Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy

被引:1
|
作者
Koyanagi, Keita [1 ]
Shoji, Kippei [2 ]
Ueno, Akinori [1 ]
Sasaki, Tetsuo [2 ,3 ,4 ]
Otsuka, Makoto [1 ,4 ]
机构
[1] Earthtech Corp Ltd, 1780 Kamikouya, Yachiyo, Chiba 2760022, Japan
[2] Shizuoka Univ, Grad Sch Integrated Sci & Technol, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[4] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Cyuo ku, Hamamatsu 4328011, Japan
关键词
Fully flow-type continuous manufacturing sys-; tem; Process analytical technology; Real-time-monitoring; Near-infrared spectroscopy; Acetaminophen; Partial least squares regression analysis; Critical quality attribute; Critical process parameter; WET-GRANULATION; HIGH-SHEAR; QUALITY; IMPELLER; FUTURE; DESIGN; BATCH;
D O I
10.1016/j.jddst.2024.106240
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Granules for tableting were continuously manufactured using a fully flow-type continuous wet-granulation and drying (CGD) line system, "LaVortex (R)." The raw material powder containing standard excipients and 28.8 % acetaminophen was mixed with a binder liquid (pure water), continuously wet-granulated, and dried for 600 s under 20 different granulation/drying process conditions, and the process was monitored in real-time using nearinfrared (NIR) spectroscopy. Twenty granulation/drying process conditions, varying across three parameters, namely added binding water rate, agitation blades and container rotational rates, and hot drying air flow rate, were applied. Training datasets from NIR spectroscopy stably measured during the CGD process were used to construct calibration models to predict the various critical quality attributes (CQAs) of granules, such as residual moisture content, median particle size, angle of repose, and tablet hardness, using partial least squares regression (PLSR). Optimal calibration models were validated using the NIR spectroscopy test dataset. The actual granule CQA profiles evaluated using the NIR/PLSR method were almost constant up to 600 s at the end of production depending on the critical process parameters (CPPs), except for fluctuations in the initial process. These results indicate that tableting granules with various pharmaceutical properties could be obtained continuously depending on CQAs, such as the rate of water addition. Additionally, changes in CQAs could be continuously monitored by the NIR/PLSR method. Furthermore, CGD granules with various characteristic CQAs can be continuously manufactured by controlling CPPs, such as agitation blades and tube rotation rates in the agitating granulation process and drying air flow rate in the drying process under NIR spectroscopy.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process
    Chablani, Lipika
    Taylor, Michael K.
    Mehrotra, Amit
    Rameas, Patrick
    Stagner, William C.
    AAPS PHARMSCITECH, 2011, 12 (04): : 1050 - 1055
  • [12] PAT Implementation on a Mobile Continuous Pharmaceutical Manufacturing System: Real-Time Process Monitoring with In-Line FTIR and Raman Spectroscopy
    Miyai, Yuma
    Formosa, Anna
    Armstrong, Cameron
    Marquardt, Brian
    Rogers, Luke
    Roper, Thomas
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2021, 25 (12) : 2707 - 2717
  • [13] Development of a real-time blood damage monitoring device for cardiopulmonary bypass system using near-infrared spectroscopy
    Xuelian Gu
    Taotao Wang
    Kang Zheng
    Ziang Jiang
    Hongyan Jiang
    Lasers in Medical Science, 2021, 36 : 783 - 790
  • [14] Development of a real-time blood damage monitoring device for cardiopulmonary bypass system using near-infrared spectroscopy
    Gu, Xuelian
    Wang, Taotao
    Zheng, Kang
    Jiang, Ziang
    Jiang, Hongyan
    LASERS IN MEDICAL SCIENCE, 2021, 36 (04) : 783 - 790
  • [15] Real-time monitoring of granule properties during high shear wet granulation by near-infrared spectroscopy with a chemometrics approach
    Shikata, F.
    Kimura, S.
    Hattori, Y.
    Otsuka, M.
    RSC ADVANCES, 2017, 7 (61): : 38307 - 38317
  • [16] Real-time cerebral monitoring using multichannel near-infrared spectroscopy in total arch replacement
    Yasushige Shingu
    Kazuhiro Myojin
    Yoshimitsu Ishibashi
    Kouji Ishii
    Masakazu Kawasaki
    Genbu Yamaura
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2003, 51 (4) : 154 - 157
  • [17] Quantitative real-time monitoring of dryer effluent using fiber optic near-infrared spectroscopy
    Harris, SC
    Walker, DS
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2000, 89 (09) : 1180 - 1186
  • [18] FEASIBILITY OF REAL-TIME NEAR-INFRARED SPECTROSCOPY MONITORING DURING TRACHEAL INTUBATION
    Al-Subu, Awni
    Hagen, Scott
    Hsieh, Ting-Chang
    Lasarev, Michael
    CRITICAL CARE MEDICINE, 2024, 52
  • [19] Real-Time Monitoring of Yogurt Fermentation Process by Aquaphotomics Near-Infrared Spectroscopy
    Muncan, Jelena
    Tei, Kyoko
    Tsenkova, Roumiana
    SENSORS, 2021, 21 (01) : 1 - 18
  • [20] Near-infrared spectroscopic method for real-time monitoring of pharmaceutical powders during voiding
    Barajas, Martha J.
    Cassiani, Alex Rodriguez
    Vargas, Wandylis
    Conde, Carlos
    Ropero, Jorge
    Figueroa, Jorge
    Romanach, Rodolfo J.
    APPLIED SPECTROSCOPY, 2007, 61 (05) : 490 - 496