Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy

被引:1
|
作者
Koyanagi, Keita [1 ]
Shoji, Kippei [2 ]
Ueno, Akinori [1 ]
Sasaki, Tetsuo [2 ,3 ,4 ]
Otsuka, Makoto [1 ,4 ]
机构
[1] Earthtech Corp Ltd, 1780 Kamikouya, Yachiyo, Chiba 2760022, Japan
[2] Shizuoka Univ, Grad Sch Integrated Sci & Technol, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[4] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Cyuo ku, Hamamatsu 4328011, Japan
关键词
Fully flow-type continuous manufacturing sys-; tem; Process analytical technology; Real-time-monitoring; Near-infrared spectroscopy; Acetaminophen; Partial least squares regression analysis; Critical quality attribute; Critical process parameter; WET-GRANULATION; HIGH-SHEAR; QUALITY; IMPELLER; FUTURE; DESIGN; BATCH;
D O I
10.1016/j.jddst.2024.106240
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Granules for tableting were continuously manufactured using a fully flow-type continuous wet-granulation and drying (CGD) line system, "LaVortex (R)." The raw material powder containing standard excipients and 28.8 % acetaminophen was mixed with a binder liquid (pure water), continuously wet-granulated, and dried for 600 s under 20 different granulation/drying process conditions, and the process was monitored in real-time using nearinfrared (NIR) spectroscopy. Twenty granulation/drying process conditions, varying across three parameters, namely added binding water rate, agitation blades and container rotational rates, and hot drying air flow rate, were applied. Training datasets from NIR spectroscopy stably measured during the CGD process were used to construct calibration models to predict the various critical quality attributes (CQAs) of granules, such as residual moisture content, median particle size, angle of repose, and tablet hardness, using partial least squares regression (PLSR). Optimal calibration models were validated using the NIR spectroscopy test dataset. The actual granule CQA profiles evaluated using the NIR/PLSR method were almost constant up to 600 s at the end of production depending on the critical process parameters (CPPs), except for fluctuations in the initial process. These results indicate that tableting granules with various pharmaceutical properties could be obtained continuously depending on CQAs, such as the rate of water addition. Additionally, changes in CQAs could be continuously monitored by the NIR/PLSR method. Furthermore, CGD granules with various characteristic CQAs can be continuously manufactured by controlling CPPs, such as agitation blades and tube rotation rates in the agitating granulation process and drying air flow rate in the drying process under NIR spectroscopy.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Real-time monitoring of the drying of extruded granules in a fluidised bed using near infrared spectroscopy and kinetic evaluation of the drying process
    Hayashi, Yoshihiro
    Sato, Takaya
    Otsuka, Makoto
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2013, 21 (02) : 107 - 115
  • [32] Evaluation of Three Approaches for Real-Time Monitoring of Roller Compaction with Near-Infrared Spectroscopy
    David Acevedo
    Ariel Muliadi
    Arun Giridhar
    James D. Litster
    Rodolfo J. Romañach
    AAPS PharmSciTech, 2012, 13 : 1005 - 1012
  • [33] Evaluation of Three Approaches for Real-Time Monitoring of Roller Compaction with Near-Infrared Spectroscopy
    Acevedo, David
    Muliadi, Ariel
    Giridhar, Arun
    Litster, James D.
    Romanach, Rodolfo J.
    AAPS PHARMSCITECH, 2012, 13 (03): : 1005 - 1012
  • [34] REAL-TIME MONITORING OF STYRENE AND METHYL-METHACRYLATE POLYMERIZATION WITH NEAR-INFRARED SPECTROSCOPY
    CHANG, SY
    WANG, NS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 236 - PMSE
  • [35] A real-time gesture recognition system using near-infrared imagery
    Mantecon, Tomas
    del-Blanco, Carlos R.
    Jaureguizar, Fernando
    Garcia, Narciso
    PLOS ONE, 2019, 14 (10):
  • [36] Real-time monitoring and fault detection of pulsed-spray fluid-bed granulation using near-infrared spectroscopy and multivariate process trajectories
    Zhao, Jie
    Li, Wenlong
    Qu, Haibin
    Tian, Geng
    Wei, Yanding
    PARTICUOLOGY, 2020, 53 : 112 - 123
  • [37] Comparative study on the real-time monitoring of a fluid bed drying process of extruded granules using near-infrared spectroscopy and audible acoustic emission
    Aoki, Hisayoshi
    Hattori, Yusuke
    Sasaki, Tetsuo
    Otsuka, Makoto
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 619
  • [38] Real time in-line monitoring of large scale Bacillus fermentations with near-infrared spectroscopy
    Alves-Rausch, Jose
    Bienert, Roland
    Grimm, Christian
    Bergmaier, Dirk
    JOURNAL OF BIOTECHNOLOGY, 2014, 189 : 120 - 128
  • [39] Real-time Monitoring of Powder Blend Composition using Near Infrared Spectroscopy
    O'Mahony, Niall
    Murphy, Trevor
    Panduru, Krishna
    Riordan, Daniel
    Walsh, Joseph
    2017 ELEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2017, : 123 - 128
  • [40] A process monitoring microreactor assembly for real-time reaction analysis using inline near-infrared spectroscopy and chemometrics
    Mahler, Lukas
    Desel, Pascal
    Sladkov, Marcel
    Roppertz, Andreas
    Mayer, Christian
    Jaeger, Martin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1431 - 1439