Enhancing Patient-specific Quality Assurance in Carbon-ion Radiation Therapy: Recalculating Delivered Dose Distribution Using Log Data

被引:0
|
作者
Yun, Yongdo [1 ]
Han, Min cheol [1 ]
Kim, Changhwan [1 ]
Hong, Chae-Seon [1 ]
Kim, Dong wook [1 ]
Lee, Ho [1 ]
Kim, Hojin [1 ]
Han, Soorim [1 ]
Souda, Hikaru [2 ]
Lee, Sung hyun [3 ]
Miyasaka, Yuya [2 ]
Iwai, Takeo [2 ]
Kim, Jin sung [1 ,4 ]
机构
[1] Yonsei Univ, Coll Med, Heavy Ion Therapy Res Inst, Dept Radiat Oncol,Yonsei Canc Ctr, Seoul 03722, South Korea
[2] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[3] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
IN VIVO | 2025年 / 39卷 / 02期
关键词
Carbon-ion radiation therapy; log data; patient-specific quality assurance; treatment planning system; biological dose distribution;
D O I
10.21873/invivo.13913
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Log data from radiation treatment machines can play a crucial role in quality assurance by enabling the recalculation of the delivered dose distribution and identification of deviations in treatment delivery. This article proposes a novel method for recalculating the delivered dose distribution in carbon-ion radiation therapy using log data. Materials and Methods: The proposed approach leverages existing functionality in commercial treatment planning systems, thus eliminating the need for specialized in-house software for dose calculation and evaluation. The performed tests entail data generation from actual log files using the Digital Imaging and Communications in Medicine standard, biological dose calculations, and gamma evaluations. Results: The log-based approach demonstrated notable advantages, including improved time efficiency and the ability to calculate three-dimensional biological doses. By recalculating the delivered dose distributions, our method improves quality assurance accuracy in carbon-ion radiation therapy. It complements conventional measurement-based patient- specific quality assurance methods, serving as a valuable addition to the arsenal of tools available for treatment evaluation. Conclusion: We believe that our method has the potential to enhance the efficacy of patient-specific quality assurance and contribute significantly to the advancement of carbon-ion radiation therapy, thereby reinforcing the ongoing evolution of particle therapy.
引用
收藏
页码:1086 / 1093
页数:8
相关论文
共 50 条
  • [1] Three-dimensional Patient-specific Quality Assurance Using Beam Delivery Log Data for Pencil Beam Scanning Carbon-ion Radiotherapy
    Takashina, Masaaki
    Yagi, Masashi
    Noguchi, Yuuki
    Nakaji, Taku
    Hamatani, Noriaki
    Tsubouchi, Toshiro
    Kanai, Tatsuaki
    IN VIVO, 2024, 38 (06): : 2935 - 2944
  • [2] Inverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
    Lee, Jeong-Woo
    Park, Jeong-Hoon
    Chung, Jin-Beom
    Park, Ji-Yeon
    Choe, Bo-Young
    Suh, Tae-Suk
    Lee, Doo-Hyun
    Hong, Semie
    Kang, Min-Young
    Choi, Kyoung-Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1649 - 1656
  • [3] Analysis of dose comparison techniques for patient-specific quality assurance in radiation therapy
    Yu, Liting
    Tang, Timothy L. S.
    Cassim, Naasiha
    Livingstone, Alexander
    Cassidy, Darren
    Kairn, Tanya
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 189 - 198
  • [4] Patient-specific quality assurance using machine log files analysis for stereotactic body radiation therapy (SBRT)
    Chow, Vivian U. Y.
    Kan, Monica W. K.
    Chan, Anthony T. C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 179 - 187
  • [5] Evaluation of digital linac log data for patient-specific VMAT quality assurance
    U'wais, F.
    Zin, H. M.
    Radzi, Y.
    Rizan, N. N.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1346 - S1346
  • [6] Patient-Specific Quality Assurance Using Trajectory Log File-Based Dose Reconstruction for SRS VMAT
    Park, H.
    Park, J.
    Artz, M.
    Huh, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E826 - E826
  • [7] External dosimetry audit for quality assurance of carbon-ion radiation therapy clinical trials
    Mizuno, Hideyuki
    Fukumura, Akifumi
    Kanematsu, Nobuyuki
    Yonai, Shunsuke
    Shirai, Toshiyuki
    Yusa, Ken
    Yanou, Toshihiro
    Suga, Masaki
    Mizota, Manabu
    Minohara, Shinichi
    Kanai, Tatsuaki
    Kamada, Tadashi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 31 - 36
  • [8] Monte Carlo-Based Patient-Specific Quality Assurance System for Carbon-Ion Radiotherapy: System Development and Clinical Implementation
    Yun, Y.
    Lee, S. H.
    Han, M. C.
    Kim, J. S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7684 - 7684
  • [9] Optimization of Affine Transformation Parameters for Dose Matrix Warping in Patient-specific Quality Assurance of Radiation Therapy Dose Distributions Using an Evolutionary Algorithm
    Witten, M.
    Clancey, O.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S800 - S800
  • [10] Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Fujita, Yukio
    Shimizu, Eiji
    Matsunaga, Kenichi
    Sawada, Kinya
    Matsushita, Haruo
    Majima, Kazuhiro
    Jingu, Keiichi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1220 - 1225