Evaluation of Calibration Burden for Monitoring of a Pharmaceutical Continuous Manufacturing Line using Near-Infrared Spectroscopy

被引:0
|
作者
Rish, Adam J. [1 ]
Kurt, Cassidy [2 ]
Assis, Joao Marcos [3 ]
Rehrauer, Owen [1 ]
Rangel-Gil, Raul S. [3 ,4 ]
Taylor, Edward [1 ]
机构
[1] Sentron US Corp, 8 Saddle Rd, Norwalk, CT 06851 USA
[2] GEA Pharmaceut Technol Ctr, Columbia, MD 21045 USA
[3] BASF Corp, Tarrytown, NY 10591 USA
[4] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR 00681 USA
关键词
Calibration burden; Process analytical technology (PAT); Continuous manufacturing; Multivariate data analysis; Coprocessed excipient; ITERATIVE OPTIMIZATION TECHNOLOGY; WAVELENGTH SELECTION; EXCESS ABSORPTION;
D O I
10.1016/j.ijpharm.2025.125419
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Process analytical technology (PAT) tools are an important part of process monitoring and control in pharmaceutical continuous manufacturing (CM) that help ensure product quality. However, there is hesitancy to adopt PAT due, in part, to the high start-up costs. A portion of the cost is the calibration burden associated with developing an appropriate multivariate data analysis (MVDA) method to extract the desired information from the spectral outputs of spectroscopic PAT tools. This has generated research interest in reduced calibration burden MVDA methods, such as iterative optimization technology (IOT) algorithms, as alternatives to conventional modeling approaches like partial least squares (PLS) regression. The goal of the presented research is to compare the calibration burden of three different MVDA methods (direct IOT, indirect IOT, PLS regression) at two drug loading levels (low and high) of pharmaceutical powder blends in a CM line. The blends were binary mixtures consisting of an active pharmaceutical ingredient and a coprocessed excipient blend. The coprocessed excipient blend was leveraged to reduce formulation complexity and streamline process development, benefiting the application of IOT algorithm. Calibration burden was assessed in terms of time, material, and financial costs. Utilizing a near-infrared spectroscopic PAT tool, it was found that MVDA methods that utilized IOT algorithms demonstrated a notably reduced calibration burden compared to the PLS models, while predicting blend potency with similar accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] MICROBIAL FERMENTATION MONITORING USING NEAR-INFRARED SPECTROSCOPY
    HE, M
    LORR, D
    WANG, NS
    AMERICAN BIOTECHNOLOGY LABORATORY, 1993, 11 (08): : 56 - 57
  • [22] Monitoring of methanogen density using near-infrared spectroscopy
    Zhang, YS
    Zhang, ZY
    Sugiura, N
    Maekawa, T
    BIOMASS & BIOENERGY, 2002, 22 (06): : 489 - 495
  • [23] At-line monitoring of a submerged filamentous bacterial cultivation using near-infrared spectroscopy
    Arnold, SA
    Crowley, J
    Vaidyanathan, S
    Matheson, L
    Mohan, P
    Hall, JW
    Harvey, LM
    McNeil, B
    ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (09) : 691 - 697
  • [24] On-Line Monitoring of Enzymatic Degumming of Soybean Oil Using Near-Infrared Spectroscopy
    Tonolini, Margherita
    Wawrzynczyk, Joanna
    Nielsen, Per Munk
    Engelsen, Soren Balling
    APPLIED SPECTROSCOPY, 2023, 77 (12) : 1333 - 1343
  • [25] Chemometric evaluation of pharmaceutical properties of antipyrine granules by near-infrared spectroscopy
    Makoto Otsuka
    Yoshifumi Mouri
    Yoshihisa Matsuda
    AAPS PharmSciTech, 4 (3)
  • [26] Continuous manufacturing of pharmaceutical products: A density-insensitive near infrared method for the in-line monitoring of continuous powder streams
    Velez-Silva, Natasha L.
    Drennen III, James K.
    Anderson, Carl A.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 650
  • [27] USES OF NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL ANALYSIS
    CIURCZAK, EW
    APPLIED SPECTROSCOPY REVIEWS, 1987, 23 (1-2) : 147 - 163
  • [28] Near-infrared spectroscopy applications in pharmaceutical analysis
    Luypaert, J.
    Massart, D. L.
    Heyden, Y. Vander
    TALANTA, 2007, 72 (03) : 865 - 883
  • [29] Application of the near-infrared spectroscopy in the pharmaceutical technology
    Jamrogiewicz, Marzena
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 1 - 10
  • [30] Monitoring for compartmental syndrome using near-infrared spectroscopy: A noninvasive, continuous, transcutaneous monitoring technique - Discussion
    Knudson, MM
    Moore, FA
    Puyana, JC
    Rabinovici, R
    Garr, J
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 46 (04): : 617 - 618