Color Stability of Bulk-Fill Flowable Resin Composites After Artificial Aging

被引:0
|
作者
Floriani, Franciele [1 ]
Jurado, Carlos A. [2 ]
Madhu, Nikkita [1 ]
Lackey, Mark A. [2 ]
Azpiazu-Flores, Francisco X. [3 ]
Lopes, Guilherme Carpena [4 ]
机构
[1] Univ Iowa, Coll Dent, Dept Prosthodont, Iowa City, IA 52241 USA
[2] Univ Tennessee Hlth Sci Ctr, Coll Dent, Dept Gen Dent, Memphis, TN 38103 USA
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
关键词
resin composite; bulk-fill; color; flowable composite; shade; CLINICAL-PERFORMANCE; RESTORATIONS; VISCOSITY; PROFILE; TRIAL;
D O I
10.3390/dj12110350
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging. Methods: Disk-shaped specimens (& Oslash;10 x 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow, Venus Bulk-Fill Flow, and Estelite Bulk-Fill Flow). The specimens in each bulk-fill resin composite group were divided into two subgroups (n = 10 per subgroup) with two different shades, A1 (N = 30) and A3 (N = 30), and were polymerized with light curing (800 mW/cm(2)/Valo LED Unit, Ultradent) and polished. The color difference between bulk-fill resin composites was evaluated at baseline and after artificial aging using a spectrophotometer (CM-700d, Konica Minolta, Tokyo, Japan) under D65 illumination. Color coordinates were measured with CIEDE2000, and color differences (triangle E-00) and relative translucency parameter (RTP) values were calculated. Subsequently, the comparison of color changes (triangle E-00) before and after thermocycling was performed using the t-test for paired samples. Results: The bulk-fill flow resin composites evaluated in the present study were capable of mimicking important optical properties such as light transmission. All the resin composites provided acceptable color stability at baseline and after thermocycling when the color A1 was used. On the other hand, whenever the shade A3 was used, the Venus Bulk-Fill Flow demonstrated the best optical properties. There was no statistically significant difference when comparing baseline and after thermocycling in bulk-fill flowable resin composites (p > 0.05). After thermocycling, A1 bulk-fill flowable resin composites provided acceptable color stability, and all A3 bulk-fill flowable resin composites provided visible color change, except for the Venus Bulk-Fill Flow (triangle E-00 = 2.35). Conclusions: Estelite Bulk-Fill Flow displayed the best color stability (triangle E-00 = 2.22) between all the combinations evaluated.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The effect of bleaching applications on stained bulk-fill resin composites
    Erturk-Avunduk, Ayse Tugba
    Cengiz-Yanardag, Esra
    Karakaya, Izgen
    BMC ORAL HEALTH, 2022, 22 (01)
  • [42] The effect of bleaching applications on stained bulk-fill resin composites
    Ayse Tugba Erturk-Avunduk
    Esra Cengiz-Yanardag
    Izgen Karakaya
    BMC Oral Health, 22
  • [43] Bond Strength of a Flowable Bulk-fill Resin Composite in Class II MOD Cavities
    Kumagai, Rose Yakushijin
    Zeidan, Leonardo Colombo
    Rodrigues, Jose Augusto
    Reis, Andre Figueiredo
    Roulet, Jean-Francois
    JOURNAL OF ADHESIVE DENTISTRY, 2015, 17 (05): : 427 - 432
  • [44] Evaluation of surface microhardness and gingival marginal adaptation of three different bulk-fill flowable resin composites: A comparative study
    Khairy, Nourhan Medhat
    Elkholany, Naglaa Rizk
    Elembaby, Abeer Elsayed
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (06) : 920 - 929
  • [45] Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites
    de Deus, R. a
    Oliveira, L. r s
    Braga, S. s l
    Price, M. T. H. Ribeiro R. B.
    Nunez, A.
    Loguercio, A. d
    Soares, C. j
    OPERATIVE DENTISTRY, 2024, 49 (02) : 136 - 156
  • [46] Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites
    E. Ç. Yilmaz
    R. Sadeler
    Mechanics of Composite Materials, 2018, 54 : 395 - 402
  • [47] Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites
    Yilmaz, E. C.
    Sadeler, R.
    MECHANICS OF COMPOSITE MATERIALS, 2018, 54 (03) : 395 - 402
  • [48] Profiling Elastoplastic and Chemical Parameters to Assess Polymerization Quality in Flowable Bulk-Fill Composites
    Ilie, Nicoleta
    BIOENGINEERING-BASEL, 2024, 11 (02):
  • [49] Oxidative Alteration in Gingival Fibroblast Cells Induced By Bulk-Fill and Conventional Flowable Composites
    Celik, Neslihan
    Yapar, Merve Iscan
    Taghizadehghalehjoughi, Ali
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2018, 19 (04): : 302 - 309
  • [50] Incremental and Bulk-fill Techniques With Bulk-fill Resin Composite in Different Cavity Configurations
    Han, S-H
    Park, S-H
    OPERATIVE DENTISTRY, 2018, 43 (06) : 631 - 641