In vivo dosimetry for proton therapy: A Monte Carlo study of the Gadolinium spectral response throughout the course of treatment

被引:0
|
作者
Bras, Mariana [1 ,2 ,3 ]
Freitas, Hugo [1 ,4 ]
Goncalves, Patricia [2 ,3 ]
Seco, Joao [1 ,4 ]
机构
[1] German Canc Res Ctr, E041,Neuenheimer Feld 223, D-69120 Heidelberg, Germany
[2] Lab Intrumentacao & Fis Expt Particulas, Lisbon, Portugal
[3] Univ Lisbon, Inst Super Tecn, Dept Phys, Lisbon, Portugal
[4] Heidelberg Univ, Dept Phys & Astron, D-69115 Heidelberg, Germany
基金
瑞典研究理事会;
关键词
contrast agent; dosimetry; gadolinium; in-vivo; proton therapy; real-time; tracking; treatment plan; NEUTRON-CAPTURE THERAPY; K-SHELL IONIZATION; RANGE UNCERTAINTIES; NANOPARTICLES; DELIVERY; TUMORS; SETUP;
D O I
10.1002/mp.17625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIn proton radiotherapy, the steep dose deposition profile near the end of the proton's track, the Bragg peak, ensures a more conformed deposition of dose to the tumor region when compared with conventional radiotherapy while reducing the probability of normal tissue complications. However, uncertainties, as in the proton range, patient geometry, and positioning pose challenges to the precise and secure delivery of the treatment plan (TP). In vivo range determination and dose distribution are pivotal for mitigation of uncertainties, opening the possibility to reduce uncertainty margins and for adaptation of the TP.PurposeThis study aims to explore the feasibility of utilizing gadolinium (Gd), a highly used contrast agent in MRI, as a surrogate for in vivo dosimetry during the course of scanning proton therapy, tracking the delivery of a TP and the impact of uncertainties intra- and inter-fraction in the course of treatment.MethodsMonte Carlo simulations (Geant4 11.1.1) were performed, where a Gd-filled volume was placed within a water phantom and underwent treatment with a scanning proton TP delivering 4 Gy. The secondary photons emitted upon proton-Gd interaction were recorded and assessed for various tumor displacements. The spectral response of Gd to each pencil beam irradiation is therefore used as a surrogate for dose measurements during treatment.ResultsResults show that the deposited dose at the target volume can be tracked for each TP scanning point by correlating it with the recorded Gd signal. The analyzed Gd spectral line corresponded to the characteristic X-ray k alpha$\text{k}_\alpha$ line at 43 keV. Displacements from the planned geometry could be distinguished by observing changes in the Gd signal induced by each pencil beam. Moreover, the total 43 keV signal recorded subsequently to the full TP delivery reflected deviations from the planned integral dose to the target.ConclusionsThe study suggests that the spectral response of a Gd-based contrast agent can be used for in vivo dosimetry, providing insights into the TP delivery. The Gd 43 keV spectral line was correlated with the dose at the tumor, its volume, and its position. Other variables that can impact the method, such as the kinetic energy of the incident protons and Gd concentration in the target were also discussed.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Monte Carlo simulation and polymer gel dosimetry of 60 MeV clinical proton beams for the treatment of ocular tumours
    Baker, C. R.
    Quine, T. E.
    Brunt, J. N. H.
    Kacperek, A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (03) : 402 - 405
  • [42] Proton energy and scattering angle radiographs to improve proton treatment planning: a Monte Carlo study
    Biegun, A. K.
    Takatsu, J.
    Nakaji, T.
    van Goethem, M. J.
    van der Graaf, E. R.
    Koffeman, E. N.
    Visser, J.
    Brandenburg, S.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [43] Monte Carlo Simulation Study of In-beam Intra-treatment PET Imaging for Adaptive Proton Therapy
    Lou, Kai
    Mirkovic, Dragan
    Sun, Xishan
    Zhu, Xiaorong Ronald
    Clark, John, Jr.
    Shao, Yiping
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] Comparative Photon and Proton Dosimetry for Patients with Mediastinal Lymphoma in the Era of Monte Carlo Treatment Planning and Variable RBE
    Tseng, Y. D.
    Maes, S. M.
    Kicska, G.
    Traneus, E.
    Wong, T. P.
    Stewart, R. D.
    Saini, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S86 - S87
  • [45] GRID-ENABLED TREATMENT PLANNING FOR PROTON THERAPY USING MONTE CARLO SIMULATIONS
    Vadapalli, Ravi
    Yepes, Pablo
    Newhauser, Wayne
    Lichti, Roger
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 16 - 21
  • [46] A fast - Monte Carlo toolkit on GPU for treatment plan dose recalculation in proton therapy
    Senzacqua, M.
    Schiavi, A.
    Patera, V
    Pioli, S.
    Battistoni, G.
    Ciocca, M.
    Mairani, A.
    Magro, G.
    Molinelli, S.
    28TH ANNUAL IUPAP CONFERENCE ON COMPUTATIONAL PHYSICS (CCP2016), 2017, 905
  • [47] Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning
    Moravek, Zdenek
    Rickhey, Mark
    Hartmann, Matthias
    Bogner, Ludwig
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4803 - 4819
  • [48] Configuration of a Treatment Planning System with Monte Carlo Simulations for a Compact Proton Therapy Unit
    Zheng, Y.
    Klein, E.
    Rosenthal, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [49] Beam Model Interface for Treatment Planning in Proton Therapy Using Macro Monte Carlo
    Fix, M. K.
    Frei, D.
    Volken, W.
    Born, E. J.
    Aebersold, D. M.
    Manser, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault
    Zheng, Yuanshui
    Newhauser, Wayne
    Klein, Eric
    Low, Daniel
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6943 - 6957