A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems

被引:0
|
作者
Nahidh, Mohammed [1 ]
Yassir, Yassir A. [1 ]
Marrapodi, Maria Maddalena [2 ]
Di Blasio, Marco [3 ]
Ronsivalle, Vincenzo [4 ]
Cicciu, Marco [4 ]
Minervini, Giuseppe [5 ,6 ]
机构
[1] Univ Baghdad, Coll Dent, Dept Orthodont, Baghdad, Iraq
[2] Univ Campania Luigi Vanvitelli, Dept Woman Child & Gen & Specialist Surg, I-80121 Naples, Italy
[3] Univ Parma, Univ Ctr Dent, Dept Med & Surg, I-43126 Parma, Italy
[4] Catania Univ, Dept Biomed & Surg & Biomed Sci, I-95123 Catania, Italy
[5] Saveetha Univ, Saveetha Inst Med & Tech Sci SIMATS, Saveetha Dent Coll & Hosp, Chennai, Tamil Nadu, India
[6] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Odontostomatol S, I-80121 Naples, Italy
关键词
Slot dimensions; Orthodontic brackets; Fixed orthodontic appliance; Orthodontics; Torque; TORQUE EXPRESSION; DIMENSIONS; MORPHOLOGY; IMPLANT; TEETH; SIZE;
D O I
10.1186/s12903-023-03841-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveOne of the most imprortant factors in achieving ideal teeth positions is the precision of the slot dimensions of orthodontic brackets into the archwires are inserted.This study aimed to assess the accuracy of the dimensions of orthodontic bracket slots and molar buccal tube apertures and to compare them with the specifications provided by the manufacturers.MethodA total of sixty brackets and ten molar buccal tubes with varying slot heights were examined using a scanning electron microscope from the mesial side. The dimensions and morphology of these bracket slots and buccal tubes apertures were assessed using the AutoCAD Software. A one-sample t-test was conducted to compare the measurements with the values provided by the manufacturer.ResultsThe findings of the present study indicated that the height of the measured bracket slots and buccal tube apertures dimensions were significantly larger than the actual dimensions and exhibiting divergent walls. On the other hand, the depth of the brackets slots showed significantly smaller values than the actual one.ConclusionA need for careful consideration when selecting a commercially accessible brand for everyday use is essential as certain materials may not meet acceptable standards.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] INTERNAL INVESTIGATION OF MICROCHANNEL PLATES BY SCANNING ELECTRON-MICROSCOPY
    POLAERT, R
    RODIERE, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (10): : 1531 - 1536
  • [32] CARBONISATION OF POLYVINYLIDENE CHLORIDE - AN INVESTIGATION USING SCANNING ELECTRON MICROSCOPY
    BOULT, EH
    CAMPBELL, HG
    MARSH, H
    CARBON, 1969, 7 (06) : 700 - &
  • [33] Investigation of viability of plant tissue in the environmental scanning electron microscopy
    Tao Zheng
    K. W. Waldron
    Athene M. Donald
    Planta, 2009, 230 : 1105 - 1113
  • [34] APPLICATION OF SCANNING ELECTRON-MICROSCOPY TECHNIQUE FOR INVESTIGATION OF FERROELECTRICS
    ARISTOV, VV
    KOKHANCHIK, LS
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1988, 52 (08): : 1636 - 1640
  • [35] Scanning electron microscopy investigation of laser ablated oxide targets
    Craciun, V
    Craciun, D
    Bunescu, MC
    Dabu, R
    Boyd, IW
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (12) : 1306 - 1312
  • [36] Investigation of viability of plant tissue in the environmental scanning electron microscopy
    Zheng, Tao
    Waldron, K. W.
    Donald, Athene M.
    PLANTA, 2009, 230 (06) : 1105 - 1113
  • [37] FACTORS INFLUENCING THE PRECISION OF QUANTITATIVE SCANNING-TRANSMISSION ELECTRON-MICROSCOPY
    MULLER, SA
    GOLDIE, KN
    BURKI, R
    HARING, R
    ENGEL, A
    ULTRAMICROSCOPY, 1992, 46 (1-4) : 317 - 334
  • [38] Validation of three-dimensional surface characterising methods:: Scanning electron microscopy and confocal laser scanning microscopy
    Al-Nawas, B
    Grötz, KA
    Götz, H
    Heinrich, G
    Rippin, G
    Stender, E
    Duschner, H
    Wagner, W
    SCANNING, 2001, 23 (04) : 227 - 231
  • [39] Ultrastructural investigation of mouse sperm using atomic force microscopy and scanning electron microscopy
    Cho, S. J.
    Choi, S. K.
    Jeon, K. P.
    Gye, M. C.
    INTERNATIONAL JOURNAL OF ANDROLOGY, 2005, 28 : 35 - 35
  • [40] Early root alterations after orthodontic force application studied by light and scanning electron microscopy
    Mavragani, M
    Amundsen, OC
    Selliseth, NJ
    Brudvik, P
    Selvig, KA
    EUROPEAN JOURNAL OF ORTHODONTICS, 2004, 26 (02) : 119 - 128