Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film

被引:4
|
作者
Van der Walt, Marchant [1 ]
Marsh, Linda [1 ]
Baines, John [1 ]
Gibson, Stephen [1 ]
Shoobridge, Ariadne [1 ]
de Vine, Glenn [1 ]
机构
[1] Townsville Hosp & Hlth Serv, Dept Med Phys, Townsville, Qld 4814, Australia
关键词
Radiochromic film dosimetry; Radiotherapy; Triple channel corrections; LED; RADIOCHROMIC FILM; DOCUMENT SCANNER; CALIBRATION;
D O I
10.1007/s13246-022-01161-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigate the properties of a light emitting diode (LED) flatbed scanner for use with EBT3 and EBT-XD film types in a clinical radiochromic film (RCF) dosimetry program with modern treatment techniques. The flatbed scanner was characterised in terms of lateral and longitudinal response, X-Y scaling integrity, scanning reproducibility, scanner warm up dependence and film orientation dependence. The preferred lateral response artefact (LRA) corrections are investigated for the LED light source. Supporting evidence is provided regarding the dose independent nature of the corrections while also providing results suggesting a potential film type independence. Results from 2D gamma analysis of four patient treatments were compared between the new 12000XL and existing 10000XL model. Lastly, a dose uncertainty analysis was performed for the film-scanner system combination. It may be concluded that the lateral response variation requires correction while the longitudinal response variation is insignificant. The linear scaling in the lateral and longitudinal directions are within 0.5% and the scanner reproducibility is stable. Scanner warm up dependence no longer exists, and effort should be made to maintain all film orientation in a study set within 15 degrees. The LRA corrections are as reported substantially dose independent and there is evidence to support film type independence. Comparative gamma analysis of patient specific dose maps between the EPSON 10000XL (xenon fluorescent lamp) and 12000XL (LED) scanners showed that results are indistinguishable for both film types across the two scanner models when the necessary corrections are applied. Dose uncertainty is in agreement with the literature and can be kept below 3% with necessary corrections applied.
引用
收藏
页码:901 / 914
页数:14
相关论文
共 50 条
  • [1] Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film
    Marchant Van der Walt
    Linda Marsh
    John Baines
    Stephen Gibson
    Ariadne Shoobridge
    Glenn de Vine
    Physical and Engineering Sciences in Medicine, 2022, 45 : 901 - 914
  • [2] Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
    Smyth, Lloyd
    Alves, Andrew
    Collins, Katherine
    Beveridge, Sabeena
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1095 - 1106
  • [3] Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
    Khachonkham, Suphalak
    Dreindl, Ralf
    Heilemann, Gerd
    Lechner, Wolfgang
    Fuchs, Hermann
    Palmans, Hugo
    Georg, Dietmar
    Kuess, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [4] Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification
    Palmer, Antony L.
    Dimitriadis, Alexis
    Nisbet, Andrew
    Clark, Catharine H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22): : 8741 - 8752
  • [5] Characterisation of EPSONV700 flatbed scanner for EBT3 Gafchromic film dosimetry
    Nelson, V.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S737 - S738
  • [6] Temperature dependent dose readout of Gafchromic EBT3 and EBT-XD film and clinical relevance in SRT
    Buchauer, K.
    Plasswilm, L.
    Schiefer, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S807 - S808
  • [7] Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry
    Matney, Jason E.
    Parker, Brent C.
    Neck, Daniel W.
    Henkelmann, Greg
    Rosen, Isaac I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 198 - 208
  • [8] Characteristic of EBT-XD versus EBT3 radiochromic films for dosimetry in photon and proton beams
    Kuess, P.
    Khachonkham, S.
    Dreindl, R.
    Heilemann, G.
    Lechner, W.
    Fuchs, H.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S457 - S458
  • [9] Monte Carlo Calculated Stopping-Power of EBT3 and EBT-XD Film for Pristine Proton Beams
    Shi, C.
    Chen, C.
    Mah, D.
    Chan, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [10] Growth kinetics of the EBT3 and EBT-XD films response in radiotherapy beams
    Momin, Shadab
    Khan, Rao
    Darafsheh, Arash
    OPTICS AND IONIZING RADIATION, 2020, 2020, 11224