Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis

被引:32
|
作者
Engelhardt, Frank [1 ]
Hahnel, Sebastian [1 ]
Preis, Verena [1 ]
Rosentritt, Martin [1 ]
机构
[1] Univ Regensburg, Dept Prosthet Dent, Med Ctr, D-93042 Regensburg, Germany
关键词
Flowable; Bulk-fill; Composite; Mechanical properties; DSC; TGA; MECHANICAL-PROPERTIES; WEAR BEHAVIOR; DENTAL RESINS; PERFORMANCE; CONVERSION; MICROHARDNESS; STRENGTH; KINETICS; CURE;
D O I
10.1007/s00784-015-1700-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Flowable bulk-fill resin bonded composites (RBCs) are supposed to show improved abrasion resistance and fracture toughness in comparison to flowable conventional RBCs. Specimens of eight flowable RBCs (5x flowable conventional, 3x flowable bulk-fill) were fabricated for testing relative fracture toughness (SENB), relative three-body wear, the Vickers hardness, glass transition Tg (differential scanning calorimetry; DSC) and filler mass fraction (thermal gravimetric analysis; TGA). A laboratory veneering composite was used as a reference. Fracture toughness and wear values were related to this reference. Scanning electron microscope images were evaluated for fraktographical and microstructural investigations. Statistical analyses were performed using one-way Anova, the Bonferroni post hoc test and the Pearson correlation test (alpha =0.05). Relative fracture toughness varied between 0.64 and 1.34 (1.00 = 1.69 MPamA1/2) and relative wear rates between 1.24 and 0.55 (1.00 = 134 mu m). The Vickers hardness ranged between 14.4 and 57.2 HV. TGA showed filler fractions between 55 and 77 wt.%. Tg values varied between -67.8 and -40.9 A degrees C. None of the tests identified clear differences between flowable bulk-fills or conventional flowable RBCs. The Pearson correlation coefficient (cc) showed significant correlations (cc > 0.583; p < 0.001) between relative fracture toughness and hardness or filler content. There was a significant correlation (cc = 0.757; p = 0.005) between relative wear and glass transition temperature or between filler fraction and the Vickers hardness (cc > 0.702; p < 0.001). For all filler sizes breakdown was found, where clusters and pre-polymerized particles were partly disintegrated. Flowable bulk-fill RBCs showed no improved abrasion resistance and fracture toughness in comparison to flowable conventional RBCs. Differences in the properties were higher between the individual materials than between the material groups. Therefore the appropriate material selection may be essential for a clinical success.
引用
收藏
页码:2123 / 2130
页数:8
相关论文
共 50 条
  • [1] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Frank Engelhardt
    Sebastian Hahnel
    Verena Preis
    Martin Rosentritt
    [J]. Clinical Oral Investigations, 2016, 20 : 2123 - 2130
  • [2] Comparison of microleakage between bulk-fill flowable and nanofilled resin-based composites
    Alsagob, Eman I.
    Bardwell, David N.
    Ali, Ala O.
    Khayat, Samer G.
    Stark, Paul C.
    [J]. INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2018, 10 (02): : 102 - 109
  • [3] Comparison of occlusal wear between bulk-fill and conventional flowable resin composites
    Ujiie, Maho
    Tsujimoto, Akimasa
    Barkmeier, Wayne W.
    Jurado, Carlos A.
    Villalobos-Tinoco, Jose
    Takamizawa, Toshiki
    Latta, Mark A.
    Miyazaki, Masashi
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (02): : 74 - 78
  • [4] Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites
    Yilmaz, E. C.
    Sadeler, R.
    [J]. MECHANICS OF COMPOSITE MATERIALS, 2018, 54 (03) : 395 - 402
  • [5] Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites
    E. Ç. Yilmaz
    R. Sadeler
    [J]. Mechanics of Composite Materials, 2018, 54 : 395 - 402
  • [6] Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites
    Marigo, L.
    Spagnuolo, G.
    Malara, F.
    Martorana, G. E.
    Cordaro, M.
    Lupi, A.
    Nocca, G.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2015, 19 (23) : 4469 - 4480
  • [7] Curing characteristics of flowable and sculptable bulk-fill composites
    Miletic, Vesna
    Pongprueksa, Pong
    De Munck, Jan
    Brooks, Neil R.
    Van Meerbeek, Bart
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1201 - 1212
  • [8] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    [J]. Clinical Oral Investigations, 2017, 21 : 1201 - 1212
  • [9] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    [J]. MEDICINA-LITHUANIA, 2024, 60 (03):
  • [10] Comparison of polymerization shrinkage of a new bulk-fill flowable composite with other composites: An in vitro study
    Tusi, Somayeh Khoramian
    Hamdollahpoor, Hajar
    Savadroodbari, Maryam Mohammadi
    Fathollahi, Mahmood Sheikh
    [J]. CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2022, 8 (06): : 1605 - 1613