Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning

被引:7
|
作者
Moravek, Zdenek [1 ]
Rickhey, Mark [1 ]
Hartmann, Matthias [2 ]
Bogner, Ludwig [1 ]
机构
[1] Univ Hosp Regensburg, Dept Radiat Oncol, Regensburg, Germany
[2] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 15期
关键词
DOSE CALCULATION; PHOTON BEAMS; OPTIMIZATION; RADIOTHERAPY; SENSITIVITY; ALGORITHM; IMRT;
D O I
10.1088/0031-9155/54/15/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Treatment plans for intensity-modulated proton therapy may be sensitive to some sources of uncertainty. One source is correlated with approximations of the algorithms applied in the treatment planning system and another one depends on how robust the optimization is with regard to intra-fractional tissue movements. The irradiated dose distribution may substantially deteriorate from the planning when systematic errors occur in the dose algorithm. This can influence proton ranges and lead to improper modeling of the Braggpeak degradation in heterogeneous structures or particle scatter or the nuclear interaction part. Additionally, systematic errors influence the optimization process, which leads to the convergence error. Uncertainties with regard to organ movements are related to the robustness of a chosen beam setup to tissue movements on irradiation. We present the inverse Monte Carlo treatment planning system IKO for protons (IKO-P), which tries to minimize the errors described above to a large extent. Additionally, robust planning is introduced by beam angle optimization according to an objective function penalizing paths representing strongly longitudinal and transversal tissue heterogeneities. The same score function is applied to optimize spot planning by the selection of a robust choice of spots. As spots can be positioned on different energy grids or on geometric grids with different space filling factors, a variety of grids were used to investigate the influence on the spot-weight distribution as a result of optimization. A tighter distribution of spot weights was assumed to result in a more robust plan with respect to movements. IKO-P is described in detail and demonstrated on a test case and a lung cancer case as well. Different options of spot planning and grid types are evaluated, yielding a superior plan quality with dose delivery to the spots from all beam directions over optimized beam directions. This option shows a tighter spot-weight distribution and should therefore be less sensitive to movements compared to optimized directions. But accepting a slight loss in plan quality, the latter choice could potentially improve robustness even further by accepting only spots from the most proper direction. The choice of a geometric grid instead of an energy grid for spot positioning has only a minor influence on the plan quality, at least for the investigated lung case.
引用
收藏
页码:4803 / 4819
页数:17
相关论文
共 50 条
  • [1] Monte Carlo-based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy
    Li, Y.
    Tian, Z.
    Song, T.
    Wu, Z.
    Liu, Y.
    Jiang, S. B.
    Jia, X.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 475 - 478
  • [2] Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy
    Li, Y.
    Tian, Z.
    Song, T.
    Wu, Z.
    Liu, Y.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3616 - 3616
  • [3] Monte Carlo in the optimization of intensity modulated proton therapy
    Soukup, M.
    Alber, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2471 - 2471
  • [4] Monte Carlo Based Treatment Plan Optimization for Intensity Modulated Proton Therapy
    Kueng, R.
    Loebner, H. A.
    Mueller, S.
    Frei, D.
    Volken, W.
    Aebersold, D. M.
    Stampanoni, M. F. M.
    Fix, M. K.
    Manser, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E816 - E816
  • [5] Analytical models for probabilistic inverse treatment planning in intensity-modulated proton therapy
    Wahl, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S187 - S187
  • [6] Analytical models for probabilistic inverse treatment planning in intensity-modulated proton therapy
    Wahl, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S205 - S205
  • [7] Intensity modulated proton therapy planning by means of inverse kernel optimization
    Bogner, L
    Bauer, E
    Hartmann, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [8] Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy
    Yepes, Pablo
    Adair, Antony
    Grosshans, David
    Mirkovic, Dragan
    Poenisch, Falk
    Titt, Uwe
    Wang, Qianxia
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04):
  • [9] Intensity-modulated proton treatment planning with inverse kernel optimisation
    Moravek, Z.
    Bogner, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 29 - 29
  • [10] Monte Carlo validation of EYEPLAN proton therapy treatment planning
    Cirrone, G. A. P.
    Cuttone, G.
    Di Rosa, F.
    Russo, G.
    Salamone, V.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 273 - 276