Evaluation of Calibration Burden for Monitoring of a Pharmaceutical Continuous Manufacturing Line using Near-Infrared Spectroscopy

被引:0
|
作者
Rish, Adam J. [1 ]
Kurt, Cassidy [2 ]
Assis, Joao Marcos [3 ]
Rehrauer, Owen [1 ]
Rangel-Gil, Raul S. [3 ,4 ]
Taylor, Edward [1 ]
机构
[1] Sentron US Corp, 8 Saddle Rd, Norwalk, CT 06851 USA
[2] GEA Pharmaceut Technol Ctr, Columbia, MD 21045 USA
[3] BASF Corp, Tarrytown, NY 10591 USA
[4] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR 00681 USA
关键词
Calibration burden; Process analytical technology (PAT); Continuous manufacturing; Multivariate data analysis; Coprocessed excipient; ITERATIVE OPTIMIZATION TECHNOLOGY; WAVELENGTH SELECTION; EXCESS ABSORPTION;
D O I
10.1016/j.ijpharm.2025.125419
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Process analytical technology (PAT) tools are an important part of process monitoring and control in pharmaceutical continuous manufacturing (CM) that help ensure product quality. However, there is hesitancy to adopt PAT due, in part, to the high start-up costs. A portion of the cost is the calibration burden associated with developing an appropriate multivariate data analysis (MVDA) method to extract the desired information from the spectral outputs of spectroscopic PAT tools. This has generated research interest in reduced calibration burden MVDA methods, such as iterative optimization technology (IOT) algorithms, as alternatives to conventional modeling approaches like partial least squares (PLS) regression. The goal of the presented research is to compare the calibration burden of three different MVDA methods (direct IOT, indirect IOT, PLS regression) at two drug loading levels (low and high) of pharmaceutical powder blends in a CM line. The blends were binary mixtures consisting of an active pharmaceutical ingredient and a coprocessed excipient blend. The coprocessed excipient blend was leveraged to reduce formulation complexity and streamline process development, benefiting the application of IOT algorithm. Calibration burden was assessed in terms of time, material, and financial costs. Utilizing a near-infrared spectroscopic PAT tool, it was found that MVDA methods that utilized IOT algorithms demonstrated a notably reduced calibration burden compared to the PLS models, while predicting blend potency with similar accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Near-infrared spectroscopy in the pharmaceutical industry
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    de la Pezuela, C
    ANALYST, 1998, 123 (08) : 135R - 150R
  • [12] PHARMACEUTICAL USES OF NEAR-INFRARED SPECTROSCOPY
    MORISSEAU, KM
    RHODES, CT
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1995, 21 (09) : 1071 - 1090
  • [13] Calibration models for determination of water content in pharmaceutical excipients using near-infrared spectroscopy (NIRS)
    Beyer, J
    Steffens, KJ
    PHARMAZEUTISCHE INDUSTRIE, 2003, 65 (02): : 186 - 192
  • [14] Characterization of Near-Infrared and Raman Spectroscopy for In-Line Monitoring of a Low-Drug Load Formulation in a Continuous Manufacturing Process
    Harms, Zachary D.
    Shi, Zhenqi
    Kulkarni, Rajesh A.
    Myers, David P.
    ANALYTICAL CHEMISTRY, 2019, 91 (13) : 8045 - 8053
  • [15] Evaluation of near-infrared spectroscopy for bioreactor monitoring.
    Rhiel, M
    Riley, MR
    Arnold, MA
    Murhammer, DW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 171 - BIOT
  • [16] Continuous monitoring of kidney transplant perfusion with near-infrared spectroscopy
    Malakasioti, Georgia
    Marks, Stephen D.
    Watson, Tom
    Williams, Fariba
    Taylor-Allkins, Mariesa
    Mamode, Nizam
    Morgan, Justin
    Hayes, Wesley N.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 (10) : 1863 - 1869
  • [17] Nonlinear calibration for near-infrared spectroscopy
    Dadhe, K
    CHEMICAL ENGINEERING & TECHNOLOGY, 2004, 27 (09) : 946 - 950
  • [18] Monitoring for compartmental syndrome using near-infrared spectroscopy: A noninvasive, continuous, transcutaneous monitoring technique
    Garr, JL
    Gentilello, LM
    Cole, PA
    Mock, CN
    Matsen, FA
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 46 (04): : 613 - 616
  • [19] On-line monitoring of powder blending with near-infrared spectroscopy
    De Maesschalck, R
    Sanchez, FC
    Massart, DL
    Doherty, P
    Hailey, P
    APPLIED SPECTROSCOPY, 1998, 52 (05) : 725 - 731
  • [20] Evaluation of diesel exhaust fluid (DEF) using near-infrared spectroscopy and multivariate calibration
    de Franca, Higor Henrique
    da Silva, Neirivaldo Cavalcante
    Honorato, Fernanda Araujo
    MICROCHEMICAL JOURNAL, 2019, 150