Analysis of Aperture-based Complexity Metrics and Their Effect on Patient-specific Quality Assurance in Intensity-modulated Radiation Therapy Planning

被引:0
|
作者
Saroj, Dinesh Kumar [1 ,2 ]
Yadav, Suresh [3 ]
Paliwal, Neetu [2 ]
Shende, Ravindra Bhagwat [1 ]
Gupta, Gaurav [1 ]
机构
[1] BALCO Med Ctr, Unit Vedanta Med Res Fdn, Dept Radiotherapy, New Raipur 493661, Chhattisgarh, India
[2] Rabindranath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[3] Gandhi Med Coll, Dept Radiat Oncol, Bhopal, Madhya Pradesh, India
关键词
Gamma passing rate; intensity-modulated radiation therapy; modulation complexity score; patient-specific quality assurance; receiver operating characteristic curve; IMRT;
D O I
10.4103/jmp.jmp_195_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:Identifying plans at risk of patient-specific quality assurance (PSQA) failure through complexity metrics can reduce the workload while maintaining quality. This study evaluates complexity metrics as predictors of PSQA outcomes.Materials and Methods:A retrospective analysis was conducted on 192 IMRT plans for head-and-neck cancer. Complexity metrics were calculated using an in-house Python program. PSQA was performed with 3%/2-mm gamma passing rate (GPR) criteria, with plans classified as "Pass" (GPR >= 95%) or "Fail." Statistical analyses, including Spearman's correlation and receiver operating characteristic analysis, assessed the metrics' predictive value.Results:Passing plans had an average GPR of 98.64 +/- 1.33%, compared to 92.17 +/- 2.35% for failing plans. The mean small area segment (MSAS) 5mm metric, with a threshold of 0.085, achieved a true positive rate of 38.17% and a false positive rate of 3.1%. Beam modulation and beam area indices also significantly differed between passing and failing plans.Conclusion:MSAS5 and edge metrics showed strong potential for identifying high-risk plans. These metrics can guide targeted PSQA, improving workflow efficiency without compromising treatment safety.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [11] An aperture-based inverse planning algorithm for modulated electron radiation therapy
    Jiang, SB
    Pawlicki, T
    Ma, CM
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 116 - 118
  • [12] Comparison of patient-specific intensity modulated radiation therapy quality assurance for the prostate across multiple institutions
    Kubo, Kazuki
    Monzen, Hajime
    Shimomura, Kohei
    Matsumoto, Kenji
    Sato, Tomoharu
    Tamura, Mikoto
    Nakamatsu, Kiyoshi
    Ishii, Kentaro
    Kawamorita, Ryu
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (06) : 600 - 605
  • [13] Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
    Mancuso, Gordon M.
    Fontenot, Jonas D.
    Gibbons, John P.
    Parker, Brent C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4378 - 4385
  • [14] RE: Multicentre quality assurance of intensity-modulated radiation therapy planning: Beware the benchmarker
    Williams, M. J.
    Bailey, M. J.
    Forstner, D.
    Metcalfe, P. E.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (03): : 303 - 303
  • [15] A Survey of Quality Assurance in Intensity-Modulated Radiation Therapy in Japan
    Nakamura, M.
    Ono, T.
    Akimoto, M.
    Mukumoto, N.
    Ishihara, Y.
    Utsunomiya, S.
    Shiinoki, T.
    Miyabe, Y.
    Sato, S.
    Monzen, H.
    Hiraoka, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [16] Toward automated quality assurance for intensity-modulated radiation therapy
    Low, DA
    Dempsey, JF
    Markman, J
    Mutic, S
    Klein, EE
    Sohn, JW
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02): : 443 - 452
  • [17] Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study
    Oh, Se An
    Kim, Sung Yeop
    Park, Jaehyeon
    Park, Jae Won
    Yea, Ji Woon
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2022, 39 (02): : 108 - 115
  • [18] Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy
    Noriyuki Kadoya
    Kota Abe
    Hikaru Nemoto
    Kiyokazu Sato
    Yoshiro Ieko
    Kengo Ito
    Suguru Dobashi
    Ken Takeda
    Keiichi Jingu
    Radiological Physics and Technology, 2019, 12 : 351 - 356
  • [19] Quick, efficient and effective patient-specific intensity-modulated radiation therapy quality assurance using log file and electronic portal imaging device
    Kumar, Rajesh
    Amols, H. I.
    Lovelock, M.
    Sharma, S. D.
    Datta, D.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (02) : 297 - 303
  • [20] Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
    Basavatia, Amar K.
    Fiedler, Derek A.
    Ritter, Johannes
    Brodin, Patrik
    Goddard, Lee C.
    Jeong, Kyoungkeun
    Hsu, Shu-Hui
    Mynampati, Dinesh K.
    Yaparpalvi, Ravindra
    Tome, Wolfgang A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (05)