Curing characteristics of flowable and sculptable bulk-fill composites

被引:59
|
作者
Miletic, Vesna [1 ,2 ,3 ]
Pongprueksa, Pong [1 ,2 ]
De Munck, Jan [1 ,2 ]
Brooks, Neil R. [4 ]
Van Meerbeek, Bart [1 ,2 ]
机构
[1] KU Leuven Univ Leuven, BIOMAT, Dept Oral Hlth Sci, Kapucijnenvoer 7,Block A Box, B-7001 Leuven, Belgium
[2] Univ Hosp Leuven, Dent, Kapucijnenvoer 7,Block A Box, B-7001 Leuven, Belgium
[3] Univ Belgrade, Sch Dent Med, Belgrade, Serbia
[4] KU Leuven Univ Leuven, Dept Chem, Leuven, Belgium
关键词
Bulk-fill; Composites; Translucency; Depth of cure; Degree of conversion; Hardness; FIBER-REINFORCED COMPOSITE; POLYMER NETWORK MATRIX; RESIN-BASED COMPOSITES; MONOWAVE LED UNITS; SURFACE MICROHARDNESS; DENTAL RESINS; CONVERSION; DEPTH; CURE; SHRINKAGE;
D O I
10.1007/s00784-016-1894-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.
引用
收藏
页码:1201 / 1212
页数:12
相关论文
共 50 条
  • [21] Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites
    Lempel, Edina
    Ori, Zsuzsanna
    Kincses, Dora
    Lovasz, Balint Viktor
    Kunsagi-Mate, Sandor
    Szalma, Jozsef
    [J]. DENTAL MATERIALS, 2021, 37 (06) : 983 - 997
  • [22] Profiling Elastoplastic and Chemical Parameters to Assess Polymerization Quality in Flowable Bulk-Fill Composites
    Ilie, Nicoleta
    [J]. BIOENGINEERING-BASEL, 2024, 11 (02):
  • [23] Oxidative Alteration in Gingival Fibroblast Cells Induced By Bulk-Fill and Conventional Flowable Composites
    Celik, Neslihan
    Yapar, Merve Iscan
    Taghizadehghalehjoughi, Ali
    [J]. MEANDROS MEDICAL AND DENTAL JOURNAL, 2018, 19 (04): : 302 - 309
  • [24] Kinetic of Light Transmission during Setting and Aging of Modern Flowable Bulk-Fill Composites
    Ilie, Nicoleta
    Hoegg, Christof
    [J]. MATERIALS, 2024, 17 (17)
  • [25] Cuspal Deflection and Temperature Rise of MOD Cavities Restored through the Bulk-Fill and Incremental Layering Techniques Using Flowable and Packable Bulk-Fill Composites
    De Santis, Roberto
    Lodato, Vincenzo
    Gallicchio, Vito
    Prisco, Davide
    Riccitiello, Francesco
    Rengo, Sandro
    Rengo, Carlo
    [J]. MATERIALS, 2020, 13 (24) : 1 - 15
  • [26] Effect of high-intensity curing lights on the polymerization of bulk-fill composites
    Daugherty, Mindy M.
    Lien, Wen
    Mansell, Michael R.
    Risk, Douglas L.
    Sauett, Daniel A.
    Vandewalle, Kraig S.
    [J]. DENTAL MATERIALS, 2018, 34 (10) : 1531 - 1541
  • [27] Influence of Curing Time on the Microbiological Behavior of Bulk-Fill Nanohybrid Resin Composites
    Ionescu, Andrei C.
    Comba, Allegra
    Brambilla, Eugenio
    Ilie, Nicoleta
    Breschi, Lorenzo
    Cadenaro, Milena
    Scotti, Nicola
    [J]. POLYMERS, 2021, 13 (17)
  • [28] Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites
    Sampaio, C. S.
    Pizarro, P. G.
    Atria, P. J.
    Hirata, R.
    Giannini, M.
    Mahn, E.
    [J]. OPERATIVE DENTISTRY, 2020, 45 (05) : 496 - 505
  • [29] Polymerization efficiency of bulk-fill dental resin composites with different curing modes
    Dionysopoulos, Dimitrios
    Tolidis, Kosmas
    Gerasimou, Paris
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2016, 133 (18)
  • [30] Physical and Mechanical Properties of Bulk-Fill, Conventional, and Flowable Resin Composites Stored Dry and Wet
    Jafarpour, Dana
    Ferooz, Reihaneh
    Ferooz, Maryam
    Bagheri, Rafat
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022