Evaluation of Calibration Burden for Monitoring of a Pharmaceutical Continuous Manufacturing Line using Near-Infrared Spectroscopy

被引:0
|
作者
Rish, Adam J. [1 ]
Kurt, Cassidy [2 ]
Assis, Joao Marcos [3 ]
Rehrauer, Owen [1 ]
Rangel-Gil, Raul S. [3 ,4 ]
Taylor, Edward [1 ]
机构
[1] Sentron US Corp, 8 Saddle Rd, Norwalk, CT 06851 USA
[2] GEA Pharmaceut Technol Ctr, Columbia, MD 21045 USA
[3] BASF Corp, Tarrytown, NY 10591 USA
[4] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR 00681 USA
关键词
Calibration burden; Process analytical technology (PAT); Continuous manufacturing; Multivariate data analysis; Coprocessed excipient; ITERATIVE OPTIMIZATION TECHNOLOGY; WAVELENGTH SELECTION; EXCESS ABSORPTION;
D O I
10.1016/j.ijpharm.2025.125419
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Process analytical technology (PAT) tools are an important part of process monitoring and control in pharmaceutical continuous manufacturing (CM) that help ensure product quality. However, there is hesitancy to adopt PAT due, in part, to the high start-up costs. A portion of the cost is the calibration burden associated with developing an appropriate multivariate data analysis (MVDA) method to extract the desired information from the spectral outputs of spectroscopic PAT tools. This has generated research interest in reduced calibration burden MVDA methods, such as iterative optimization technology (IOT) algorithms, as alternatives to conventional modeling approaches like partial least squares (PLS) regression. The goal of the presented research is to compare the calibration burden of three different MVDA methods (direct IOT, indirect IOT, PLS regression) at two drug loading levels (low and high) of pharmaceutical powder blends in a CM line. The blends were binary mixtures consisting of an active pharmaceutical ingredient and a coprocessed excipient blend. The coprocessed excipient blend was leveraged to reduce formulation complexity and streamline process development, benefiting the application of IOT algorithm. Calibration burden was assessed in terms of time, material, and financial costs. Utilizing a near-infrared spectroscopic PAT tool, it was found that MVDA methods that utilized IOT algorithms demonstrated a notably reduced calibration burden compared to the PLS models, while predicting blend potency with similar accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Continuous quantitative monitoring of powder mixing dynamics by near-infrared spectroscopy
    Koller, D. M.
    Posch, A.
    Hoerl, G.
    Voura, C.
    Radl, S.
    Urbanetz, N.
    Fraser, S. D.
    Tritthart, W.
    Reiter, F.
    Schlingmann, M.
    Khinast, J. G.
    POWDER TECHNOLOGY, 2011, 205 (1-3) : 87 - 96
  • [32] Near-Infrared Spectroscopy and Continuous Glucose Monitoring During Therapeutic Hypothermia
    Vagelli, Giulia
    Garbarino, Francesca
    Calevo, Maria Grazia
    Brigati, Giorgia
    Ramenghi, Luca Antonio
    NEUROTRAUMA REPORTS, 2024, 5 (01): : 13 - 15
  • [33] Noninvasive diagnosis and continuous monitoring of thrombosis in clinics by near-infrared spectroscopy
    Li, Ting
    Sun, Yunlong
    Chen, Xiao
    Zhao, Yue
    Ren, Rongrong
    Liu, Mushuang
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XIII, 2015, 9313
  • [34] PHARMACEUTICAL FERMENTATION MONITORING BY NEAR-INFRARED SPECTROMETRY
    LANGE, AJ
    SINCLAIR, SL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 102 - BIOT
  • [35] TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY
    FORINA, M
    DRAVA, G
    ARMANINO, C
    BOGGIA, R
    LANTERI, S
    LEARDI, R
    CORTI, P
    CONTI, P
    GIANGIACOMO, R
    GALLIENA, C
    BIGONI, R
    QUARTARI, I
    SERRA, C
    FERRI, D
    LEONI, O
    LAZZERI, L
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) : 189 - 203
  • [36] On-line monitoring of powder blend homogeneity by near-infrared spectroscopy
    Sekulic, SS
    Ward, HW
    Brannegan, DR
    Stanley, ED
    Evans, CL
    Sciavolino, ST
    Hailey, PA
    Aldridge, PK
    ANALYTICAL CHEMISTRY, 1996, 68 (03) : 509 - 513
  • [37] On-line monitoring of starch enzymatic hydrolysis by near-infrared spectroscopy
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Banó, RG
    ANALYST, 2000, 125 (04) : 749 - 752
  • [38] NEAR-INFRARED SPECTROSCOPY IN FETAL MONITORING
    OBRIEN, PMS
    DOYLE, PM
    ROLFE, P
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (07): : 483 - &
  • [39] Evaluation method for proteoglycans using near-infrared spectroscopy
    Nakamura, Fumiya
    Ikemizu, Tomoki
    Murao, Miu
    Isoshima, Takashi
    Kobayashi, Daiji
    Mitomo, Hideyuki
    Ijiro, Kuniharu
    Kimura-Suda, Hiromi
    ANALYTICAL SCIENCES, 2025, : 395 - 401
  • [40] Continuous Monitoring of Buried Free Bone Flap Microcirculation Using a Near-Infrared Spectroscopy System
    Ma, Yixin
    Li, Shijun
    Shan, Xiaofeng
    Zhang, Lei
    Cai, Zhigang
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 153 (03) : 626e - 631e