Dosimetric response of Gafchromic™ EBT-XD film to therapeutic protons

被引:10
|
作者
Guan, Fada [1 ,2 ]
Wang, Xiaochun [1 ]
Yang, Ming [1 ]
Draeger, Emily [2 ]
Han, Dae [2 ]
Iga, Kiminori [1 ,3 ]
Guo, Fanqing [2 ]
Perles, Luis [1 ]
Li, Yuting [1 ]
Sahoo, Narayan [1 ]
Mohan, Radhe [1 ]
Chen, Zhe [2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[2] Yale Univ, Sch Med, Dept Therapeut Radiol, 333 Cedar St, New Haven, CT 06510 USA
[3] Hitachi Amer Ltd, Particle Therapy Div, Santa Clara, CA USA
来源
PRECISION RADIATION ONCOLOGY | 2023年 / 7卷 / 01期
关键词
EBT-XD film; FLASH dose rate; linear energy transfer; proton therapy; DEPENDENCE; MODEL;
D O I
10.1002/pro6.1187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EBT-XD model of Gafchromic (TM) films has a broader optimal dynamic dose range, up to 40 Gy, compared with its predecessor models. This characteristic has made EBT-XD films suitable for high-dose applications, such as stereotactic body radiotherapy and stereotactic radiosurgery, as well as ultra-high dose rate FLASH radiotherapy. The purpose of the current study was to characterize the dependence of EBT-XD film response on linear energy transfer (LET) and dose rate of therapeutic protons from a synchrotron. A clinical spot-scanning proton beam was used to study LET dependence at three dose-averaged LET values of 1.0 keV/mu m, 3.6 keV/mu m, and 7.6 keV/mu m. A research proton beamline was used to study dose rate dependence at 150 Gy/s in the FLASH mode and 0.3 Gy/s in the non-FLASH mode. Film response data from dose-averaged LET values of 0.9 keV/mu m and 9.0 keV/mu m of the proton FLASH beam were also compared. Film response data from a clinical 6-MV photon beam were used as a reference. Both the gray value method and optical density (OD) method were used in film calibration. Calibration results using a specific OD calculation method and a generic OD calculation method were compared. The four-parameter NIH Rodbard function and three-parameter rational function were compared in fitting the calibration curves. Experimental results showed that the response of EBT-XD film is proton LET dependent, but independent of dose rate. Goodness-of-fit analysis showed that using the NIH Rodbard function is superior for both protons and photons. Using the "specific OD + NIH Rodbard function" method for EBT-XD film calibration is recommended. The results of dose-rate independence of EBT-XD film to protons are shown in Figure G1. The FLASH dose rate is 150 Gy/s and the non-FLASH dose rate is 0.3 Gy/s. The linear energy transfer dependence of EBT-XD film to proton beams is shown in Figure G2. Film calibration curves from three different dose-averaged linear energy transfer values (1.0 keV/mu m, 3.6 keV/mu m, and 7.6 keV/mu m) using clinical 87.2 MeV protons are compared in Figure G2(A). Film calibration curves from two dose-averaged linear energy transfer values (0.9 keV/mu m and 9.0 keV/mu m) using FLASH 87.2 MeV protons are compared in Figure G2(B). image
引用
收藏
页码:15 / 26
页数:12
相关论文
共 50 条
  • [21] Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film
    Marchant Van der Walt
    Linda Marsh
    John Baines
    Stephen Gibson
    Ariadne Shoobridge
    Glenn de Vine
    Physical and Engineering Sciences in Medicine, 2022, 45 : 901 - 914
  • [22] Evaluation of the Response of EBT3, EBT-XD, MD-V3, and HD-V2 GafChromic Films in Proton FLASH Fields
    Darafsheh, A.
    Hao, Y.
    Owen, D.
    Zwart, T.
    Wagner, M.
    Zhao, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E193 - E193
  • [23] Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film
    Van der Walt, Marchant
    Marsh, Linda
    Baines, John
    Gibson, Stephen
    Shoobridge, Ariadne
    de Vine, Glenn
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (3) : 901 - 914
  • [24] Proton beam dosimetry at ultra-high dose rates (FLASH): Evaluation of GAFchromic™ (EBT3, EBT-XD) and OrthoChromic (OC-1) film performances
    Villoing, Daphnee
    Koumeir, Charbel
    Bongrand, Arthur
    Guertin, Arnaud
    Haddad, Ferid
    Metivier, Vincent
    Poirier, Freddy
    Potiron, Vincent
    Servagent, Noel
    Supiot, Stephane
    Delpon, Gregory
    Chiavassa, Sophie
    MEDICAL PHYSICS, 2022, 49 (04) : 2732 - 2745
  • [25] Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films
    Darafsheh, Arash
    Hao, Yao
    Maraghechi, Borna
    Cammin, Jochen
    Reynoso, Francisco J.
    Khan, Rao
    MEDICAL PHYSICS, 2020, 47 (09) : 4543 - 4552
  • [26] Response characterization of EBT-XD radiochromic films in megavoltage photon and electron beams
    Leon-Marroquin, E. Yazmin
    Mulrow, Daniel
    Darafsheh, Arash
    Khan, Rao
    MEDICAL PHYSICS, 2019, 46 (09) : 4246 - 4256
  • [27] The Effect of Scanning Orientation On New EBT-XD Film Using Vidar and Epson Scanners
    Chiu-Tsao, S.
    Chan, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3597 - 3597
  • [28] Is EBT-XD film suitable for linac and Gamma Knife radiosurgery dosimetry verification and audit?
    Nisbet, A.
    Dimitriadis, A.
    Palmer, A. L.
    Clark, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S723 - S723
  • [29] Investigating the method of selection of background pixel values for the calibration of EBT-XD film dosimetry
    Raj, Sathiya
    Shree, Nithya
    Kadirampatti, Ganesh
    PRECISION RADIATION ONCOLOGY, 2024, 8 (03): : 132 - 137
  • [30] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337