A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems

被引:0
|
作者
Nahidh, Mohammed [1 ]
Yassir, Yassir A. [1 ]
Marrapodi, Maria Maddalena [2 ]
Di Blasio, Marco [3 ]
Ronsivalle, Vincenzo [4 ]
Cicciu, Marco [4 ]
Minervini, Giuseppe [5 ,6 ]
机构
[1] Univ Baghdad, Coll Dent, Dept Orthodont, Baghdad, Iraq
[2] Univ Campania Luigi Vanvitelli, Dept Woman Child & Gen & Specialist Surg, I-80121 Naples, Italy
[3] Univ Parma, Univ Ctr Dent, Dept Med & Surg, I-43126 Parma, Italy
[4] Catania Univ, Dept Biomed & Surg & Biomed Sci, I-95123 Catania, Italy
[5] Saveetha Univ, Saveetha Inst Med & Tech Sci SIMATS, Saveetha Dent Coll & Hosp, Chennai, Tamil Nadu, India
[6] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Odontostomatol S, I-80121 Naples, Italy
关键词
Slot dimensions; Orthodontic brackets; Fixed orthodontic appliance; Orthodontics; Torque; TORQUE EXPRESSION; DIMENSIONS; MORPHOLOGY; IMPLANT; TEETH; SIZE;
D O I
10.1186/s12903-023-03841-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveOne of the most imprortant factors in achieving ideal teeth positions is the precision of the slot dimensions of orthodontic brackets into the archwires are inserted.This study aimed to assess the accuracy of the dimensions of orthodontic bracket slots and molar buccal tube apertures and to compare them with the specifications provided by the manufacturers.MethodA total of sixty brackets and ten molar buccal tubes with varying slot heights were examined using a scanning electron microscope from the mesial side. The dimensions and morphology of these bracket slots and buccal tubes apertures were assessed using the AutoCAD Software. A one-sample t-test was conducted to compare the measurements with the values provided by the manufacturer.ResultsThe findings of the present study indicated that the height of the measured bracket slots and buccal tube apertures dimensions were significantly larger than the actual dimensions and exhibiting divergent walls. On the other hand, the depth of the brackets slots showed significantly smaller values than the actual one.ConclusionA need for careful consideration when selecting a commercially accessible brand for everyday use is essential as certain materials may not meet acceptable standards.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems
    Mohammed Nahidh
    Yassir A. Yassir
    Maria Maddalena Marrapodi
    Marco Di Blasio
    Vincenzo Ronsivalle
    Marco Cicciù
    Giuseppe Minervini
    BMC Oral Health, 24
  • [2] Morphological investigation of various orthodontic lingual bracket slots using scanning electron microscopy and atomic force microscopy
    Choi, Samjin
    Kim, Jae-Hyung
    Kim, Nam-Joon
    Lee, Seung-Hoon
    Kim, Hyunsoo
    Kim, Kyung-A
    Park, Ki-Ho
    Park, Young-Guk
    MICROSCOPY RESEARCH AND TECHNIQUE, 2016, 79 (12) : 1193 - 1199
  • [3] INVESTIGATION OF ORTHODONTIC WIRES BY SCANNING ELECTRON-MICROSCOPY AND AUGER-ELECTRON SPECTROSCOPY
    CIPRUS, V
    PIRS, J
    POMENIC, L
    KERN, M
    PRACEK, B
    VACUUM, 1992, 43 (5-7) : 613 - 615
  • [4] INVESTIGATION OF ELECTRON-OPTICAL SYSTEMS BY SCANNING ELECTRON MICROSCOPY
    WELLS, OC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (09): : 1246 - &
  • [5] Scanning electron microscopy evaluation of the interface of three adhesive systems
    Macari, S
    Nonaka, T
    Gonçalves, M
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B163 - B163
  • [6] Scanning electron microscopy evaluation of the interface of three adhesive systems.
    Macari, S
    Monaka, T
    Gonçalves, M
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B207 - B207
  • [7] Surfaces of orthodontic wires - Hardness and scanning electron microscopy.
    Hintz, J
    Dhuru, V
    Fournelle, R
    Chada, S
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1463 - 1463
  • [8] Bond strength comparison and scanning electron microscopic evaluation of three orthodontic bonding systems
    Iijima, Masahiro
    Ito, Shuichi
    Yuasa, Toshihiro
    Muguruma, Takeshi
    Saito, Takashi
    Mizoguchi, Itaru
    DENTAL MATERIALS JOURNAL, 2008, 27 (03) : 392 - 399
  • [9] Effect of Different Bracket Prescriptions on Orthodontic Treatment Outcomes Measured by Three-dimensional Scanning
    Soboku, Tomohiro
    Motegi, Etsuko
    Sueishi, Kenji
    BULLETIN OF TOKYO DENTAL COLLEGE, 2019, 60 (02): : 69 - 80
  • [10] Investigation of plaque formation by scanning electron microscopy
    Koparal, Ece
    Tutuncu, Rengin
    Turkish Journal of Medical Sciences, 2000, 30 (02) : 119 - 124