Scanning electron microscopy analysis of metallic and aesthetic bracket meshes before and after debonding

被引:0
|
作者
Rodriguez-Chavez, Jacqueline Adelina [1 ]
Flores-Ruiz, Hugo Marcelo [2 ]
Flores-Ledesma, Abigailt [3 ]
Garcia-Perez, Alvaro [4 ]
Bazan-Diaz, Lourdes [5 ]
机构
[1] Univ Guadalajara, Univ Ctr Hlth Sci, Inst Dent Res, Dept Integral Dent Clin, Guadalajara, Mexico
[2] Univ Guadalajara, CUValles, Dept Nat & Exact Sci, Ameca, Mexico
[3] Meritorious Autonomous Univ Puebla, Lab Dent Mat & Biomat, Puebla, Mexico
[4] Natl Autonomous Univ Mexico UNAM, Lab Publ Hlth Res, Tlalnepantla, Mexico
[5] Univ Nacl Autonoma Mexico, Mat Res Inst, Mexico City, Mexico
关键词
Bracket; Adhesive; Shear bond strength; Scanning electron microscopy; SHEAR BOND STRENGTH; CERAMIC BRACKETS; BASE DESIGN;
D O I
10.4041/kjod24.073
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To study the influence of bracket base meshes on shear bond strength and observe them using a scanning electron microscopy (SEM) before and after debonding. Methods: Ninety brackets were divided into nine groups Series Flexx 2G (R). Groups G1 to G6 and G7 to G9 consisted of metallic and aesthetic brackets, respectively. Initial photographs of all brackets were taken through SEM at 25X magnification. The brackets were then bonded to premolars using TransbondTM XT, and a shear bond strength test was conducted after 24 hours using an Instron machine at 1 mm/min. After debonding, the bracket meshes were observed using SEM. Results: Before bonding, 72.22% of brackets didn't present mesh defects, while 27.77% did. SEM analysis revealed that G4 and G5 presented defects in 100%, G7 in 40%, and G8 in 10%. The average shear bond strength of 9.67 +/- 2.84 MPa and 11.21 +/- 4.99 MPa were obtained for both metallic and aesthetic brackets, respectively. A Pairwise-Wilcoxon test with Benjamini-Hochberg correction was conducted to determine specific statistical differences between the groups, revealing significant differences based on bracket type and shear bond strength (P < 0.009). Conclusions: This study suggested that the shape of bracket meshes influenced shear bond strength.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [1] Evaluation of enamel surfaces after bracket debonding: An in-vivo study with scanning electron microscopy
    Bonetti, Giulio Alessandri
    Zanarini, Matteo
    Parenti, Serena Incerti
    Lattuca, Monica
    Marchionni, Silvia
    Gatto, Maria Rosaria
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 696 - 702
  • [2] SCANNING ELECTRON MICROSCOPY OF CONTACT SURFACES BEFORE AND AFTER ARCING
    VASILE, MJ
    KAMMLOTT, GW
    IEEE TRANSACTIONS ON PARTS HYBRIDS AND PACKAGING, 1971, PMP7 (01): : 16 - &
  • [4] Stereomicroscope analysis of enamel surface after orthodontic bracket debonding
    Miksic, M
    Slaj, M
    Mestrovic, S
    COLLEGIUM ANTROPOLOGICUM, 2003, 27 : 83 - 89
  • [5] Evaluation of enamel surface roughness after orthodontic bracket debonding with atomic force microscopy
    Mohebi, Shadi
    Shafiee, Hassan-Ali
    Ameli, Nazila
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (03) : 521 - 527
  • [6] Comparative study of dental enamel loss after debonding braces by analytical scanning electron microscopy (SEM)
    Adelina Rodriguez-Chavez, Jacqueline
    Arenas-Alatorre, Jesus
    Belio-Reyes, Irma Araceli
    MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (07) : 680 - 686
  • [7] Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives
    Rodriguez-Chavez, Jacqueline Adelina
    Arenas-Alatorre, Jesus Angel
    Flores-Ruiz, Hugo M.
    Flores-Ledesma, Abigailt
    Aguilar-Perez, Fernando Javier
    MICROSCOPY RESEARCH AND TECHNIQUE, 2021, 84 (05) : 912 - 920
  • [8] METALLIC REPLICA TECHNIQUE FOR SCANNING ELECTRON-MICROSCOPY
    WU, W
    ARGON, AS
    TURNER, APL
    JOURNAL OF MATERIALS SCIENCE, 1973, 8 (11) : 1670 - 1672
  • [9] A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems
    Nahidh, Mohammed
    Yassir, Yassir A.
    Marrapodi, Maria Maddalena
    Di Blasio, Marco
    Ronsivalle, Vincenzo
    Cicciu, Marco
    Minervini, Giuseppe
    BMC ORAL HEALTH, 2024, 24 (01)
  • [10] A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems
    Mohammed Nahidh
    Yassir A. Yassir
    Maria Maddalena Marrapodi
    Marco Di Blasio
    Vincenzo Ronsivalle
    Marco Cicciù
    Giuseppe Minervini
    BMC Oral Health, 24