Optimal screw orientation for fixation of coronal shear fractures: a biomechanical comparison

被引:0
|
作者
Lappen, Sebastian [1 ]
Siebenlist, Sebastian [1 ]
Leschinger, Tim [2 ,3 ]
Kadantsev, Pavel [1 ]
Geyer, Stephanie [1 ,4 ]
Wegmann, Kilian [2 ,3 ,5 ]
Mueller, Lars-Peter
Hackl, Michael [2 ,3 ]
机构
[1] Tech Univ Munich, Dept Sports Orthopead, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Univ Cologne, Fac Med, Ctr Orthoped & Trauma Surg, Cologne, Germany
[3] Univ Cologne, Univ Hosp, Ctr Orthoped & Trauma Surg, Cologne, Germany
[4] St Vinzenz Klin, Dept Orthoped, Pfronten, Germany
[5] OCM Orthopad Chirurg Munchen Clin, Munich, Germany
关键词
Capitellum; distal humerus; elbow; fracture fixation; humeral fracture; osteosynthesis; INTERNAL-FIXATION; OPEN REDUCTION; CAPITELLUM;
D O I
10.1016/j.jse.2024.05.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum. Methods: In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into 3 groups: fixation was either performed with 3 x 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 x 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 x 3.0 mm HCCSs in PA orientation and 1 x 3.0 mm HCCS in lateral orientation (LAT) group. Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens. Results: There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 +/- 0.5 mm vs. 0.8 +/- 0.6 mm; P = .987) or PA and LAT groups (0.8 +/- 0.6 mm vs. 0.8 +/- 0.3 mm; P = .966). LAT group showed the highest load-to- failure (548 +/- 250 N) without reaching statistically significant difference to AP group (388 +/- 173 N; P = .101). There was also no significant difference between AP and PA groups (388 +/- 173 N vs. 422 +/- 114 N; P = .649). Conclusions: Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in 2 planes-both the coronal and the sagittal plane-by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [31] FIXATION METHODS IN LATARJET: BIOMECHANICAL COMPARISON OF SCREW TYPES AND PLATE FIXATION
    Arzu, Ufuk
    Ersin, Mehmet
    Chodza, Mehmet
    Sahin, Koray
    Kilicoglu, Onder
    Ersen, Ali
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [32] Coronal shear fractures of the femoral neck: a comparison with basicervical fractures
    Yamakawa, Yasuaki
    Yamamoto, Norio
    Tomita, Yosuke
    Noda, Tomoyuki
    Inoue, Tomoo
    Matsumoto, Toshiyuki
    Kawasaki, Keisuke
    Ozaki, Toshifumi
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (01) : 419 - 430
  • [33] Coronal shear fractures of the femoral neck: a comparison with basicervical fractures
    Yasuaki Yamakawa
    Norio Yamamoto
    Yosuke Tomita
    Tomoyuki Noda
    Tomoo Inoue
    Toshiyuki Matsumoto
    Keisuke Kawasaki
    Toshifumi Ozaki
    European Journal of Trauma and Emergency Surgery, 2023, 49 : 419 - 430
  • [34] Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine
    Little, Andrew S.
    Brasiliense, Leonardo B. C.
    Lazaro, Bruno C. R.
    Reyes, Phillip M.
    Dickman, Curtis A.
    Crawford, Neil R.
    NEUROSURGERY, 2010, 66 (03) : 178 - 182
  • [36] A Biomechanical Comparison of Screw and Plate Fixations for Scaphoid Fractures
    Goodwin, Jill
    Castaneda, Paulo
    Drace, Patricia
    Edwards, Scott
    JOURNAL OF WRIST SURGERY, 2018, 7 (01) : 77 - 80
  • [37] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [38] Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures
    Dargel, J.
    Gick, S.
    Mader, K.
    Koebke, J.
    Pennig, D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 156 - 160
  • [39] Intramedullary screw fixation of proximal fifth metatarsal fractures: A biomechanical study
    Shah, SN
    Knoblich, GO
    Lindsey, DP
    Kreshak, J
    Yerby, SA
    Chou, LB
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (07) : 581 - 584
  • [40] Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study
    Miles, Megan R.
    Green, Tyler
    Parks, Brent G.
    Thakkar, Madhuli Y.
    Segalman, Keith A.
    Means, Kenneth R., Jr.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (05): : 476.e1 - 476.e6