In vivo dosimetry for proton therapy: A Monte Carlo study of the Gadolinium spectral response throughout the course of treatment

被引:0
|
作者
Bras, Mariana [1 ,2 ,3 ]
Freitas, Hugo [1 ,4 ]
Goncalves, Patricia [2 ,3 ]
Seco, Joao [1 ,4 ]
机构
[1] German Canc Res Ctr, E041,Neuenheimer Feld 223, D-69120 Heidelberg, Germany
[2] Lab Intrumentacao & Fis Expt Particulas, Lisbon, Portugal
[3] Univ Lisbon, Inst Super Tecn, Dept Phys, Lisbon, Portugal
[4] Heidelberg Univ, Dept Phys & Astron, D-69115 Heidelberg, Germany
基金
瑞典研究理事会;
关键词
contrast agent; dosimetry; gadolinium; in-vivo; proton therapy; real-time; tracking; treatment plan; NEUTRON-CAPTURE THERAPY; K-SHELL IONIZATION; RANGE UNCERTAINTIES; NANOPARTICLES; DELIVERY; TUMORS; SETUP;
D O I
10.1002/mp.17625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIn proton radiotherapy, the steep dose deposition profile near the end of the proton's track, the Bragg peak, ensures a more conformed deposition of dose to the tumor region when compared with conventional radiotherapy while reducing the probability of normal tissue complications. However, uncertainties, as in the proton range, patient geometry, and positioning pose challenges to the precise and secure delivery of the treatment plan (TP). In vivo range determination and dose distribution are pivotal for mitigation of uncertainties, opening the possibility to reduce uncertainty margins and for adaptation of the TP.PurposeThis study aims to explore the feasibility of utilizing gadolinium (Gd), a highly used contrast agent in MRI, as a surrogate for in vivo dosimetry during the course of scanning proton therapy, tracking the delivery of a TP and the impact of uncertainties intra- and inter-fraction in the course of treatment.MethodsMonte Carlo simulations (Geant4 11.1.1) were performed, where a Gd-filled volume was placed within a water phantom and underwent treatment with a scanning proton TP delivering 4 Gy. The secondary photons emitted upon proton-Gd interaction were recorded and assessed for various tumor displacements. The spectral response of Gd to each pencil beam irradiation is therefore used as a surrogate for dose measurements during treatment.ResultsResults show that the deposited dose at the target volume can be tracked for each TP scanning point by correlating it with the recorded Gd signal. The analyzed Gd spectral line corresponded to the characteristic X-ray k alpha$\text{k}_\alpha$ line at 43 keV. Displacements from the planned geometry could be distinguished by observing changes in the Gd signal induced by each pencil beam. Moreover, the total 43 keV signal recorded subsequently to the full TP delivery reflected deviations from the planned integral dose to the target.ConclusionsThe study suggests that the spectral response of a Gd-based contrast agent can be used for in vivo dosimetry, providing insights into the TP delivery. The Gd 43 keV spectral line was correlated with the dose at the tumor, its volume, and its position. Other variables that can impact the method, such as the kinetic energy of the incident protons and Gd concentration in the target were also discussed.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study
    Gear, J. I.
    Charles-Edwards, E.
    Partridge, M.
    Flux, G. D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7273 - 7286
  • [32] Minibeam radiation therapy: A micro- and nano-dosimetry Monte Carlo study
    Dos Santos, M.
    Delorme, R.
    Salmon, R.
    Prezado, Y.
    MEDICAL PHYSICS, 2020, 47 (03) : 1379 - 1390
  • [33] In-Vivo Simulation of the Relative Biological Effectiveness in Proton Therapy Using a Monte Carlo Method
    Oesten, H.
    Loeck, S.
    Helmbrecht, S.
    Tillner, F.
    Wohlfahrt, P.
    Schuemann, J.
    Luehr, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3621 - 3621
  • [34] A Monte Carlo Study of the Relationship between the Time Structures of Prompt Gammas and the In-vivo Radiation Dose in Proton Therapy
    Shin, Wook-Geun
    Min, Chul Hee
    Shin, Jae-Ik
    Jeong, Jong Hwi
    Lee, Se Byeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 248 - 253
  • [35] A Monte Carlo study of the relationship between the time structures of prompt gammas and the in-vivo radiation dose in proton therapy
    Wook-Geun Shin
    Chul Hee Min
    Jae-Ik Shin
    Jong Hwi Jeong
    Se Byeong Lee
    Journal of the Korean Physical Society, 2015, 67 : 248 - 253
  • [36] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [37] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [38] Monte Carlo Study of Neutron Dose Equivalent for a Compact Proton Therapy Unit
    Zheng, Y.
    Klein, E.
    Chen, K.
    Liu, Y.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [39] Prompt Gamma Spectroscopy of Metallic Implants in Proton Therapy: A Monte Carlo Study
    Liu, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E833 - E833
  • [40] Study of the secondary neutral radiation in proton therapy: Toward an indirect in vivo dosimetry
    Carnicer, A.
    Letellier, V.
    Rucka, G.
    Angellier, G.
    Sauerwein, W.
    Herault, J.
    MEDICAL PHYSICS, 2012, 39 (12) : 7303 - 7316