A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams

被引:20
|
作者
Charlwood, Frances C.
Aitkenhead, Adam H. [1 ]
Mackay, Ranald I.
机构
[1] Univ Manchester, Fac Med & Human Sci, MAHSC, Manchester M13 9PL, Lancs, England
关键词
proton therapy; pencil beam scanning; collimation; Monte Carlo; LATERAL PENUMBRA; SPOT SIZE; SIMULATION; OPTIMIZATION; REDUCTION; APERTURE; SCATTER; PATIENT; SYSTEM; MODEL;
D O I
10.1118/1.4941957
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) system. Use of a range-shifter to degrade the beam and allow treatment of very shallow depths further blurs the lateral edge. The authors investigate the potential use of a collimator with a PBS system for delivery of 3D uniform dose-volumes to a water-tank phantom, identifying the key factors controlling the width of the lateral edge. Methods: The GEANT 4 application for tomographic emission (GATE) Monte Carlo (MC) environment was used, following validation against previously published data. Key parameters for PBS beams were investigated to assess their impact on the lateral edge of both monoenergetic beams and uniform dose-volumes. These parameters included nozzle-to-surface distance (NSD), vacuum window-to-surface distance (VSD), use of a range-shifter, and spot optimization parameters. Results: The lateral edge of an uncollimated PBS beam is particularly sensitive to VSD and NSD. While use of a range-shifter blurs the lateral edge, collimation allows the edge to be sharpened to between 2 and 4 mm depending on the depth of the target. Optimization of the spot weightings alone can provide a penumbral width close to that of a single spot, but also leads to poorer uniformity near the edge of the target volume. Conclusions: Collimation of PBS beams should be considered for superficial targets particularly for beams delivered through a range-shifter, since the resultant sharpening of the lateral edge will allow improved sparing of adjacent normal tissues. Further work is needed to develop collimators which are integrated into both nozzle designs and planning system optimization algorithms. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:1462 / 1472
页数:11
相关论文
共 50 条
  • [1] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [2] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [3] Development and Validation of a TOPAS Monte Carlo Model of a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Rana, S.
    Gutierrez, A.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Monte Carlo model of a gantry for proton pencil beam scanning
    Winterhalter, Carla
    Safai, Sairos
    Grassberger, Clemens
    Oxley, David
    Weber, Damien C.
    Lomax, Tony
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 837 - 837
  • [6] Log file based Monte Carlo calculations for proton pencil beam scanning therapy
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [7] The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation
    Wang, Z.
    Gao, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 296 - 296
  • [8] Dynamic Collimation System Controller for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Flynn, R.
    Wang, D.
    Hyer, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E97 - E97
  • [9] Secondary Neutron Dose From a Dynamic Collimation System During Intracranial Pencil Beam Scanning Proton Therapy: A Monte Carlo Investigation
    Smith, Blake R.
    Hyer, Daniel E.
    Hill, Patrick M.
    Culberson, Wesley S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 103 (01): : 241 - 250
  • [10] Criteria of spot asymmetry in proton radiotherapy pencil beam scanning - a Monte Carlo study
    Klodowska, M.
    Gajewski, J.
    Skowronska, K.
    Olko, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S57 - S58