Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application

被引:21
|
作者
Kaisarly, Dalia [1 ,2 ]
El Gezawi, Moataz [3 ]
Kessler, Andreas [1 ]
Roesch, Peter [4 ]
Kunzelmann, Karl-Heinz [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodontol, Goethestr 70, D-80336 Munich, Germany
[2] Cairo Univ, Fac Oral & Dent Med, Biomat Dept, Cairo, Egypt
[3] Imam Abdulrahman Bin Faisal Univ, Dept Restorat Dent Sci, Dammam, Saudi Arabia
[4] Univ Appl Sci, Fac Comp Sci, Augsburg, Germany
关键词
Flowable bulk-fill composite; Bulk application; Incremental application; Shrinkage vectors; Total-etch technique; Medical image registration; MICROCOMPUTED TOMOGRAPHY-EVALUATION; MICRO-COMPUTED TOMOGRAPHY; POLYMERIZATION SHRINKAGE; RESIN COMPOSITE; BOND STRENGTH; CONTRACTION STRESS; DENTAL COMPOSITES; C-FACTOR; KINETICS; LEAKAGE;
D O I
10.1007/s00784-020-03412-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Sufficient depth of cure allows bulk-fill composites to be placed with a 4-mm thickness. This study investigated bulk versus incremental application methods by visualizing shrinkage vectors in flowable bulk-fill and conventional composites. Materials and methods Cylindrical cavities (diameter = 6 mm, depth = 4 mm) were prepared in 24 teeth and then etched and bonded with OptiBond FL (Kerr, Italy). The composites were mixed with 2 wt% radiolucent glass beads. In one group, smart dentin replacement (SDR, Dentsply) was applied in bulk "SDR-bulk" (n = 8). In two groups, SDR and Tetric EvoFlow (Ivoclar Vivadent) were applied in two 2-mm-thick increments: "SDR-incremental" and "EvoFlow-incremental." Each material application was scanned with a micro-CT before and after light-curing (40 s, 1100 mW/cm(2)), and the shrinkage vectors were computed via image segmentation. Thereafter, linear polymerization shrinkage, shrinkage stress and gelation time were measured (n = 10). Results The greatest shrinkage vectors were found in "SDR-bulk" and "SDR-increment2," and the smallest were found in "SDR-increment1-covered" and "EvoFlow-increment1-covered." Shrinkage away from and toward the cavity floor was greatest in "SDR-bulk" and "EvoFlow-increment2," respectively. The mean values of the shrinkage vectors were significantly different between groups (one-way ANOVA, Tamhane's T2 test,p < 0.05). The linear polymerization shrinkage and shrinkage stress were greatest in Tetric EvoFlow, and the gelation time was greatest in "SDR-bulk." Conclusions The bulk application method had greater values of shrinkage vectors and a higher debonding tendency at the cavity floor.
引用
收藏
页码:1127 / 1139
页数:13
相关论文
共 50 条
  • [1] Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application
    Dalia Kaisarly
    Moataz El Gezawi
    Andreas Keßler
    Peter Rösch
    Karl-Heinz Kunzelmann
    [J]. Clinical Oral Investigations, 2021, 25 : 1127 - 1139
  • [2] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Dalia Kaisarly
    D. Meierhofer
    M. El Gezawi
    P. Rösch
    K.H. Kunzelmann
    [J]. Clinical Oral Investigations, 2021, 25 : 4927 - 4940
  • [3] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Kaisarly, Dalia
    Meierhofer, D.
    El Gezawi, M.
    Roesch, P.
    Kunzelmann, K. H.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (08) : 4927 - 4940
  • [4] Comparison of Flexural Properties of Bulk-fill Restorative/Flowable Composites and Their Conventional Counterparts
    Eweis, A. H.
    Yap, A. U.
    Yahya, N. A.
    [J]. OPERATIVE DENTISTRY, 2020, 45 (01) : 41 - 51
  • [5] Comparison of occlusal wear between bulk-fill and conventional flowable resin composites
    Ujiie, Maho
    Tsujimoto, Akimasa
    Barkmeier, Wayne W.
    Jurado, Carlos A.
    Villalobos-Tinoco, Jose
    Takamizawa, Toshiki
    Latta, Mark A.
    Miyazaki, Masashi
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (02): : 74 - 78
  • [6] Curing characteristics of flowable and sculptable bulk-fill composites
    Miletic, Vesna
    Pongprueksa, Pong
    De Munck, Jan
    Brooks, Neil R.
    Van Meerbeek, Bart
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1201 - 1212
  • [7] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    [J]. Clinical Oral Investigations, 2017, 21 : 1201 - 1212
  • [8] Effect of bulk/incremental fill on internal gap formation of bulk-fill composites
    Furness, Alan
    Tadros, Marko Yousef
    Looney, Stephen W.
    Rueggeberg, Frederick A.
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (04) : 439 - 449
  • [9] Discoloration of Bulk-Fill Versus Conventional Composites: A Spectrophotometric Evaluation
    Serin-Kalay, Tugba
    [J]. ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (02) : 63 - 72
  • [10] Effects of application method on shrinkage vectors and volumetric shrinkage of bulk-fill composites in class-II restorations
    Kaisarly, Dalia
    Langenegger, Ruth
    Litzenburger, Friederike
    Heck, Katrin
    El Gezawi, Moataz
    Roesch, Peter
    Kunzelmann, Karl-Heinz
    [J]. DENTAL MATERIALS, 2022, 38 (01) : 79 - 93