Scanning electron microscopy analysis of metallic and aesthetic bracket meshes before and after debonding

被引:0
|
作者
Rodriguez-Chavez, Jacqueline Adelina [1 ]
Flores-Ruiz, Hugo Marcelo [2 ]
Flores-Ledesma, Abigailt [3 ]
Garcia-Perez, Alvaro [4 ]
Bazan-Diaz, Lourdes [5 ]
机构
[1] Univ Guadalajara, Univ Ctr Hlth Sci, Inst Dent Res, Dept Integral Dent Clin, Guadalajara, Mexico
[2] Univ Guadalajara, CUValles, Dept Nat & Exact Sci, Ameca, Mexico
[3] Meritorious Autonomous Univ Puebla, Lab Dent Mat & Biomat, Puebla, Mexico
[4] Natl Autonomous Univ Mexico UNAM, Lab Publ Hlth Res, Tlalnepantla, Mexico
[5] Univ Nacl Autonoma Mexico, Mat Res Inst, Mexico City, Mexico
关键词
Bracket; Adhesive; Shear bond strength; Scanning electron microscopy; SHEAR BOND STRENGTH; CERAMIC BRACKETS; BASE DESIGN;
D O I
10.4041/kjod24.073
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To study the influence of bracket base meshes on shear bond strength and observe them using a scanning electron microscopy (SEM) before and after debonding. Methods: Ninety brackets were divided into nine groups Series Flexx 2G (R). Groups G1 to G6 and G7 to G9 consisted of metallic and aesthetic brackets, respectively. Initial photographs of all brackets were taken through SEM at 25X magnification. The brackets were then bonded to premolars using TransbondTM XT, and a shear bond strength test was conducted after 24 hours using an Instron machine at 1 mm/min. After debonding, the bracket meshes were observed using SEM. Results: Before bonding, 72.22% of brackets didn't present mesh defects, while 27.77% did. SEM analysis revealed that G4 and G5 presented defects in 100%, G7 in 40%, and G8 in 10%. The average shear bond strength of 9.67 +/- 2.84 MPa and 11.21 +/- 4.99 MPa were obtained for both metallic and aesthetic brackets, respectively. A Pairwise-Wilcoxon test with Benjamini-Hochberg correction was conducted to determine specific statistical differences between the groups, revealing significant differences based on bracket type and shear bond strength (P < 0.009). Conclusions: This study suggested that the shape of bracket meshes influenced shear bond strength.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [11] EXAMINATION OF MUCOSAL SURFACES BY SCANNING ELECTRON-MICROSCOPY BEFORE AND AFTER REMOVAL OF DEBRIS
    DICKSON, GR
    MCKENNA, S
    MCCOLL, K
    CARR, KE
    JOURNAL OF MICROSCOPY, 1989, 153 : 75 - 79
  • [12] A Novel Method Using Confocal Laser Scanning Microscopy for Three-Dimensional Analysis of Human Dental Enamel Subjected to Ceramic Bracket Debonding
    Ferreira, Fabiano G.
    da Silva, Eduardo M.
    Vilella, Oswaldo de V.
    MICROSCOPY AND MICROANALYSIS, 2020, 26 (05) : 1053 - 1060
  • [13] Influence of Three Types of Abutments on Preload Values Before and After Cyclic Loading with Structural Analysis by Scanning Electron Microscopy
    Butignon, Luis Eduardo
    Basilio, Mariana de Almeida
    Pereira, Rodrigo de Paula
    Arioli Filho, Joao Neudenir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : E161 - E170
  • [14] Contribution of environmental scanning electron microscopy to the characterization of metallic materials
    Oudet, F
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 2003, 100 (05): : 561 - +
  • [15] Morphological investigation of various orthodontic lingual bracket slots using scanning electron microscopy and atomic force microscopy
    Choi, Samjin
    Kim, Jae-Hyung
    Kim, Nam-Joon
    Lee, Seung-Hoon
    Kim, Hyunsoo
    Kim, Kyung-A
    Park, Ki-Ho
    Park, Young-Guk
    MICROSCOPY RESEARCH AND TECHNIQUE, 2016, 79 (12) : 1193 - 1199
  • [16] SCANNING ELECTRON MICROSCOPY OF ERYTHROCYTES AFTER MICROTHROMBOSIS
    BARNHART, MI
    WHITE, BC
    FEDERATION PROCEEDINGS, 1970, 29 (02) : A648 - +
  • [17] Correlation between dental enamel chemical composition and bracket debonding, comparing adhesive systems through a scanning electron microscope
    Adelina Rodriguez-Chavez, Jacqueline
    Angel Arenas-Alatorre, Jesus
    Flores-Ruiz, Hugo M.
    Javier Aguilar-Perez, Fernando
    Flores-Ledesma, Abigailt
    Abnoba Moreno-Vargas, Yoshamin
    Pesqueira-Melgarejo, Roberto
    MICROSCOPY RESEARCH AND TECHNIQUE, 2022, 85 (07) : 2567 - 2578
  • [18] Scanning electron microscopy of the undersurface of cell monolayers grown on metallic implants
    Institute of Biological Sciences, The University of Wales, Aberystwyth, United Kingdom
    J. MATER. SCI. MATER. MED., 2 (120-124):
  • [19] Ultrastructure of the Tongue of the German Mast Goose (Anser anser) by Scanning Electron Microscopy Before and After Plastination
    Baygeldi, Saime Betul
    Guzel, Baris Can
    Ilgun, Ramazan
    Ozkan, Zait Ender
    PAKISTAN JOURNAL OF ZOOLOGY, 2023, 55 (06) : 2677 - 2682
  • [20] Analysis of enamel surface roughness after different adhesive removal techniques for orthodontic bracket debonding
    Palmer J.A.
    Mang T.
    Tabbaa S.
    Al-Jewair T.
    Lasers in Dental Science, 2018, 2 (2) : 95 - 101