimetry with the scanning laser ophthalmoscope
    Rohrschneider, K
    Becker, M
    Schumacher, N
    Fendrich, T
    Völcker, HE
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) : 52 - 58
  • [36] Visualization of retinal vessel printings using the confocal scanning laser ophthalmoscope and the fundus camera in vitreoretinal pathologies
    Filippelli, Mariaelena
    dell'Omo, Roberto
    Cifariello, Francesco
    Giorgio, Dario
    Calo, Rocco
    Di Iorio, Roberto
    Cardone, Michele
    Di Salvatore, Angela
    Costagliola, Ciro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [37] Retro-mode imaging and fundus autofluorescence with scanning laser ophthalmoscope of retinal dystrophies
    Battaglia Parodi Maurizio
    Iacono Pierluigi
    Kontadakis Stelios
    Vergallo Stefano
    Cascavilla Marialucia
    Zucchiatti Ilaria
    Bandello Francesco
    [J]. BMC Ophthalmology, 12
  • [38] Retro-mode imaging and fundus autofluorescence with scanning laser ophthalmoscope of retinal dystrophies
    Maurizio, Battaglia Parodi
    Pierluigi, Iacono
    Stelios, Kontadakis
    Stefano, Vergallo
    Marialucia, Cascavilla
    Ilaria, Zucchiatti
    Francesco, Bandello
    [J]. BMC OPHTHALMOLOGY, 2012, 12
  • [39] Fundus autofluorescence Imaging compared with different confocal scanning laser ophthalmoscopes
    Bellmann, C
    Rubin, GS
    Kabanarou, SA
    Bird, AC
    Fitzke, FW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U603 - U603
  • [40] IMAGING THE SPATIAL-DISTRIBUTION OF FUNDUS AUTOFLUORESCENCE WITH A LASER-SCANNING OPHTHALMOSCOPE (CLSO)
    FITZKE, FW
    VONRUCKMANN, A
    BIRD, AC
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S238 - S238