Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy

被引:1
|
作者
Koyanagi, Keita [1 ]
Shoji, Kippei [2 ]
Ueno, Akinori [1 ]
Sasaki, Tetsuo [2 ,3 ,4 ]
Otsuka, Makoto [1 ,4 ]
机构
[1] Earthtech Corp Ltd, 1780 Kamikouya, Yachiyo, Chiba 2760022, Japan
[2] Shizuoka Univ, Grad Sch Integrated Sci & Technol, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[4] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Cyuo ku, Hamamatsu 4328011, Japan
关键词
Fully flow-type continuous manufacturing sys-; tem; Process analytical technology; Real-time-monitoring; Near-infrared spectroscopy; Acetaminophen; Partial least squares regression analysis; Critical quality attribute; Critical process parameter; WET-GRANULATION; HIGH-SHEAR; QUALITY; IMPELLER; FUTURE; DESIGN; BATCH;
D O I
10.1016/j.jddst.2024.106240
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Granules for tableting were continuously manufactured using a fully flow-type continuous wet-granulation and drying (CGD) line system, "LaVortex (R)." The raw material powder containing standard excipients and 28.8 % acetaminophen was mixed with a binder liquid (pure water), continuously wet-granulated, and dried for 600 s under 20 different granulation/drying process conditions, and the process was monitored in real-time using nearinfrared (NIR) spectroscopy. Twenty granulation/drying process conditions, varying across three parameters, namely added binding water rate, agitation blades and container rotational rates, and hot drying air flow rate, were applied. Training datasets from NIR spectroscopy stably measured during the CGD process were used to construct calibration models to predict the various critical quality attributes (CQAs) of granules, such as residual moisture content, median particle size, angle of repose, and tablet hardness, using partial least squares regression (PLSR). Optimal calibration models were validated using the NIR spectroscopy test dataset. The actual granule CQA profiles evaluated using the NIR/PLSR method were almost constant up to 600 s at the end of production depending on the critical process parameters (CPPs), except for fluctuations in the initial process. These results indicate that tableting granules with various pharmaceutical properties could be obtained continuously depending on CQAs, such as the rate of water addition. Additionally, changes in CQAs could be continuously monitored by the NIR/PLSR method. Furthermore, CGD granules with various characteristic CQAs can be continuously manufactured by controlling CPPs, such as agitation blades and tube rotation rates in the agitating granulation process and drying air flow rate in the drying process under NIR spectroscopy.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Real-time monitoring of particle size distribution in a continuous granulation and drying process by near infrared spectroscopy
    Pauli, Victoria
    Roggo, Yves
    Kleinebudde, Peter
    Krumme, Markus
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2019, 141 : 90 - 99
  • [2] Comparing integrated continuous process ?LaVortex?? and conventional batch processes for the pharmaceutical manufacturing of acetaminophen oral dosage formulations: Challenges and pharmaceutical properties of the granular and tableted products
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 638
  • [3] Evaluation of Calibration Burden for Monitoring of a Pharmaceutical Continuous Manufacturing Line using Near-Infrared Spectroscopy
    Rish, Adam J.
    Kurt, Cassidy
    Assis, Joao Marcos
    Rehrauer, Owen
    Rangel-Gil, Raul S.
    Taylor, Edward
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2025, 673
  • [4] Real-time monitoring of integrated continuous granulation/drying line system (vol 101, 106240, 2024)
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 102
  • [5] Near-infrared spectroscopy as continuous real-time monitoring for kidney graft perfusion
    Enrico Vidal
    Angela Amigoni
    Valentina Brugnolaro
    Giulia Ghirardo
    Piergiorgio Gamba
    Andrea Pettenazzo
    Giovanni Franco Zanon
    Chiara Cosma
    Mario Plebani
    Luisa Murer
    Pediatric Nephrology, 2014, 29 : 909 - 914
  • [6] NEAR-INFRARED SPECTROSCOPY AS A CONTINUOUS REAL-TIME MONITORING FOR KIDNEY GRAFT PERFUSION
    Vidal, Enrico
    Amigoni, Angela
    Varagnolo, Mariacristina
    Benetti, Elisa
    Ghirardo, Giulia
    Brugnolaro, Valentina
    Murer, Luisa
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 548 - 548
  • [7] Near-infrared spectroscopy as continuous real-time monitoring for kidney graft perfusion
    Vidal, Enrico
    Amigoni, Angela
    Brugnolaro, Valentina
    Ghirardo, Giulia
    Gamba, Piergiorgio
    Pettenazzo, Andrea
    Zanon, Giovanni Franco
    Cosma, Chiara
    Plebani, Mario
    Murer, Luisa
    PEDIATRIC NEPHROLOGY, 2014, 29 (05) : 909 - 914
  • [8] Real-time monitoring of distillations by near-infrared spectroscopy
    Pasquini, C
    Scafi, SHF
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2270 - 2275
  • [9] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation–Drying–Milling Process
    Lipika Chablani
    Michael K. Taylor
    Amit Mehrotra
    Patrick Rameas
    William C. Stagner
    AAPS PharmSciTech, 2011, 12 : 1050 - 1055
  • [10] REAL-TIME MONITORING OF POLYURETHANE PRODUCTION USING NEAR-INFRARED SPECTROSCOPY
    DETHOMAS, FA
    HALL, JW
    MONFRE, SL
    TALANTA, 1994, 41 (03) : 425 - 431