Evaluation of Calibration Burden for Monitoring of a Pharmaceutical Continuous Manufacturing Line using Near-Infrared Spectroscopy

被引:0
|
作者
Rish, Adam J. [1 ]
Kurt, Cassidy [2 ]
Assis, Joao Marcos [3 ]
Rehrauer, Owen [1 ]
Rangel-Gil, Raul S. [3 ,4 ]
Taylor, Edward [1 ]
机构
[1] Sentron US Corp, 8 Saddle Rd, Norwalk, CT 06851 USA
[2] GEA Pharmaceut Technol Ctr, Columbia, MD 21045 USA
[3] BASF Corp, Tarrytown, NY 10591 USA
[4] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR 00681 USA
关键词
Calibration burden; Process analytical technology (PAT); Continuous manufacturing; Multivariate data analysis; Coprocessed excipient; ITERATIVE OPTIMIZATION TECHNOLOGY; WAVELENGTH SELECTION; EXCESS ABSORPTION;
D O I
10.1016/j.ijpharm.2025.125419
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Process analytical technology (PAT) tools are an important part of process monitoring and control in pharmaceutical continuous manufacturing (CM) that help ensure product quality. However, there is hesitancy to adopt PAT due, in part, to the high start-up costs. A portion of the cost is the calibration burden associated with developing an appropriate multivariate data analysis (MVDA) method to extract the desired information from the spectral outputs of spectroscopic PAT tools. This has generated research interest in reduced calibration burden MVDA methods, such as iterative optimization technology (IOT) algorithms, as alternatives to conventional modeling approaches like partial least squares (PLS) regression. The goal of the presented research is to compare the calibration burden of three different MVDA methods (direct IOT, indirect IOT, PLS regression) at two drug loading levels (low and high) of pharmaceutical powder blends in a CM line. The blends were binary mixtures consisting of an active pharmaceutical ingredient and a coprocessed excipient blend. The coprocessed excipient blend was leveraged to reduce formulation complexity and streamline process development, benefiting the application of IOT algorithm. Calibration burden was assessed in terms of time, material, and financial costs. Utilizing a near-infrared spectroscopic PAT tool, it was found that MVDA methods that utilized IOT algorithms demonstrated a notably reduced calibration burden compared to the PLS models, while predicting blend potency with similar accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Development of Near Infrared Spectroscopy-based Process Monitoring Methodology for Pharmaceutical Continuous Manufacturing Using an Offline Calibration Approach
    Hetrick, Evan M.
    Shi, Zhenqi
    Barnes, Lukas E.
    Garrett, Aaron W.
    Rupard, Robert G.
    Kramer, Timothy T.
    Cooper, Tony M.
    Myers, David P.
    Castle, Bryan C.
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 9175 - 9183
  • [2] Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 101
  • [3] Assessment of in-line near-infrared spectroscopy for continuous monitoring of fermentation processes
    Tosi, S
    Rossi, M
    Tamburini, E
    Vaccari, G
    Amaretti, A
    Matteuzzi, D
    BIOTECHNOLOGY PROGRESS, 2003, 19 (06) : 1816 - 1821
  • [4] Comparison Between Pure Component Modeling Approaches for Monitoring Pharmaceutical Powder Blends with Near-Infrared Spectroscopy in Continuous Manufacturing Schemes
    Adam J. Rish
    Samuel R. Henson
    Md. Anik Alam
    Yang Liu
    James K. Drennen
    Carl A. Anderson
    The AAPS Journal, 24
  • [5] Comparison Between Pure Component Modeling Approaches for Monitoring Pharmaceutical Powder Blends with Near-Infrared Spectroscopy in Continuous Manufacturing Schemes
    Rish, Adam J.
    Henson, Samuel R.
    Alam, Md Anik
    Liu, Yang
    Drennen, James K.
    Anderson, Carl A.
    AAPS JOURNAL, 2022, 24 (04):
  • [6] Monitoring angiogenesis using a human compatible calibration for broadband near-infrared spectroscopy
    Yang, Runze
    Zhang, Qiong
    Wu, Ying
    Dunn, Jeff F.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [7] Efficient Near-Infrared Spectroscopic Calibration Methods for Pharmaceutical Blend Monitoring
    Brian M. Zacour
    Benoît Igne
    James K. Drennen
    Carl A. Anderson
    Journal of Pharmaceutical Innovation, 2011, 6 : 10 - 23
  • [8] Efficient Near-Infrared Spectroscopic Calibration Methods for Pharmaceutical Blend Monitoring
    Zacour, Brian M.
    Igne, Benoit
    Drennen, James K., III
    Anderson, Carl A.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2011, 6 (01) : 10 - 23
  • [9] Pharmaceutical Applications of Near-Infrared Spectroscopy
    Muselik, Jan
    CHEMICKE LISTY, 2012, 106 (01): : 10 - 15
  • [10] Near-infrared spectroscopy in the pharmaceutical industry
    Departamento de Química, Unidad de Química Analítica, Universidad Autónoma de Barcelona, E-08193 Bellaterra, Barcelona, Spain
    不详
    Analyst, 8 (135R-150R):