Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation–Drying–Milling Process

被引:0
|
作者
Lipika Chablani
Michael K. Taylor
Amit Mehrotra
Patrick Rameas
William C. Stagner
机构
[1] Campbell University,College of Pharmacy and Health Sciences, Department of Pharmaceutical Sciences
[2] Graduate Program Mercer University,College of Pharmacy and Health Sciences
[3] BioDelivery Sciences,Pharma Launch and Global Supply
[4] GlaxoSmithKline,Pharmaceutical Development
[5] GlaxoSmithKline,undefined
来源
AAPS PharmSciTech | 2011年 / 12卷
关键词
continuous granulation–drying–milling; near-infrared (NIR) spectroscopy; process analytical technology (PAT); real-time moisture determination;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this research was to use inline real-time near-infrared (NIR) to measure the moisture content of granules manufactured using a commercial production scale continuous twin-screw granulator fluid-bed dryer milling process. A central composite response surface statistical design was used to study the effect of inlet air temperature and dew point on granule moisture content. The NIR moisture content was compared to Karl Fischer (KF) and loss on drying (LOD) moisture determinations. Using multivariate analysis, the data showed a statistically significant correlation between the conventional methods and NIR. The R2 values for predicted moisture content by NIR versus KF and predicted moisture values by NIR versus LOD were 0.94 (p < 0.00001) and 0.85 (p < 0.0002), respectively. The adjusted R2 for KF versus LOD correlation was 0.85 (p < 0.0001). Analysis of the response surface design data showed that inlet air temperature over a range of 35–55°C had a significant linear impact on granule moisture content as measured by predicted NIR (adjusted R2 = 0.84, p < 0.02), KF (adjusted R2 = 0.91, p < 0.0001), and LOD (adjusted R2 = 0.85, p < 0.0006). The inlet air dew point range of 10–20°C did not have a significant impact on any of the moisture measurements.
引用
收藏
页码:1050 / 1055
页数:5
相关论文
共 50 条
  • [1] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process
    Chablani, Lipika
    Taylor, Michael K.
    Mehrotra, Amit
    Rameas, Patrick
    Stagner, William C.
    AAPS PHARMSCITECH, 2011, 12 (04): : 1050 - 1055
  • [2] Real-time monitoring of particle size distribution in a continuous granulation and drying process by near infrared spectroscopy
    Pauli, Victoria
    Roggo, Yves
    Kleinebudde, Peter
    Krumme, Markus
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2019, 141 : 90 - 99
  • [3] Real-time monitoring of granule properties during high shear wet granulation by near-infrared spectroscopy with a chemometrics approach
    Shikata, F.
    Kimura, S.
    Hattori, Y.
    Otsuka, M.
    RSC ADVANCES, 2017, 7 (61): : 38307 - 38317
  • [4] A process monitoring microreactor assembly for real-time reaction analysis using inline near-infrared spectroscopy and chemometrics
    Mahler, Lukas
    Desel, Pascal
    Sladkov, Marcel
    Roppertz, Andreas
    Mayer, Christian
    Jaeger, Martin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1431 - 1439
  • [5] A process monitoring microreactor assembly for real-time reaction analysis using inline near-infrared spectroscopy and chemometricsA process monitoring microreactor assembly for real-time reaction analysis using inline near-infrared spectroscopy and chemometricsL. Mahler et al.
    Lukas Mahler
    Pascal Desel
    Marcel Sladkov
    Andreas Roppertz
    Christian Mayer
    Martin Jaeger
    Analytical and Bioanalytical Chemistry, 2025, 417 (8) : 1431 - 1439
  • [6] Continuous Twin-Screw wet granulation process with In-Barrel drying and NIR setup for Real-Time Moisture Monitoring
    Haser, Abbe
    Kittikunakorn, Nada
    Dippold, Erin
    DiNunzio, James C.
    Blincoe, William
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 630
  • [7] Capacitance and near-infrared techniques for the real-time moisture measurement of broiler litter
    Virk, Simerjeet S.
    Fulton, John P.
    Fasina, Oladiran O.
    McDonald, Timothy P.
    BIOSYSTEMS ENGINEERING, 2013, 116 (04) : 357 - 367
  • [8] Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 101
  • [9] Assessment of Robustness for a Near-Infrared Concentration Model for Real-Time Release Testing in a Continuous Manufacturing Process
    Yleana M. Colón
    Jenny Vargas
    Eric Sánchez
    Gilfredo Navarro
    Rodolfo J. Romañach
    Journal of Pharmaceutical Innovation, 2017, 12 : 14 - 25
  • [10] Assessment of Robustness for a Near-Infrared Concentration Model for Real-Time Release Testing in a Continuous Manufacturing Process
    Colon, Yleana M.
    Vargas, Jenny
    Sanchez, Eric
    Navarro, Gilfredo
    Romanach, Rodolfo J.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2017, 12 (01) : 14 - 25