Scanning electron microscopy analysis of metallic and aesthetic bracket meshes before and after debonding

被引:0
|
作者
Rodriguez-Chavez, Jacqueline Adelina [1 ]
Flores-Ruiz, Hugo Marcelo [2 ]
Flores-Ledesma, Abigailt [3 ]
Garcia-Perez, Alvaro [4 ]
Bazan-Diaz, Lourdes [5 ]
机构
[1] Univ Guadalajara, Univ Ctr Hlth Sci, Inst Dent Res, Dept Integral Dent Clin, Guadalajara, Mexico
[2] Univ Guadalajara, CUValles, Dept Nat & Exact Sci, Ameca, Mexico
[3] Meritorious Autonomous Univ Puebla, Lab Dent Mat & Biomat, Puebla, Mexico
[4] Natl Autonomous Univ Mexico UNAM, Lab Publ Hlth Res, Tlalnepantla, Mexico
[5] Univ Nacl Autonoma Mexico, Mat Res Inst, Mexico City, Mexico
关键词
Bracket; Adhesive; Shear bond strength; Scanning electron microscopy; SHEAR BOND STRENGTH; CERAMIC BRACKETS; BASE DESIGN;
D O I
10.4041/kjod24.073
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To study the influence of bracket base meshes on shear bond strength and observe them using a scanning electron microscopy (SEM) before and after debonding. Methods: Ninety brackets were divided into nine groups Series Flexx 2G (R). Groups G1 to G6 and G7 to G9 consisted of metallic and aesthetic brackets, respectively. Initial photographs of all brackets were taken through SEM at 25X magnification. The brackets were then bonded to premolars using TransbondTM XT, and a shear bond strength test was conducted after 24 hours using an Instron machine at 1 mm/min. After debonding, the bracket meshes were observed using SEM. Results: Before bonding, 72.22% of brackets didn't present mesh defects, while 27.77% did. SEM analysis revealed that G4 and G5 presented defects in 100%, G7 in 40%, and G8 in 10%. The average shear bond strength of 9.67 +/- 2.84 MPa and 11.21 +/- 4.99 MPa were obtained for both metallic and aesthetic brackets, respectively. A Pairwise-Wilcoxon test with Benjamini-Hochberg correction was conducted to determine specific statistical differences between the groups, revealing significant differences based on bracket type and shear bond strength (P < 0.009). Conclusions: This study suggested that the shape of bracket meshes influenced shear bond strength.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [21] TRIBOLOGICAL PROPERTIES OF DENTAL ENAMEL BEFORE AND AFTER ORTHODONTIC BRACKET BONDING-DEBONDING BY NANO-SCRATCH TEST
    Karimzadeh, A.
    Ayatollahi, M. R.
    Nik, T. Hosseinzadeh
    JOURNAL OF MECHANICS, 2019, 35 (02) : 279 - 287
  • [22] SCANNING ELECTRON MICROSCOPY ANALYSIS OF DENTAL CEMENTS
    Radosavljevic, Radivoje D.
    Stankovic, Sasa D.
    Ajdukovic, Zorica R.
    Jevremovic, Danimir P.
    Todic, Jelena T.
    HEMIJSKA INDUSTRIJA, 2009, 63 (04) : 281 - 288
  • [23] DEVICE FAILURE ANALYSIS BY SCANNING ELECTRON MICROSCOPY
    THORNTON, PR
    DAVIES, IG
    SHAW, DA
    SULWAY, DV
    WAYTE, RC
    MICROELECTRONICS RELIABILITY, 1969, 8 (01) : 33 - &
  • [24] Morphological analysis of cells by scanning electron microscopy
    Kim, Yu Jin
    Kim, Hee-Dae
    Park, Chanhyuk
    Park, Taeyoung
    Kim, Jaewan
    Choi, Young Jin
    Kim, Yong-Sang
    Lee, Kun Ho
    Kang, Chi Jung
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (02) : 1325 - 1328
  • [25] STEREOLOGICAL ANALYSIS IN SCANNING ELECTRON-MICROSCOPY
    SCHMEISSER, H
    MICROSCOPICA ACTA, 1979, 82 (02): : 129 - 136
  • [26] Scanning electron microscopy in analysis of urinary stones
    Racek, Martin
    Racek, Jaroslav
    Hupakova, Ivana
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2019, 79 (03): : 208 - 217
  • [27] Analysis of the Attachments Wear with Scanning Electron Microscopy
    Pinto, Antonio Correia
    Mendes, Jose Manuel
    Angeja, Antonio Ferreira
    Coelho, Jose Alberto
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2008, 49 (01): : 13 - 18
  • [28] Analysis of Probe Current in Scanning Electron Microscopy
    Lim, Sun-Jong
    Lee, Chan-Hong
    2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 1037 - 1040
  • [29] FAILURE ANALYSIS OF MICROCIRCUITRY BY SCANNING ELECTRON MICROSCOPY
    THORNTON, PR
    HUGHES, KA
    KYAW, H
    MILLWARD, C
    SULWAY, DV
    MICROELECTRONICS RELIABILITY, 1967, 6 (01) : 9 - &
  • [30] Scanning electron microscopy analysis of non-metallic inclusions for making steels with superior mechanical properties
    Riyahi Malayeri, Kamrooz
    IRONMAKING & STEELMAKING, 2024, 51 (04) : 307 - 315