Analysis of Aperture-based Complexity Metrics and Their Effect on Patient-specific Quality Assurance in Intensity-modulated Radiation Therapy Planning

被引:0
|
作者
Saroj, Dinesh Kumar [1 ,2 ]
Yadav, Suresh [3 ]
Paliwal, Neetu [2 ]
Shende, Ravindra Bhagwat [1 ]
Gupta, Gaurav [1 ]
机构
[1] BALCO Med Ctr, Unit Vedanta Med Res Fdn, Dept Radiotherapy, New Raipur 493661, Chhattisgarh, India
[2] Rabindranath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[3] Gandhi Med Coll, Dept Radiat Oncol, Bhopal, Madhya Pradesh, India
关键词
Gamma passing rate; intensity-modulated radiation therapy; modulation complexity score; patient-specific quality assurance; receiver operating characteristic curve; IMRT;
D O I
10.4103/jmp.jmp_195_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:Identifying plans at risk of patient-specific quality assurance (PSQA) failure through complexity metrics can reduce the workload while maintaining quality. This study evaluates complexity metrics as predictors of PSQA outcomes.Materials and Methods:A retrospective analysis was conducted on 192 IMRT plans for head-and-neck cancer. Complexity metrics were calculated using an in-house Python program. PSQA was performed with 3%/2-mm gamma passing rate (GPR) criteria, with plans classified as "Pass" (GPR >= 95%) or "Fail." Statistical analyses, including Spearman's correlation and receiver operating characteristic analysis, assessed the metrics' predictive value.Results:Passing plans had an average GPR of 98.64 +/- 1.33%, compared to 92.17 +/- 2.35% for failing plans. The mean small area segment (MSAS) 5mm metric, with a threshold of 0.085, achieved a true positive rate of 38.17% and a false positive rate of 3.1%. Beam modulation and beam area indices also significantly differed between passing and failing plans.Conclusion:MSAS5 and edge metrics showed strong potential for identifying high-risk plans. These metrics can guide targeted PSQA, improving workflow efficiency without compromising treatment safety.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [41] Inverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
    Lee, Jeong-Woo
    Park, Jeong-Hoon
    Chung, Jin-Beom
    Park, Ji-Yeon
    Choe, Bo-Young
    Suh, Tae-Suk
    Lee, Doo-Hyun
    Hong, Semie
    Kang, Min-Young
    Choi, Kyoung-Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1649 - 1656
  • [42] A software system for patient-specific quality control of intensity-modulated radiation treatments by Fricke-gel dosimetry
    Belanger, P
    Bercier, Y
    Parker, W
    Hristov, D
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 394 - 396
  • [43] A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans
    Li, Guangjun
    Wu, Kui
    Peng, Guang
    Zhang, Yingjie
    Bai, Sen
    MEDICAL DOSIMETRY, 2014, 39 (04) : 309 - 313
  • [44] Treatment Plan Complexity Quantification for Predicting Patient-Specific Quality Assurance of Stereotactic Volumetric Modulated Arc Therapy
    Xudong, X.
    Ding, Y.
    Wei, W.
    Ma, C.
    Wang, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E286 - E287
  • [45] Multicentre quality assurance of intensity-modulated radiation therapy plans: A precursor to clinical trials
    Williams, M. J.
    Bailey, M. J.
    Forstner, D.
    Metcalfe, P. E.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (05): : 472 - 479
  • [46] Improving intensity-modulated radiation therapy quality assurance by adopting statistical process control
    Cui, T.
    Peng, J-X
    Jin, X-L
    Chu, X-G
    Zhang, J.
    Cui, L-Z
    Xing, X-F
    CANCER RADIOTHERAPIE, 2022, 26 (03): : 427 - 432
  • [47] Development and Evaluation of Multipurpose Phantom for Delivery Quality Assurance of Intensity-modulated Radiation Therapy
    Jang, Jae-Uk
    Han, Man-Seok
    Kim, Ki-Hwan
    Jeon, Min-Cheol
    Hwang, Ui-Jung
    JOURNAL OF MAGNETICS, 2022, 27 (04) : 430 - 439
  • [48] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    ChineseJournalofBiomedicalEngineering, 2015, 24 (02) : 58 - 65
  • [49] Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy
    Tsai, Jen-San
    Micaily, Bizhan
    Miyamoto, Curtis
    MEDICAL DOSIMETRY, 2012, 37 (03) : 321 - 333
  • [50] Template-based Intensity-Modulated Radiation Therapy: A Cost-effective Intensity-Modulated Radiation Therapy Planning Procedure for Prostate Cancer
    Cao, Fred
    Ramaseshan, Ramani
    Cooper, Nancy
    Elith, Craig A.
    Nuraney, Nimet
    Steiner, Peter
    Agranovich, Alex
    Kwan, Winkle
    Liu, Mitchell
    Po, Milton
    Karvat, Anand
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (03) : 325 - 330