Color Stability of Bulk-Fill Flowable Resin Composites After Artificial Aging

被引:0
|
作者
Floriani, Franciele [1 ]
Jurado, Carlos A. [2 ]
Madhu, Nikkita [1 ]
Lackey, Mark A. [2 ]
Azpiazu-Flores, Francisco X. [3 ]
Lopes, Guilherme Carpena [4 ]
机构
[1] Univ Iowa, Coll Dent, Dept Prosthodont, Iowa City, IA 52241 USA
[2] Univ Tennessee Hlth Sci Ctr, Coll Dent, Dept Gen Dent, Memphis, TN 38103 USA
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
关键词
resin composite; bulk-fill; color; flowable composite; shade; CLINICAL-PERFORMANCE; RESTORATIONS; VISCOSITY; PROFILE; TRIAL;
D O I
10.3390/dj12110350
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging. Methods: Disk-shaped specimens (& Oslash;10 x 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow, Venus Bulk-Fill Flow, and Estelite Bulk-Fill Flow). The specimens in each bulk-fill resin composite group were divided into two subgroups (n = 10 per subgroup) with two different shades, A1 (N = 30) and A3 (N = 30), and were polymerized with light curing (800 mW/cm(2)/Valo LED Unit, Ultradent) and polished. The color difference between bulk-fill resin composites was evaluated at baseline and after artificial aging using a spectrophotometer (CM-700d, Konica Minolta, Tokyo, Japan) under D65 illumination. Color coordinates were measured with CIEDE2000, and color differences (triangle E-00) and relative translucency parameter (RTP) values were calculated. Subsequently, the comparison of color changes (triangle E-00) before and after thermocycling was performed using the t-test for paired samples. Results: The bulk-fill flow resin composites evaluated in the present study were capable of mimicking important optical properties such as light transmission. All the resin composites provided acceptable color stability at baseline and after thermocycling when the color A1 was used. On the other hand, whenever the shade A3 was used, the Venus Bulk-Fill Flow demonstrated the best optical properties. There was no statistically significant difference when comparing baseline and after thermocycling in bulk-fill flowable resin composites (p > 0.05). After thermocycling, A1 bulk-fill flowable resin composites provided acceptable color stability, and all A3 bulk-fill flowable resin composites provided visible color change, except for the Venus Bulk-Fill Flow (triangle E-00 = 2.35). Conclusions: Estelite Bulk-Fill Flow displayed the best color stability (triangle E-00 = 2.22) between all the combinations evaluated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Frank Engelhardt
    Sebastian Hahnel
    Verena Preis
    Martin Rosentritt
    Clinical Oral Investigations, 2016, 20 : 2123 - 2130
  • [2] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Engelhardt, Frank
    Hahnel, Sebastian
    Preis, Verena
    Rosentritt, Martin
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (08) : 2123 - 2130
  • [3] Wear and Color Stability of Preheated Bulk-fill and Conventional Resin Composites RESPONSE
    Santi, Marina Rodrigues
    Lins, Rodrigo Barros Esteves
    Sahadi, Beatriz Ometto
    Soto-Montero, Jorge Rodrigo
    Martins, Luis Roberto Marcondes
    OPERATIVE DENTISTRY, 2022, 47 (05) : 593 - 594
  • [4] Comparison of occlusal wear between bulk-fill and conventional flowable resin composites
    Ujiie, Maho
    Tsujimoto, Akimasa
    Barkmeier, Wayne W.
    Jurado, Carlos A.
    Villalobos-Tinoco, Jose
    Takamizawa, Toshiki
    Latta, Mark A.
    Miyazaki, Masashi
    AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (02): : 74 - 78
  • [5] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [6] Fracture Load of Molars Restored with Bulk-fill, Flowable Bulk-fill, and Conventional Resin Composite After Simulated Chewing
    Guerra, L.
    Ramos, R. Q.
    Linhares, L. A.
    Bernardon, J. K.
    Favero, S. S.
    Cesar, P. F.
    Monteiro Junior, S.
    OPERATIVE DENTISTRY, 2023, 48 (03) : 294 - 303
  • [7] Polymerization Shrinkage and Depth of Cure of Bulk-Fill Resin Composites and Highly Filled Flowable Resin
    Jang, J-H
    Park, S-H
    Hwang, I-N
    OPERATIVE DENTISTRY, 2015, 40 (02) : 172 - 180
  • [8] Color stability of bulk-fill resin composites exposed to caffeinated beverage: An in vitro study
    Ozyurt, Esra
    Kurt, Aysegul
    AMERICAN JOURNAL OF DENTISTRY, 2022, 35 (01): : 3 - 8
  • [9] Curing characteristics of flowable and sculptable bulk-fill composites
    Miletic, Vesna
    Pongprueksa, Pong
    De Munck, Jan
    Brooks, Neil R.
    Van Meerbeek, Bart
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1201 - 1212
  • [10] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    Clinical Oral Investigations, 2017, 21 : 1201 - 1212