Analysis of Aperture-based Complexity Metrics and Their Effect on Patient-specific Quality Assurance in Intensity-modulated Radiation Therapy Planning

被引:0
|
作者
Saroj, Dinesh Kumar [1 ,2 ]
Yadav, Suresh [3 ]
Paliwal, Neetu [2 ]
Shende, Ravindra Bhagwat [1 ]
Gupta, Gaurav [1 ]
机构
[1] BALCO Med Ctr, Unit Vedanta Med Res Fdn, Dept Radiotherapy, New Raipur 493661, Chhattisgarh, India
[2] Rabindranath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[3] Gandhi Med Coll, Dept Radiat Oncol, Bhopal, Madhya Pradesh, India
关键词
Gamma passing rate; intensity-modulated radiation therapy; modulation complexity score; patient-specific quality assurance; receiver operating characteristic curve; IMRT;
D O I
10.4103/jmp.jmp_195_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:Identifying plans at risk of patient-specific quality assurance (PSQA) failure through complexity metrics can reduce the workload while maintaining quality. This study evaluates complexity metrics as predictors of PSQA outcomes.Materials and Methods:A retrospective analysis was conducted on 192 IMRT plans for head-and-neck cancer. Complexity metrics were calculated using an in-house Python program. PSQA was performed with 3%/2-mm gamma passing rate (GPR) criteria, with plans classified as "Pass" (GPR >= 95%) or "Fail." Statistical analyses, including Spearman's correlation and receiver operating characteristic analysis, assessed the metrics' predictive value.Results:Passing plans had an average GPR of 98.64 +/- 1.33%, compared to 92.17 +/- 2.35% for failing plans. The mean small area segment (MSAS) 5mm metric, with a threshold of 0.085, achieved a true positive rate of 38.17% and a false positive rate of 3.1%. Beam modulation and beam area indices also significantly differed between passing and failing plans.Conclusion:MSAS5 and edge metrics showed strong potential for identifying high-risk plans. These metrics can guide targeted PSQA, improving workflow efficiency without compromising treatment safety.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [31] Investigating the Importance of Phantom Geometry in Intensity-Modulated Radiation Therapy Quality Assurance
    Hamilton, B.
    Langner, U.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Intensity-modulated radiation therapy -: Quality assurance with the mutual information index (MI)
    Brendemuehl, Astrid
    Ostrowitzki, Stefan
    Altenburger, Uwe
    Haller, J. Christoph
    Ruhlmann, Juegen
    Buzug, Thorsten M.
    Advances in Medical Engineering, 2007, 114 : 205 - 210
  • [33] The Least-Intensity Feasible Solution for Aperture-Based Inverse Planning in Radiation Therapy
    Y. Xiao
    D. Michalski
    J.M. Galvin
    Y. Censor
    Annals of Operations Research, 2003, 119 : 183 - 203
  • [34] Sensitivity of Three Patient-Specific Quality Assurance Systems to MLC Aperture Errors With Volumetric Modulated Arc Therapy
    Hu, Jinyou
    Gu, Shaoxian
    Wang, Ningyu
    Cui, Fengjie
    Zhang, Shengyuan
    Yin, Chuou
    Cai, Yunzhu
    Gou, Chengjun
    Zou, Lian
    Wu, Zhangwen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [35] Statistical process control analysis for patient quality assurance of intensity modulated radiation therapy
    Rena Lee
    Kyubo Kim
    Samju Cho
    Sangwook Lim
    Suk Lee
    Jang Bo Shim
    Hyun Do Huh
    Sang Hoon Lee
    Sohyun Ahn
    Journal of the Korean Physical Society, 2017, 71 : 717 - 721
  • [36] Statistical process control analysis for patient quality assurance of intensity modulated radiation therapy
    Lee, Rena
    Kim, Kyubo
    Cho, Samju
    Lim, Sangwook
    Lee, Suk
    Shim, Jang Bo
    Huh, Hyun Do
    Lee, Sang Hoon
    Ahn, Sohyun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (10) : 717 - 721
  • [37] Patient-specific quality assurance for intensity-modulated dynamic tumor-tracking radiotherapy with Vero4DRT
    Mukumoto, N.
    Nakamura, M.
    Yamada, M.
    Takahashi, K.
    Miyabe, Y.
    Nakamura, A.
    Itasaka, S.
    Mizowaki, T.
    Kokubo, M.
    Hiraoka, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S89 - S89
  • [38] Evaluation of dosimetric advantages of using patient-specific aperture system with intensity-modulated proton therapy for the shallow depth tumor
    Yasui, Keisuke
    Toshito, Toshiyuki
    Omachi, Chihiro
    Hayashi, Kensuke
    Tanaka, Kenichiro
    Asai, Kumiko
    Shimomura, Akira
    Muramatsu, Rie
    Hayashi, Naoki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 132 - 137
  • [39] Error Detection in Intensity-Modulated Radiation Therapy Quality Assurance Using Radiomic Analysis of Gamma Distributions
    Wootton, Landon S.
    Nyflot, Matthew J.
    Chaovalitwongse, W. Art
    Ford, Eric
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (01): : 219 - 228
  • [40] Forecasting model for qualitative prediction of the results of patient-specific quality assurance based on planning and complexity metrics and their interrelations. Pilot study
    Piotrowski, Tomasz
    Ryczkowski, Adam
    Kalendralis, Petros
    Adamczewski, Marcin
    Sadowski, Piotr
    Bajon, Barbara
    Kruszyna-Mochalska, Marta
    Jodda, Agata
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (03) : 318 - 328