Curing characteristics of flowable and sculptable bulk-fill composites

被引:59
|
作者
Miletic, Vesna [1 ,2 ,3 ]
Pongprueksa, Pong [1 ,2 ]
De Munck, Jan [1 ,2 ]
Brooks, Neil R. [4 ]
Van Meerbeek, Bart [1 ,2 ]
机构
[1] KU Leuven Univ Leuven, BIOMAT, Dept Oral Hlth Sci, Kapucijnenvoer 7,Block A Box, B-7001 Leuven, Belgium
[2] Univ Hosp Leuven, Dent, Kapucijnenvoer 7,Block A Box, B-7001 Leuven, Belgium
[3] Univ Belgrade, Sch Dent Med, Belgrade, Serbia
[4] KU Leuven Univ Leuven, Dept Chem, Leuven, Belgium
关键词
Bulk-fill; Composites; Translucency; Depth of cure; Degree of conversion; Hardness; FIBER-REINFORCED COMPOSITE; POLYMER NETWORK MATRIX; RESIN-BASED COMPOSITES; MONOWAVE LED UNITS; SURFACE MICROHARDNESS; DENTAL RESINS; CONVERSION; DEPTH; CURE; SHRINKAGE;
D O I
10.1007/s00784-016-1894-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.
引用
收藏
页码:1201 / 1212
页数:12
相关论文
共 50 条
  • [1] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    [J]. Clinical Oral Investigations, 2017, 21 : 1201 - 1212
  • [2] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Dalia Kaisarly
    D. Meierhofer
    M. El Gezawi
    P. Rösch
    K.H. Kunzelmann
    [J]. Clinical Oral Investigations, 2021, 25 : 4927 - 4940
  • [3] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Kaisarly, Dalia
    Meierhofer, D.
    El Gezawi, M.
    Roesch, P.
    Kunzelmann, K. H.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (08) : 4927 - 4940
  • [4] Influence of resin matrix on the rheology, translucency, and curing potential of experimental flowable composites for bulk-fill applications
    Eiras Pereira, Leonardo Duarte
    Couto Neto, Mario Pereira
    Pereira, Roberto Guimaraes
    Schneider, Luis Felipe J.
    [J]. DENTAL MATERIALS, 2021, 37 (06) : 1046 - 1053
  • [5] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Frank Engelhardt
    Sebastian Hahnel
    Verena Preis
    Martin Rosentritt
    [J]. Clinical Oral Investigations, 2016, 20 : 2123 - 2130
  • [6] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Engelhardt, Frank
    Hahnel, Sebastian
    Preis, Verena
    Rosentritt, Martin
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (08) : 2123 - 2130
  • [7] Flowable and Regular Bulk-Fill Composites: A Comprehensive Report on Restorative Treatment
    Sebold, Maicon
    Esteves Lins, Rodrigo Barros
    Andre, Carolina Bosso
    Marcondes Martins, Luis Roberto
    Giannini, Marcelo
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (02) : 293 - 300
  • [8] Evaluation of Radiopacity of Bulk-fill Flowable Composites Using Digital Radiography
    Tarcin, B.
    Gumru, B.
    Peker, S.
    Ovecoglu, H. S.
    [J]. OPERATIVE DENTISTRY, 2016, 41 (04) : 424 - 431
  • [9] Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application
    Kaisarly, Dalia
    El Gezawi, Moataz
    Kessler, Andreas
    Roesch, Peter
    Kunzelmann, Karl-Heinz
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) : 1127 - 1139
  • [10] Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application
    Dalia Kaisarly
    Moataz El Gezawi
    Andreas Keßler
    Peter Rösch
    Karl-Heinz Kunzelmann
    [J]. Clinical Oral Investigations, 2021, 25 : 1127 - 1139